模糊方法在泵站节能经济修复中的应用

V. Radulescu
{"title":"模糊方法在泵站节能经济修复中的应用","authors":"V. Radulescu","doi":"10.1115/fedsm2021-65616","DOIUrl":null,"url":null,"abstract":"\n Many pumping stations require an urgent rehabilitation from hydraulic, energetic, and economic point of view, being older than 30 years. Some urban stations for the water supply are nowadays under-dimensioned compared with the necessary consumption. Such an example is the pumping station of the Buzau City, realized in 1986. Its population has grown in the last decades by about 30% due to industrial development and its water pumping station from the treatment plant is currently totally insufficient. The hydraulic losses through the control discharge valve have become too high. This pumping station ensures the water supply for the south and east part of the city. Firstly, some characteristics of the pumping station equipped with pumps 12NDS- Normal-Double spiral casing-Single-layer of 160kW and 18NDS of 400kW and 500 kW, all from domestic production, are presented. Modernization of the pumping station has started few years ago and being realized in steps, so as not interrupt the city’s water supply. To establish the optimal operating point some algorithms are presented, developed based on the experimental data and using functions with one or two independent variables. Firstly, the interpolation function is determined, followed by its numerical calculation. To establish the characteristics’ equations H = f(Q), P = f(Q), and η = f(Q) starting from experimental results obtained by direct measurements, a polynomial approximation was chosen by the method of the least squares, using the polynomials Lagrange and Bezier. For optimization, the fuzzy technique is adopted regarding the flow fusing, intervals between start and stop following some policies concerning the aggregates’ starting. For a year, the energy saved between these intervals was calculated. Finally, the obtained yields of about 90% proved that the pumps modernization adopting new functioning techniques is more advantageous in some situations than the purchase of new equipment.","PeriodicalId":23636,"journal":{"name":"Volume 2: Fluid Applications and Systems; Fluid Measurement and Instrumentation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Fuzzy Method Applied at Energetic and Economic Rehabilitation of Pumping Station\",\"authors\":\"V. Radulescu\",\"doi\":\"10.1115/fedsm2021-65616\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Many pumping stations require an urgent rehabilitation from hydraulic, energetic, and economic point of view, being older than 30 years. Some urban stations for the water supply are nowadays under-dimensioned compared with the necessary consumption. Such an example is the pumping station of the Buzau City, realized in 1986. Its population has grown in the last decades by about 30% due to industrial development and its water pumping station from the treatment plant is currently totally insufficient. The hydraulic losses through the control discharge valve have become too high. This pumping station ensures the water supply for the south and east part of the city. Firstly, some characteristics of the pumping station equipped with pumps 12NDS- Normal-Double spiral casing-Single-layer of 160kW and 18NDS of 400kW and 500 kW, all from domestic production, are presented. Modernization of the pumping station has started few years ago and being realized in steps, so as not interrupt the city’s water supply. To establish the optimal operating point some algorithms are presented, developed based on the experimental data and using functions with one or two independent variables. Firstly, the interpolation function is determined, followed by its numerical calculation. To establish the characteristics’ equations H = f(Q), P = f(Q), and η = f(Q) starting from experimental results obtained by direct measurements, a polynomial approximation was chosen by the method of the least squares, using the polynomials Lagrange and Bezier. For optimization, the fuzzy technique is adopted regarding the flow fusing, intervals between start and stop following some policies concerning the aggregates’ starting. For a year, the energy saved between these intervals was calculated. Finally, the obtained yields of about 90% proved that the pumps modernization adopting new functioning techniques is more advantageous in some situations than the purchase of new equipment.\",\"PeriodicalId\":23636,\"journal\":{\"name\":\"Volume 2: Fluid Applications and Systems; Fluid Measurement and Instrumentation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 2: Fluid Applications and Systems; Fluid Measurement and Instrumentation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/fedsm2021-65616\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 2: Fluid Applications and Systems; Fluid Measurement and Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/fedsm2021-65616","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

许多已使用超过30年的泵站,从水力、能源和经济的角度来看,迫切需要修复。目前,一些城市供水站的尺寸与必要的消耗量相比不足。1986年建成的布祖市泵站就是这样一个例子。在过去的几十年里,由于工业的发展,它的人口增长了大约30%,而它的污水处理厂的抽水站目前完全不足。通过控制排放阀的液压损失过高。这个泵站保证了城市南部和东部的供水。首先介绍了国产12NDS-普通-双螺旋套管-单层泵(160kW)和18NDS (400kW和500kw)泵站的一些特点。泵站的现代化改造在几年前就开始了,并且正在逐步实现,这样就不会中断城市的供水。为了确定最优工作点,提出了一些基于实验数据和使用一个或两个自变量函数的算法。首先确定插值函数,然后进行数值计算。为了从直接测量得到的实验结果出发,建立特征方程H = f(Q)、P = f(Q)和η = f(Q),采用拉格朗日多项式和贝塞尔多项式,采用最小二乘法选择多项式近似。为了优化,在流量融合、启动和停止间隔方面采用模糊技术,并遵循一些关于聚合体启动的策略。在一年的时间里,计算了这些间隔之间节省的能源。最后,获得的产量约为90%,证明在某些情况下,采用新的功能技术对泵进行现代化改造比购买新设备更有利。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fuzzy Method Applied at Energetic and Economic Rehabilitation of Pumping Station
Many pumping stations require an urgent rehabilitation from hydraulic, energetic, and economic point of view, being older than 30 years. Some urban stations for the water supply are nowadays under-dimensioned compared with the necessary consumption. Such an example is the pumping station of the Buzau City, realized in 1986. Its population has grown in the last decades by about 30% due to industrial development and its water pumping station from the treatment plant is currently totally insufficient. The hydraulic losses through the control discharge valve have become too high. This pumping station ensures the water supply for the south and east part of the city. Firstly, some characteristics of the pumping station equipped with pumps 12NDS- Normal-Double spiral casing-Single-layer of 160kW and 18NDS of 400kW and 500 kW, all from domestic production, are presented. Modernization of the pumping station has started few years ago and being realized in steps, so as not interrupt the city’s water supply. To establish the optimal operating point some algorithms are presented, developed based on the experimental data and using functions with one or two independent variables. Firstly, the interpolation function is determined, followed by its numerical calculation. To establish the characteristics’ equations H = f(Q), P = f(Q), and η = f(Q) starting from experimental results obtained by direct measurements, a polynomial approximation was chosen by the method of the least squares, using the polynomials Lagrange and Bezier. For optimization, the fuzzy technique is adopted regarding the flow fusing, intervals between start and stop following some policies concerning the aggregates’ starting. For a year, the energy saved between these intervals was calculated. Finally, the obtained yields of about 90% proved that the pumps modernization adopting new functioning techniques is more advantageous in some situations than the purchase of new equipment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fluid Dynamics and Contact Stress on Hard Sealing Surface Analysis of LNG Cryogenic Ball Valve 0D Modeling of Fuel Tank for Vapor Generation Impact of Urban Microclimate on Air Conditioning Energy Consumption Using Different Convective Heat Transfer Coefficient Correlations Available in Building Energy Simulation Tools Study on Overall Design of a Vertical Take-Off and Landing Unmanned Aerial Vehicle Powered by Electric Ducted Fans Influence of the Topological Structures of the Nose of High-Speed Maglev Train on Aerodynamic Performances
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1