热带国家储油罐防雷系统

Bryan Denov, Ilham Hendratama, R. Zoro
{"title":"热带国家储油罐防雷系统","authors":"Bryan Denov, Ilham Hendratama, R. Zoro","doi":"10.1109/ICHVEPS47643.2019.9011116","DOIUrl":null,"url":null,"abstract":"Lightning phenomenon in Indonesia draws attention of a lot of lightning protection engineer because of its high annual lightning flash density which has the different lightning characteristic compare to sub-tropical lightning. Most of the oil and gas companies adopt the sub-tropical lightning characteristic for the protection of their facilities such as IEC, NFPA, etc. and these standards are applied by companies, consultants and engineers to many structures and facilities in Indonesia. Due to these tropical weather condition, tanks and refinery are not inherently self-protected against lightning direct strikes, they need additional protection to prevent direct strike to tank's metal skin, breather valve at the top of tanks and automatic tank gauging (ATG). Statistically, almost every year the tank is hit by lightning in Indonesia and burn out. An innovation technology calls extended mast terminal (EMT) and free-standing mast (FSM) are used to protect tanks and refinery from lightning direct strikes. A tank was directly hit by lightning and burn out in PT Pertamina EP Asset 5 Sangasanga area at East Kalimantan since in-proper lightning protection system was applied. It has been observed and analyzed that not only need the additional protection but proper additional lightning protection for tanks and refinery is needed.","PeriodicalId":6677,"journal":{"name":"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)","volume":"18 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Lightning Protection System of Oil Storage Tank In Tropical Country\",\"authors\":\"Bryan Denov, Ilham Hendratama, R. Zoro\",\"doi\":\"10.1109/ICHVEPS47643.2019.9011116\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Lightning phenomenon in Indonesia draws attention of a lot of lightning protection engineer because of its high annual lightning flash density which has the different lightning characteristic compare to sub-tropical lightning. Most of the oil and gas companies adopt the sub-tropical lightning characteristic for the protection of their facilities such as IEC, NFPA, etc. and these standards are applied by companies, consultants and engineers to many structures and facilities in Indonesia. Due to these tropical weather condition, tanks and refinery are not inherently self-protected against lightning direct strikes, they need additional protection to prevent direct strike to tank's metal skin, breather valve at the top of tanks and automatic tank gauging (ATG). Statistically, almost every year the tank is hit by lightning in Indonesia and burn out. An innovation technology calls extended mast terminal (EMT) and free-standing mast (FSM) are used to protect tanks and refinery from lightning direct strikes. A tank was directly hit by lightning and burn out in PT Pertamina EP Asset 5 Sangasanga area at East Kalimantan since in-proper lightning protection system was applied. It has been observed and analyzed that not only need the additional protection but proper additional lightning protection for tanks and refinery is needed.\",\"PeriodicalId\":6677,\"journal\":{\"name\":\"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)\",\"volume\":\"18 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVEPS47643.2019.9011116\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 2nd International Conference on High Voltage Engineering and Power Systems (ICHVEPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVEPS47643.2019.9011116","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

印度尼西亚的雷电现象引起了许多防雷工程师的关注,因为它的年闪电密度很高,与亚热带闪电相比具有不同的闪电特征。大多数石油和天然气公司采用亚热带雷电特征来保护其设施,如IEC, NFPA等,这些标准被公司,顾问和工程师应用于印度尼西亚的许多结构和设施。由于这些热带天气条件,储罐和炼油厂本身并不能抵御雷击,它们需要额外的保护,以防止直接击中储罐的金属外壳、储罐顶部的呼吸阀和自动储罐计量(ATG)。据统计,几乎每年都有坦克在印度尼西亚被闪电击中并烧毁。一项名为扩展桅杆终端(EMT)和独立式桅杆终端(FSM)的创新技术被用于保护储罐和炼油厂免受雷击。在东加里曼丹的PT Pertamina EP资产5 Sangasanga地区,由于使用了不适当的防雷系统,一辆坦克被闪电直接击中并烧毁。观察和分析了储罐和炼油厂不仅需要额外的防雷保护,而且需要适当的额外防雷保护。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Lightning Protection System of Oil Storage Tank In Tropical Country
Lightning phenomenon in Indonesia draws attention of a lot of lightning protection engineer because of its high annual lightning flash density which has the different lightning characteristic compare to sub-tropical lightning. Most of the oil and gas companies adopt the sub-tropical lightning characteristic for the protection of their facilities such as IEC, NFPA, etc. and these standards are applied by companies, consultants and engineers to many structures and facilities in Indonesia. Due to these tropical weather condition, tanks and refinery are not inherently self-protected against lightning direct strikes, they need additional protection to prevent direct strike to tank's metal skin, breather valve at the top of tanks and automatic tank gauging (ATG). Statistically, almost every year the tank is hit by lightning in Indonesia and burn out. An innovation technology calls extended mast terminal (EMT) and free-standing mast (FSM) are used to protect tanks and refinery from lightning direct strikes. A tank was directly hit by lightning and burn out in PT Pertamina EP Asset 5 Sangasanga area at East Kalimantan since in-proper lightning protection system was applied. It has been observed and analyzed that not only need the additional protection but proper additional lightning protection for tanks and refinery is needed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Literature Survey of Optimization Technique of Unit Commitment Implementation in Microgrid Electricity System With Renewable Energy Sources Observation of Partial Discharge Waveform of Electrical Treeing in Epoxy Resin with Filler Implementation of Over Current Relays with Non-Cascade Scheme on Medium Voltage Switchgear as Busbar Protection Study Case in PT PLN (Persero) UIT JBB Optimal Capacitor Placement For IEEE 118 Bus System By Using Genetic Algorithm An active clamped two switch flyback Zeta converter with reduced switch voltage stress
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1