{"title":"图形软件在分析患者下肢热像图中的新可能性-技术说明","authors":"Monika Wideł, S. Grzegorczyn","doi":"10.2478/pjmpe-2021-0021","DOIUrl":null,"url":null,"abstract":"Abstract The analysis involved thermograms of the lower limbs of a patient suffering from symptomatic L-S segment discopathy with spinal root compression syndrome (symptomatic lumbar discopathy) qualified for surgical treatment. The thermograms were obtained using the Flir Ebx 50 camera. They were developed with the use of the software included with the Flir Ebx 50 camera, as well as the Origin Pro 2020 data analysis and graphing software. ROIs (Regions of Interest) were specified and analyzed in terms of temperature (average, maximum or minimum) temperature distributions, isotherms, and specified surface areas limited by selected isotherms. According to the analysis of the thermograms, the images obtained with Origin Pro 2020 enable a more advanced presentation of the temperature distribution, by taking into account the isotherms with selected temperatures and by calculating the area limited by a given isotherm (or between two isotherms) they allow to introduce an additional surface parameter related to specific isotherms. It provides additional information (parameter) in comparison with analogous ROIs on healthy and pathologic limbs in the same patient.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"15 1","pages":"175 - 180"},"PeriodicalIF":0.7000,"publicationDate":"2021-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"New possibilities of graphics software in the analysis of thermograms of patient’s lower limbs – a technical note\",\"authors\":\"Monika Wideł, S. Grzegorczyn\",\"doi\":\"10.2478/pjmpe-2021-0021\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The analysis involved thermograms of the lower limbs of a patient suffering from symptomatic L-S segment discopathy with spinal root compression syndrome (symptomatic lumbar discopathy) qualified for surgical treatment. The thermograms were obtained using the Flir Ebx 50 camera. They were developed with the use of the software included with the Flir Ebx 50 camera, as well as the Origin Pro 2020 data analysis and graphing software. ROIs (Regions of Interest) were specified and analyzed in terms of temperature (average, maximum or minimum) temperature distributions, isotherms, and specified surface areas limited by selected isotherms. According to the analysis of the thermograms, the images obtained with Origin Pro 2020 enable a more advanced presentation of the temperature distribution, by taking into account the isotherms with selected temperatures and by calculating the area limited by a given isotherm (or between two isotherms) they allow to introduce an additional surface parameter related to specific isotherms. It provides additional information (parameter) in comparison with analogous ROIs on healthy and pathologic limbs in the same patient.\",\"PeriodicalId\":53955,\"journal\":{\"name\":\"Polish Journal of Medical Physics and Engineering\",\"volume\":\"15 1\",\"pages\":\"175 - 180\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2021-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polish Journal of Medical Physics and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/pjmpe-2021-0021\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Medical Physics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/pjmpe-2021-0021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
摘要
摘要:本文分析了一例症状性L-S节段脱位合并脊髓根压迫综合征(症状性腰椎脱位)患者的下肢热像图,该患者适合手术治疗。热像图使用Flir Ebx 50相机获得。它们是使用Flir Ebx 50相机附带的软件以及Origin Pro 2020数据分析和绘图软件开发的。根据温度(平均、最高或最低)温度分布、等温线和受选定等温线限制的指定表面积来指定和分析roi(兴趣区域)。根据对热图的分析,使用Origin Pro 2020获得的图像可以更高级地呈现温度分布,通过考虑选定温度下的等温线,并通过计算给定等温线(或两个等温线之间)限制的面积,它们可以引入与特定等温线相关的额外表面参数。它提供了额外的信息(参数),比较类似的roi在同一患者的健康和病理肢体。
New possibilities of graphics software in the analysis of thermograms of patient’s lower limbs – a technical note
Abstract The analysis involved thermograms of the lower limbs of a patient suffering from symptomatic L-S segment discopathy with spinal root compression syndrome (symptomatic lumbar discopathy) qualified for surgical treatment. The thermograms were obtained using the Flir Ebx 50 camera. They were developed with the use of the software included with the Flir Ebx 50 camera, as well as the Origin Pro 2020 data analysis and graphing software. ROIs (Regions of Interest) were specified and analyzed in terms of temperature (average, maximum or minimum) temperature distributions, isotherms, and specified surface areas limited by selected isotherms. According to the analysis of the thermograms, the images obtained with Origin Pro 2020 enable a more advanced presentation of the temperature distribution, by taking into account the isotherms with selected temperatures and by calculating the area limited by a given isotherm (or between two isotherms) they allow to introduce an additional surface parameter related to specific isotherms. It provides additional information (parameter) in comparison with analogous ROIs on healthy and pathologic limbs in the same patient.
期刊介绍:
Polish Journal of Medical Physics and Engineering (PJMPE) (Online ISSN: 1898-0309; Print ISSN: 1425-4689) is an official publication of the Polish Society of Medical Physics. It is a peer-reviewed, open access scientific journal with no publication fees. The issues are published quarterly online. The Journal publishes original contribution in medical physics and biomedical engineering.