{"title":"大量皮下肺气肿和双侧张力性气胸经气道交换导管补充供氧后:1例报告","authors":"A. Hulst, Hans J. Avis, M. Hollmann, M. Stevens","doi":"10.1213/XAA.0000000000000414","DOIUrl":null,"url":null,"abstract":"A patient suffered massive subcutaneous emphysema and bilateral tension pneumothoraces after receiving supplemental oxygen through an airway exchange catheter (AEC). Complications of AEC placement include misplacement, direct injury to the larynx, bronchi or lung, barotrauma related to oxygen supplementation, and a loss of airway. We review these complications and discuss the specific risks of supplementing oxygen using an AEC. We suggest measures to limit pressure from the oxygen source and warn against advancing an AEC too far into the tracheobronchial tree.","PeriodicalId":6824,"journal":{"name":"A&A Case Reports ","volume":"12 1","pages":"26–28"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Massive Subcutaneous Emphysema and Bilateral Tension Pneumothoraces After Supplemental Oxygen Delivery via an Airway Exchange Catheter: A Case Report\",\"authors\":\"A. Hulst, Hans J. Avis, M. Hollmann, M. Stevens\",\"doi\":\"10.1213/XAA.0000000000000414\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A patient suffered massive subcutaneous emphysema and bilateral tension pneumothoraces after receiving supplemental oxygen through an airway exchange catheter (AEC). Complications of AEC placement include misplacement, direct injury to the larynx, bronchi or lung, barotrauma related to oxygen supplementation, and a loss of airway. We review these complications and discuss the specific risks of supplementing oxygen using an AEC. We suggest measures to limit pressure from the oxygen source and warn against advancing an AEC too far into the tracheobronchial tree.\",\"PeriodicalId\":6824,\"journal\":{\"name\":\"A&A Case Reports \",\"volume\":\"12 1\",\"pages\":\"26–28\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"A&A Case Reports \",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1213/XAA.0000000000000414\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"A&A Case Reports ","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1213/XAA.0000000000000414","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Massive Subcutaneous Emphysema and Bilateral Tension Pneumothoraces After Supplemental Oxygen Delivery via an Airway Exchange Catheter: A Case Report
A patient suffered massive subcutaneous emphysema and bilateral tension pneumothoraces after receiving supplemental oxygen through an airway exchange catheter (AEC). Complications of AEC placement include misplacement, direct injury to the larynx, bronchi or lung, barotrauma related to oxygen supplementation, and a loss of airway. We review these complications and discuss the specific risks of supplementing oxygen using an AEC. We suggest measures to limit pressure from the oxygen source and warn against advancing an AEC too far into the tracheobronchial tree.