图形软件在分析患者下肢热像图中的新可能性-技术说明

IF 0.7 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Polish Journal of Medical Physics and Engineering Pub Date : 2021-06-01 DOI:10.2478/pjmpe-2021-0021
Monika Wideł, S. Grzegorczyn
{"title":"图形软件在分析患者下肢热像图中的新可能性-技术说明","authors":"Monika Wideł, S. Grzegorczyn","doi":"10.2478/pjmpe-2021-0021","DOIUrl":null,"url":null,"abstract":"Abstract The analysis involved thermograms of the lower limbs of a patient suffering from symptomatic L-S segment discopathy with spinal root compression syndrome (symptomatic lumbar discopathy) qualified for surgical treatment. The thermograms were obtained using the Flir Ebx 50 camera. They were developed with the use of the software included with the Flir Ebx 50 camera, as well as the Origin Pro 2020 data analysis and graphing software. ROIs (Regions of Interest) were specified and analyzed in terms of temperature (average, maximum or minimum) temperature distributions, isotherms, and specified surface areas limited by selected isotherms. According to the analysis of the thermograms, the images obtained with Origin Pro 2020 enable a more advanced presentation of the temperature distribution, by taking into account the isotherms with selected temperatures and by calculating the area limited by a given isotherm (or between two isotherms) they allow to introduce an additional surface parameter related to specific isotherms. It provides additional information (parameter) in comparison with analogous ROIs on healthy and pathologic limbs in the same patient.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"15 1","pages":"175 - 180"},"PeriodicalIF":0.7000,"publicationDate":"2021-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"New possibilities of graphics software in the analysis of thermograms of patient’s lower limbs – a technical note\",\"authors\":\"Monika Wideł, S. Grzegorczyn\",\"doi\":\"10.2478/pjmpe-2021-0021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The analysis involved thermograms of the lower limbs of a patient suffering from symptomatic L-S segment discopathy with spinal root compression syndrome (symptomatic lumbar discopathy) qualified for surgical treatment. The thermograms were obtained using the Flir Ebx 50 camera. They were developed with the use of the software included with the Flir Ebx 50 camera, as well as the Origin Pro 2020 data analysis and graphing software. ROIs (Regions of Interest) were specified and analyzed in terms of temperature (average, maximum or minimum) temperature distributions, isotherms, and specified surface areas limited by selected isotherms. According to the analysis of the thermograms, the images obtained with Origin Pro 2020 enable a more advanced presentation of the temperature distribution, by taking into account the isotherms with selected temperatures and by calculating the area limited by a given isotherm (or between two isotherms) they allow to introduce an additional surface parameter related to specific isotherms. It provides additional information (parameter) in comparison with analogous ROIs on healthy and pathologic limbs in the same patient.\",\"PeriodicalId\":53955,\"journal\":{\"name\":\"Polish Journal of Medical Physics and Engineering\",\"volume\":\"15 1\",\"pages\":\"175 - 180\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2021-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polish Journal of Medical Physics and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/pjmpe-2021-0021\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Medical Physics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/pjmpe-2021-0021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

摘要:本文分析了一例症状性L-S节段脱位合并脊髓根压迫综合征(症状性腰椎脱位)患者的下肢热像图,该患者适合手术治疗。热像图使用Flir Ebx 50相机获得。它们是使用Flir Ebx 50相机附带的软件以及Origin Pro 2020数据分析和绘图软件开发的。根据温度(平均、最高或最低)温度分布、等温线和受选定等温线限制的指定表面积来指定和分析roi(兴趣区域)。根据对热图的分析,使用Origin Pro 2020获得的图像可以更高级地呈现温度分布,通过考虑选定温度下的等温线,并通过计算给定等温线(或两个等温线之间)限制的面积,它们可以引入与特定等温线相关的额外表面参数。它提供了额外的信息(参数),比较类似的roi在同一患者的健康和病理肢体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
New possibilities of graphics software in the analysis of thermograms of patient’s lower limbs – a technical note
Abstract The analysis involved thermograms of the lower limbs of a patient suffering from symptomatic L-S segment discopathy with spinal root compression syndrome (symptomatic lumbar discopathy) qualified for surgical treatment. The thermograms were obtained using the Flir Ebx 50 camera. They were developed with the use of the software included with the Flir Ebx 50 camera, as well as the Origin Pro 2020 data analysis and graphing software. ROIs (Regions of Interest) were specified and analyzed in terms of temperature (average, maximum or minimum) temperature distributions, isotherms, and specified surface areas limited by selected isotherms. According to the analysis of the thermograms, the images obtained with Origin Pro 2020 enable a more advanced presentation of the temperature distribution, by taking into account the isotherms with selected temperatures and by calculating the area limited by a given isotherm (or between two isotherms) they allow to introduce an additional surface parameter related to specific isotherms. It provides additional information (parameter) in comparison with analogous ROIs on healthy and pathologic limbs in the same patient.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Polish Journal of Medical Physics and Engineering
Polish Journal of Medical Physics and Engineering RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.30
自引率
0.00%
发文量
19
期刊介绍: Polish Journal of Medical Physics and Engineering (PJMPE) (Online ISSN: 1898-0309; Print ISSN: 1425-4689) is an official publication of the Polish Society of Medical Physics. It is a peer-reviewed, open access scientific journal with no publication fees. The issues are published quarterly online. The Journal publishes original contribution in medical physics and biomedical engineering.
期刊最新文献
Parametrization of subsegmental infarcts using high spatial resolution 2DSTE and synthetic ultrasonic data Automated differential diagnostics of respiratory diseases using an electronic stethoscope Evaluating the impact of anatomical changes on dose distributions in head and neck cancer Comparing eDQE and eNEQ metrics – is there an alternative approach to assessing image quality in digital mammography? Vascular stiffness in cold pressor test hyper-reactors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1