{"title":"用电流系数估计直流导体电晕起始电压","authors":"Yuming Zhao, Minhua Ma, Jinwei Chu, Z. Guan","doi":"10.1109/CEIDP.2008.4772855","DOIUrl":null,"url":null,"abstract":"Corona onset voltage is an important parameter corresponding to corona characteristics. Existing onset voltage measurement methods can not distinguish the partial onset voltage and the onset voltage of transmission conductor. Based on analyzing corona onset and development process, a novel estimate method using current coefficient was presented to estimate DC onset voltage in this paper. The current coefficient method and other three methods were used to estimate corona onset voltage of smooth conductor and ACSR in four surface statuses.","PeriodicalId":6381,"journal":{"name":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"77 1","pages":"321-324"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Using Current Coefficient to Estimate DC Conductor Corona Onset Voltage\",\"authors\":\"Yuming Zhao, Minhua Ma, Jinwei Chu, Z. Guan\",\"doi\":\"10.1109/CEIDP.2008.4772855\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Corona onset voltage is an important parameter corresponding to corona characteristics. Existing onset voltage measurement methods can not distinguish the partial onset voltage and the onset voltage of transmission conductor. Based on analyzing corona onset and development process, a novel estimate method using current coefficient was presented to estimate DC onset voltage in this paper. The current coefficient method and other three methods were used to estimate corona onset voltage of smooth conductor and ACSR in four surface statuses.\",\"PeriodicalId\":6381,\"journal\":{\"name\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"77 1\",\"pages\":\"321-324\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2008.4772855\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2008.4772855","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Using Current Coefficient to Estimate DC Conductor Corona Onset Voltage
Corona onset voltage is an important parameter corresponding to corona characteristics. Existing onset voltage measurement methods can not distinguish the partial onset voltage and the onset voltage of transmission conductor. Based on analyzing corona onset and development process, a novel estimate method using current coefficient was presented to estimate DC onset voltage in this paper. The current coefficient method and other three methods were used to estimate corona onset voltage of smooth conductor and ACSR in four surface statuses.