一例严重电热环烧伤病例及一种治疗方法

IF 0.1 Q4 SURGERY Turkish Journal of Plastic Surgery Pub Date : 2022-07-01 DOI:10.4103/tjps.tjps_8_22
B. Ozkan, Abbas Albayati, S. Savran, C. Uysal
{"title":"一例严重电热环烧伤病例及一种治疗方法","authors":"B. Ozkan, Abbas Albayati, S. Savran, C. Uysal","doi":"10.4103/tjps.tjps_8_22","DOIUrl":null,"url":null,"abstract":"Ring-associated burns are infrequent comprising only a tiny fraction of burn consults. Due to the circular nature of rings, these burns are often circumferential, with an increased risk for compartment syndrome and neurovascular injury. The severity of ring burn is related to the type of material and electrical current. Low-voltage injuries are generally due to contact with batteries and household devices, while high-voltage electric injuries occur with occupation-related accidents or natural disasters. Low-voltage ring burn can be managed conservatively with close follow-up. However, high-voltage ring burn might have dramatic consequences such as finger amputation. To date, there have been few cases reported in the literature of a ring burn. Most cases were superficial burns and managed with secondary healing or skin grafting. However, the literature has not reported the management of a severe ring burn with deteriorated finger circulation. In this case report, we present a circumferential electrothermal ring burn case with resulted in total loss of a finger. Furthermore, we propose an algorithmic approach to ring burn injuries.","PeriodicalId":42065,"journal":{"name":"Turkish Journal of Plastic Surgery","volume":null,"pages":null},"PeriodicalIF":0.1000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A severe electrothermal ring burn case and a proposed treatment algorithm\",\"authors\":\"B. Ozkan, Abbas Albayati, S. Savran, C. Uysal\",\"doi\":\"10.4103/tjps.tjps_8_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ring-associated burns are infrequent comprising only a tiny fraction of burn consults. Due to the circular nature of rings, these burns are often circumferential, with an increased risk for compartment syndrome and neurovascular injury. The severity of ring burn is related to the type of material and electrical current. Low-voltage injuries are generally due to contact with batteries and household devices, while high-voltage electric injuries occur with occupation-related accidents or natural disasters. Low-voltage ring burn can be managed conservatively with close follow-up. However, high-voltage ring burn might have dramatic consequences such as finger amputation. To date, there have been few cases reported in the literature of a ring burn. Most cases were superficial burns and managed with secondary healing or skin grafting. However, the literature has not reported the management of a severe ring burn with deteriorated finger circulation. In this case report, we present a circumferential electrothermal ring burn case with resulted in total loss of a finger. Furthermore, we propose an algorithmic approach to ring burn injuries.\",\"PeriodicalId\":42065,\"journal\":{\"name\":\"Turkish Journal of Plastic Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.1000,\"publicationDate\":\"2022-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Turkish Journal of Plastic Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/tjps.tjps_8_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Plastic Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/tjps.tjps_8_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

环相关性烧伤并不常见,仅占烧伤会诊的一小部分。由于环的圆形性质,这些烧伤通常是周向的,增加了筋膜室综合征和神经血管损伤的风险。环形烧伤的严重程度与材料的类型和电流有关。低压伤害通常是由于与电池和家用设备的接触,而高压伤害则发生在与职业有关的事故或自然灾害中。低压环烧伤可以保守处理,密切随访。然而,高压环烧伤可能会造成严重后果,如手指截肢。迄今为止,文献中很少有环烧伤的病例报道。大多数病例为浅表烧伤,采用二次愈合或植皮治疗。然而,文献尚未报道严重戒指烧伤伴手指循环恶化的处理方法。在这个病例报告中,我们提出了一个圆周电热环烧伤的情况下,导致一个手指的全部损失。此外,我们提出了一种环形烧伤的算法方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A severe electrothermal ring burn case and a proposed treatment algorithm
Ring-associated burns are infrequent comprising only a tiny fraction of burn consults. Due to the circular nature of rings, these burns are often circumferential, with an increased risk for compartment syndrome and neurovascular injury. The severity of ring burn is related to the type of material and electrical current. Low-voltage injuries are generally due to contact with batteries and household devices, while high-voltage electric injuries occur with occupation-related accidents or natural disasters. Low-voltage ring burn can be managed conservatively with close follow-up. However, high-voltage ring burn might have dramatic consequences such as finger amputation. To date, there have been few cases reported in the literature of a ring burn. Most cases were superficial burns and managed with secondary healing or skin grafting. However, the literature has not reported the management of a severe ring burn with deteriorated finger circulation. In this case report, we present a circumferential electrothermal ring burn case with resulted in total loss of a finger. Furthermore, we propose an algorithmic approach to ring burn injuries.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
8
审稿时长
28 weeks
期刊最新文献
Glomus tumors of the digit: A retrospective analysis of clinical and functional outcomes The effect of deferoxamine on fat graft survival in tamoxifen use: An experimental study Nasal reconstruction in a rare case of unilateral arhinia in bosma arhinia microphthalmia syndrome A complication after radiofrequency ablation: Skin necrosis Comparative analysis of speech outcomes in the treatment of velopharyngeal insufficiency: Traditional superior-based pharyngeal flap and pharyngeal flap combined with radical intravelar veloplasty
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1