金属髋关节置换术磨损建模的数学标准-参数双优化与医学物理应用

Standards Pub Date : 2021-09-07 DOI:10.3390/standards1010006
F. Casesnoves
{"title":"金属髋关节置换术磨损建模的数学标准-参数双优化与医学物理应用","authors":"F. Casesnoves","doi":"10.3390/standards1010006","DOIUrl":null,"url":null,"abstract":"Total hip metal arthroplasty (THA) constitutes an important proportion of the standard clinical hip implant usage in Medical Physics and Biomedical Engineering. A computational nonlinear optimization is performed with two commonly metal materials in Metal-on-Metal (MoM) THA. Namely, Cast Co-Cr Alloy and Titanium. The principal result is the numerical determination of the K adimensional-constant parameter of the model. Results from a new more powerful algorithm than previous contributions, show significant improvements. Numerical standard figures for dual optimization give acceptable model-parameter values with low residuals. These results are demonstrated with 2D and 3D Graphical/Interior Optimization also. According to the findings/calculations, the standard optimized metal-model parameters are mathematically proven and verified. Mathematical consequences are obtained for model improvements and in vitro simulation methodology. The wear magnitude for in vitro determinations with these model parameter data constitute the innovation of the method. In consequence, the erosion prediction for laboratory experimental testing in THA adds valuable information to the literature. Applications lead to medical physics improvements for material/metal-THA designs.","PeriodicalId":21933,"journal":{"name":"Standards","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Mathematical Standard-Parameters Dual Optimization for Metal Hip Arthroplasty Wear Modelling with Medical Physics Applications\",\"authors\":\"F. Casesnoves\",\"doi\":\"10.3390/standards1010006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Total hip metal arthroplasty (THA) constitutes an important proportion of the standard clinical hip implant usage in Medical Physics and Biomedical Engineering. A computational nonlinear optimization is performed with two commonly metal materials in Metal-on-Metal (MoM) THA. Namely, Cast Co-Cr Alloy and Titanium. The principal result is the numerical determination of the K adimensional-constant parameter of the model. Results from a new more powerful algorithm than previous contributions, show significant improvements. Numerical standard figures for dual optimization give acceptable model-parameter values with low residuals. These results are demonstrated with 2D and 3D Graphical/Interior Optimization also. According to the findings/calculations, the standard optimized metal-model parameters are mathematically proven and verified. Mathematical consequences are obtained for model improvements and in vitro simulation methodology. The wear magnitude for in vitro determinations with these model parameter data constitute the innovation of the method. In consequence, the erosion prediction for laboratory experimental testing in THA adds valuable information to the literature. Applications lead to medical physics improvements for material/metal-THA designs.\",\"PeriodicalId\":21933,\"journal\":{\"name\":\"Standards\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-09-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Standards\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/standards1010006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Standards","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/standards1010006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

全髋关节金属置换术(THA)是医学物理和生物医学工程中标准临床髋关节植入物使用的重要组成部分。在金属对金属(MoM)结构中,对两种常见的金属材料进行了非线性优化计算。即铸造钴铬合金和钛。主要结果是模型K维常数参数的数值确定。从一个新的更强大的算法比以前的贡献,显示出显着的改进。双优化的数值标准图给出了可接受的模型参数值,残差低。这些结果也在2D和3D图形/内部优化中得到了验证。根据研究结果/计算,对标准优化金属模型参数进行了数学证明和验证。得到了模型改进和体外模拟方法的数学结果。利用这些模型参数数据体外测定磨损量是该方法的创新之处。因此,对THA实验室试验测试的侵蚀预测为文献增加了有价值的信息。应用导致材料/金属tha设计的医学物理改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mathematical Standard-Parameters Dual Optimization for Metal Hip Arthroplasty Wear Modelling with Medical Physics Applications
Total hip metal arthroplasty (THA) constitutes an important proportion of the standard clinical hip implant usage in Medical Physics and Biomedical Engineering. A computational nonlinear optimization is performed with two commonly metal materials in Metal-on-Metal (MoM) THA. Namely, Cast Co-Cr Alloy and Titanium. The principal result is the numerical determination of the K adimensional-constant parameter of the model. Results from a new more powerful algorithm than previous contributions, show significant improvements. Numerical standard figures for dual optimization give acceptable model-parameter values with low residuals. These results are demonstrated with 2D and 3D Graphical/Interior Optimization also. According to the findings/calculations, the standard optimized metal-model parameters are mathematically proven and verified. Mathematical consequences are obtained for model improvements and in vitro simulation methodology. The wear magnitude for in vitro determinations with these model parameter data constitute the innovation of the method. In consequence, the erosion prediction for laboratory experimental testing in THA adds valuable information to the literature. Applications lead to medical physics improvements for material/metal-THA designs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Towards Life Cycle Assessment for the Environmental Evaluation of District Heating and Cooling: A Critical Review Towards The Development of a Governance System for Central Purchasing Body Collaboration and Performance Benefit–Risk Assessment in Sport and Recreation: Historical Development and Review of AS ISO 4980:2023 Seasonal Data Cleaning for Sales with Chase Demand Strategy Are Stakeholders’ Opinions Redundant?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1