{"title":"多探测器共聚焦荧光显微镜成像技术的改进","authors":"R Gauderon, C J R Sheppard","doi":"10.1002/1361-6374(199809)6:3<126::AID-BIO2>3.0.CO;2-L","DOIUrl":null,"url":null,"abstract":"<p>Imaging performance in a confocal fluorescent microscope can be improved by using multiple detectors. The use of a large detector radius in a confocal fluorescent microscope, while giving a strong signal for lower spatial frequencies, results in negative components at some higher frequencies. Using this fact, effects of a simple detector array consisting of the difference signal between small and large detectors are considered. The effects on the transverse and axial variation of the three-dimensional optical transfer functions (OTFs) of the confocal fluorescent microscope are considered. The results show that the resulting OTFs are boosted, resulting in a better resolution.</p>","PeriodicalId":100176,"journal":{"name":"Bioimaging","volume":"6 3","pages":"126-129"},"PeriodicalIF":0.0000,"publicationDate":"2001-05-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/1361-6374(199809)6:3<126::AID-BIO2>3.0.CO;2-L","citationCount":"10","resultStr":"{\"title\":\"Improvement in imaging in confocal fluorescent microscopes using multiple detectors\",\"authors\":\"R Gauderon, C J R Sheppard\",\"doi\":\"10.1002/1361-6374(199809)6:3<126::AID-BIO2>3.0.CO;2-L\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Imaging performance in a confocal fluorescent microscope can be improved by using multiple detectors. The use of a large detector radius in a confocal fluorescent microscope, while giving a strong signal for lower spatial frequencies, results in negative components at some higher frequencies. Using this fact, effects of a simple detector array consisting of the difference signal between small and large detectors are considered. The effects on the transverse and axial variation of the three-dimensional optical transfer functions (OTFs) of the confocal fluorescent microscope are considered. The results show that the resulting OTFs are boosted, resulting in a better resolution.</p>\",\"PeriodicalId\":100176,\"journal\":{\"name\":\"Bioimaging\",\"volume\":\"6 3\",\"pages\":\"126-129\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-05-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/1361-6374(199809)6:3<126::AID-BIO2>3.0.CO;2-L\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioimaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/1361-6374%28199809%296%3A3%3C126%3A%3AAID-BIO2%3E3.0.CO%3B2-L\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioimaging","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/1361-6374%28199809%296%3A3%3C126%3A%3AAID-BIO2%3E3.0.CO%3B2-L","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Improvement in imaging in confocal fluorescent microscopes using multiple detectors
Imaging performance in a confocal fluorescent microscope can be improved by using multiple detectors. The use of a large detector radius in a confocal fluorescent microscope, while giving a strong signal for lower spatial frequencies, results in negative components at some higher frequencies. Using this fact, effects of a simple detector array consisting of the difference signal between small and large detectors are considered. The effects on the transverse and axial variation of the three-dimensional optical transfer functions (OTFs) of the confocal fluorescent microscope are considered. The results show that the resulting OTFs are boosted, resulting in a better resolution.