{"title":"确定弹性表面保护系统的外壳","authors":"F. Huppertz, U. Lange","doi":"10.12900/rbm14.20.3-0020","DOIUrl":null,"url":null,"abstract":"Using the example of peel resistance of flexible polyurea coatings it could be demonstrated that additional proof of quality for coating systems do not only apply in the laboratory, but also in practice. This parameter may provide crucial additional statements on the adhesion of surface protection systems. To determine the peel resistance, a special test apparatus was developed. The test procedure could be successfully applied both in the laboratory and on coated concrete surfaces at the object. By means of the empirical comparison between the lab results and the minimum peel strength of about 1.0 N/mm found in practice at the object, this additional parameter could be derived in relation to the evaluation of the adhesion of a coating system.","PeriodicalId":20957,"journal":{"name":"Restoration of Buildings and Monuments","volume":"80 3 1","pages":"191 - 196"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Bestimmung des Schälwiderstandes von flexiblen Oberflächenschutzsystemen\",\"authors\":\"F. Huppertz, U. Lange\",\"doi\":\"10.12900/rbm14.20.3-0020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Using the example of peel resistance of flexible polyurea coatings it could be demonstrated that additional proof of quality for coating systems do not only apply in the laboratory, but also in practice. This parameter may provide crucial additional statements on the adhesion of surface protection systems. To determine the peel resistance, a special test apparatus was developed. The test procedure could be successfully applied both in the laboratory and on coated concrete surfaces at the object. By means of the empirical comparison between the lab results and the minimum peel strength of about 1.0 N/mm found in practice at the object, this additional parameter could be derived in relation to the evaluation of the adhesion of a coating system.\",\"PeriodicalId\":20957,\"journal\":{\"name\":\"Restoration of Buildings and Monuments\",\"volume\":\"80 3 1\",\"pages\":\"191 - 196\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Restoration of Buildings and Monuments\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12900/rbm14.20.3-0020\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Restoration of Buildings and Monuments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12900/rbm14.20.3-0020","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

以柔性聚脲涂层的抗剥离性为例,可以证明涂层系统的附加质量证明不仅适用于实验室,也适用于实践。该参数可以提供关于表面保护系统附着力的重要附加说明。为了测定其抗剥离性,研制了专用的试验装置。测试过程可以成功地应用于实验室和涂层混凝土表面的对象。通过实验室结果与实际中发现的最小剥离强度约1.0 N/mm之间的经验比较,可以推导出与涂层系统附着力评估相关的附加参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Bestimmung des Schälwiderstandes von flexiblen Oberflächenschutzsystemen
Using the example of peel resistance of flexible polyurea coatings it could be demonstrated that additional proof of quality for coating systems do not only apply in the laboratory, but also in practice. This parameter may provide crucial additional statements on the adhesion of surface protection systems. To determine the peel resistance, a special test apparatus was developed. The test procedure could be successfully applied both in the laboratory and on coated concrete surfaces at the object. By means of the empirical comparison between the lab results and the minimum peel strength of about 1.0 N/mm found in practice at the object, this additional parameter could be derived in relation to the evaluation of the adhesion of a coating system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Quantitative Analysis of Historic Mortars by Digital Image Analysis of Thin Sections Twelve Years of Energy Efficiency in Historic Buildings in Sweden Valuation of Medieval Churches; Taking Account of Laypersons’ Views Building Performance Evaluation – A Design Approach for Refurbishment of a Small Traditional Building in Scotland Guidance for Finding a Sustainable Balance between Energy Savings and Heritage Preservation When Retrofitting Heritage Buildings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1