边界条件对波希式注射速率计的影响

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2021-03-01 DOI:10.3846/TRANSPORT.2021.14351
Sándor Vass, M. Zöldy
{"title":"边界条件对波希式注射速率计的影响","authors":"Sándor Vass, M. Zöldy","doi":"10.3846/TRANSPORT.2021.14351","DOIUrl":null,"url":null,"abstract":"Spread and evolution of Common Rail (CR) injection systems enable to influence injection events more efficiently than ever, while injection mass flow rate during an injection event crucially affects the combustion process. A measurement device based on the work of Bosch was set up, and measurements were made with different boundary conditions to explore the capabilities of the measurement system and to validate a detailed model of a CR injector. The main finding of this research work is, that orifice size had no noticeable effect on the measured injection rate traces, while it was stated in the original work that a small orifice is needed to terminate the measuring tube to maintain stable measurement conditions. Moreover, the backpressure level in the measuring system has a significant effect on the measured injection traces. If pressure in the measuring tube is low, gradient at the injection rate rise is lower, while if the pressure is comparable with that of a combustion chamber maximal compression pressure, measurement of higher doses is unaccomplishable due to the long pressure decrease time in the measuring tube after the end of the injection. Based on the results of the investigation, it can be stated that the Bosch-type injection rate measurement method does not give back the exact injection rate shape, a supplementing method would be necessary to calculate real nozzle flow rate.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2021-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"EFFECTS OF BOUNDARY CONDITIONS ON A BOSCH-TYPE INJECTION RATE METER\",\"authors\":\"Sándor Vass, M. Zöldy\",\"doi\":\"10.3846/TRANSPORT.2021.14351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Spread and evolution of Common Rail (CR) injection systems enable to influence injection events more efficiently than ever, while injection mass flow rate during an injection event crucially affects the combustion process. A measurement device based on the work of Bosch was set up, and measurements were made with different boundary conditions to explore the capabilities of the measurement system and to validate a detailed model of a CR injector. The main finding of this research work is, that orifice size had no noticeable effect on the measured injection rate traces, while it was stated in the original work that a small orifice is needed to terminate the measuring tube to maintain stable measurement conditions. Moreover, the backpressure level in the measuring system has a significant effect on the measured injection traces. If pressure in the measuring tube is low, gradient at the injection rate rise is lower, while if the pressure is comparable with that of a combustion chamber maximal compression pressure, measurement of higher doses is unaccomplishable due to the long pressure decrease time in the measuring tube after the end of the injection. Based on the results of the investigation, it can be stated that the Bosch-type injection rate measurement method does not give back the exact injection rate shape, a supplementing method would be necessary to calculate real nozzle flow rate.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2021-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3846/TRANSPORT.2021.14351\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3846/TRANSPORT.2021.14351","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1

摘要

共轨(CR)喷射系统的普及和发展使其能够比以往更有效地影响喷射事件,而喷射事件中的喷射质量流量对燃烧过程至关重要。搭建了基于Bosch工作成果的测量装置,并在不同的边界条件下进行了测量,以探索测量系统的能力,并验证了CR喷油器的详细模型。本研究工作的主要发现是,孔口尺寸对测量的注射速率轨迹没有明显的影响,而在原工作中指出,需要一个小的孔口来终止测量管以保持稳定的测量条件。此外,测量系统中的背压水平对测量的喷射轨迹有显著影响。如果测量管内压力较低,则喷射速度上升时的梯度较低,而如果压力与燃烧室最大压缩压力相当,则由于喷射结束后测量管内压力下降时间较长,因此无法测量更高剂量。从研究结果可以看出,波希式喷油速率测量方法并不能给出准确的喷油速率形状,需要一种补充方法来计算真实的喷嘴流量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
EFFECTS OF BOUNDARY CONDITIONS ON A BOSCH-TYPE INJECTION RATE METER
Spread and evolution of Common Rail (CR) injection systems enable to influence injection events more efficiently than ever, while injection mass flow rate during an injection event crucially affects the combustion process. A measurement device based on the work of Bosch was set up, and measurements were made with different boundary conditions to explore the capabilities of the measurement system and to validate a detailed model of a CR injector. The main finding of this research work is, that orifice size had no noticeable effect on the measured injection rate traces, while it was stated in the original work that a small orifice is needed to terminate the measuring tube to maintain stable measurement conditions. Moreover, the backpressure level in the measuring system has a significant effect on the measured injection traces. If pressure in the measuring tube is low, gradient at the injection rate rise is lower, while if the pressure is comparable with that of a combustion chamber maximal compression pressure, measurement of higher doses is unaccomplishable due to the long pressure decrease time in the measuring tube after the end of the injection. Based on the results of the investigation, it can be stated that the Bosch-type injection rate measurement method does not give back the exact injection rate shape, a supplementing method would be necessary to calculate real nozzle flow rate.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Mentorship in academic musculoskeletal radiology: perspectives from a junior faculty member. Underlying synovial sarcoma undiagnosed for more than 20 years in a patient with regional pain: a case report. Sacrococcygeal chordoma with spontaneous regression due to a large hemorrhagic component. Associations of cumulative voriconazole dose, treatment duration, and alkaline phosphatase with voriconazole-induced periostitis. Can the presence of SLAP-5 lesions be predicted by using the critical shoulder angle in traumatic anterior shoulder instability?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1