北卡罗来纳州Currituck县Corolla Light #1污水处理设施污水扩散区地下水监测井的参数相关性

Q3 Social Sciences Environmental Practice Pub Date : 2017-08-11 DOI:10.1080/14660466.2017.1357390
Lorna C. Withrow
{"title":"北卡罗来纳州Currituck县Corolla Light #1污水处理设施污水扩散区地下水监测井的参数相关性","authors":"Lorna C. Withrow","doi":"10.1080/14660466.2017.1357390","DOIUrl":null,"url":null,"abstract":"ABSTRACT More than half of North Carolina’s population utilizes groundwater as a drinking water source. Efforts to protect water sources include groundwater monitoring around some of the larger wastewater systems. Samples collected from system monitoring wells are analyzed for selected contaminants, typically outlined in wastewater systems’ operation permits. Detection of targeted parameters can result in early intervention of contamination identified through parameter correlation. This investigation focused on wells located around the Corolla Light #1 WWTF in the Corolla, NC. The WWTF has seven system monitoring wells for which sample analyses results were assessed for discernable correlations between parameters. The On-Site Water Protection (OSWP) system is monitored by wells MW-4, MW-5, and MW-6. The Division of Water Resources (DWR) system is monitored by wells MW-1, MW-2, MW-3, and MW-7. The OSWP system utilizes subsurface dispersal and the DWR system utilizes surface dispersal. Monitoring conducted around the areas is reported to OSWP and DWR. Results for samples collected November 2006–2016 were compiled and results for pH, TDS, Cl-, and NO3- examined. Evaluation by regression analyses appeared to indicate no correlation between concentrations of NO3- and the other three parameters. There did appear to be a significant relationship between TDS and Cl- in five of seven wells sampled. Only two wells (MW-1 and MW-7) appeared to have a relationship between pH and both TDS and Cl-.","PeriodicalId":45250,"journal":{"name":"Environmental Practice","volume":"5 1","pages":"182 - 195"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Parameter correlation in wastewater dispersal area groundwater monitoring wells serving Corolla Light #1 Wastewater Treatment Facility in Currituck County, North Carolina\",\"authors\":\"Lorna C. Withrow\",\"doi\":\"10.1080/14660466.2017.1357390\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT More than half of North Carolina’s population utilizes groundwater as a drinking water source. Efforts to protect water sources include groundwater monitoring around some of the larger wastewater systems. Samples collected from system monitoring wells are analyzed for selected contaminants, typically outlined in wastewater systems’ operation permits. Detection of targeted parameters can result in early intervention of contamination identified through parameter correlation. This investigation focused on wells located around the Corolla Light #1 WWTF in the Corolla, NC. The WWTF has seven system monitoring wells for which sample analyses results were assessed for discernable correlations between parameters. The On-Site Water Protection (OSWP) system is monitored by wells MW-4, MW-5, and MW-6. The Division of Water Resources (DWR) system is monitored by wells MW-1, MW-2, MW-3, and MW-7. The OSWP system utilizes subsurface dispersal and the DWR system utilizes surface dispersal. Monitoring conducted around the areas is reported to OSWP and DWR. Results for samples collected November 2006–2016 were compiled and results for pH, TDS, Cl-, and NO3- examined. Evaluation by regression analyses appeared to indicate no correlation between concentrations of NO3- and the other three parameters. There did appear to be a significant relationship between TDS and Cl- in five of seven wells sampled. Only two wells (MW-1 and MW-7) appeared to have a relationship between pH and both TDS and Cl-.\",\"PeriodicalId\":45250,\"journal\":{\"name\":\"Environmental Practice\",\"volume\":\"5 1\",\"pages\":\"182 - 195\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-08-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environmental Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/14660466.2017.1357390\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Social Sciences\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/14660466.2017.1357390","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Social Sciences","Score":null,"Total":0}
引用次数: 1

摘要

北卡罗来纳州一半以上的人口使用地下水作为饮用水源。保护水源的努力包括在一些较大的污水处理系统周围监测地下水。从系统监测井收集的样本进行分析,以确定选定的污染物,通常在废水系统的运行许可证中列出。通过检测目标参数,可以对通过参数相关性识别的污染进行早期干预。本次调查的重点是位于北卡罗来纳州卡罗拉的卡罗拉光#1 WWTF周围的井。WWTF有七个系统监测井,对样本分析结果进行了评估,以确定参数之间的可识别相关性。现场水保护(OSWP)系统由MW-4、MW-5和MW-6井监控。水资源分配(DWR)系统由MW-1、MW-2、MW-3和MW-7井监测。OSWP系统采用地下分散,DWR系统采用地面分散。在这些地区周围进行的监测工作向OSWP和DWR报告。收集了2006-2016年11月采集的样品的结果,并检查了pH、TDS、Cl-和NO3-的结果。回归分析表明NO3-浓度与其他三个参数之间没有相关性。在抽样的7口井中,有5口井的TDS和Cl-之间似乎存在显著的关系。只有两个井(MW-1和MW-7)的pH值与TDS和Cl-都有关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Parameter correlation in wastewater dispersal area groundwater monitoring wells serving Corolla Light #1 Wastewater Treatment Facility in Currituck County, North Carolina
ABSTRACT More than half of North Carolina’s population utilizes groundwater as a drinking water source. Efforts to protect water sources include groundwater monitoring around some of the larger wastewater systems. Samples collected from system monitoring wells are analyzed for selected contaminants, typically outlined in wastewater systems’ operation permits. Detection of targeted parameters can result in early intervention of contamination identified through parameter correlation. This investigation focused on wells located around the Corolla Light #1 WWTF in the Corolla, NC. The WWTF has seven system monitoring wells for which sample analyses results were assessed for discernable correlations between parameters. The On-Site Water Protection (OSWP) system is monitored by wells MW-4, MW-5, and MW-6. The Division of Water Resources (DWR) system is monitored by wells MW-1, MW-2, MW-3, and MW-7. The OSWP system utilizes subsurface dispersal and the DWR system utilizes surface dispersal. Monitoring conducted around the areas is reported to OSWP and DWR. Results for samples collected November 2006–2016 were compiled and results for pH, TDS, Cl-, and NO3- examined. Evaluation by regression analyses appeared to indicate no correlation between concentrations of NO3- and the other three parameters. There did appear to be a significant relationship between TDS and Cl- in five of seven wells sampled. Only two wells (MW-1 and MW-7) appeared to have a relationship between pH and both TDS and Cl-.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Environmental Practice
Environmental Practice ENVIRONMENTAL SCIENCES-
CiteScore
0.90
自引率
0.00%
发文量
0
期刊介绍: Environmental Practice provides a multidisciplinary forum for authoritative discussion and analysis of issues of wide interest to the international community of environmental professionals, with the intent of developing innovative solutions to environmental problems for public policy implementation, professional practice, or both. Peer-reviewed original research papers, environmental reviews, and commentaries, along with news articles, book reviews, and points of view, link findings in science and technology with issues of public policy, health, environmental quality, law, political economy, management, and the appropriate standards for expertise. Published for the National Association of Environmental Professionals
期刊最新文献
Anthropological approaches for cultural resource conservation design and planning Cultural resources and landscape conservation design and planning Moving beyond the ecosystem in ecosystem health report cards Food Loss and Food Waste, Causes and Solutions Last issue of Environmental Practice
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1