A. Kudryashova, O. Borisova, N. Mikhailova, D. V. Lonshakov, A. V. Katlinsky
{"title":"血液血清中的IgG对epb的敏感性影响是实验性的。","authors":"A. Kudryashova, O. Borisova, N. Mikhailova, D. V. Lonshakov, A. V. Katlinsky","doi":"10.36233/0372-9311-2017-6-49-55","DOIUrl":null,"url":null,"abstract":"Aim. The study of the effect of the erythropoietin coating procedure on sensitivity using the same secondary detection methods to quantify anti-EPO IgG positive animal sera. Materials and methods. Sera from experimental animals - rabbits and guinea pigs - after rhEPO injection were used. The methods includes directly coated ELISA and two types of immunochemical immobilization: capturing biotinylated rhEPO on streptavidin coated microtiier plates and capturing rhEPO via a specific antibody Results. Immunochemical rhEPO immobilization results in a sensitivity from 2 to 10 of magnitude higher than direct coating of rhEPO. Conclusion. Our findings show that the method of rhEPO immobilization to microtiter plates is a critical determinant for the sensitivity of ELISA used for measuring anti-EPO antibodies. Assays in which rhEPO was captured via a specific mAb, or in which biotinylated rhEPO was captured via streptavidin, are preferred to detect serum antibodies to native structural state.","PeriodicalId":24020,"journal":{"name":"Zhurnal mikrobiologii, epidemiologii, i immunobiologii","volume":"16 5 1","pages":"49-55"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ВЛИЯНИЕ МЕТОДОВ ИММОБИЛИЗАЦИИ ЭРИТРОПОЭТИНА НА ЧУВСТВИТЕЛЬНОСТЬ ВЫЯВЛЕНИЯ СПЕЦИФИЧЕСКИХ IgG К EПB В СЫВОРОТКАХ КРОВИ ЭКСПЕРИМЕНТАЛЬНЫЙ ЖИВОТНЫХ\",\"authors\":\"A. Kudryashova, O. Borisova, N. Mikhailova, D. V. Lonshakov, A. V. Katlinsky\",\"doi\":\"10.36233/0372-9311-2017-6-49-55\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim. The study of the effect of the erythropoietin coating procedure on sensitivity using the same secondary detection methods to quantify anti-EPO IgG positive animal sera. Materials and methods. Sera from experimental animals - rabbits and guinea pigs - after rhEPO injection were used. The methods includes directly coated ELISA and two types of immunochemical immobilization: capturing biotinylated rhEPO on streptavidin coated microtiier plates and capturing rhEPO via a specific antibody Results. Immunochemical rhEPO immobilization results in a sensitivity from 2 to 10 of magnitude higher than direct coating of rhEPO. Conclusion. Our findings show that the method of rhEPO immobilization to microtiter plates is a critical determinant for the sensitivity of ELISA used for measuring anti-EPO antibodies. Assays in which rhEPO was captured via a specific mAb, or in which biotinylated rhEPO was captured via streptavidin, are preferred to detect serum antibodies to native structural state.\",\"PeriodicalId\":24020,\"journal\":{\"name\":\"Zhurnal mikrobiologii, epidemiologii, i immunobiologii\",\"volume\":\"16 5 1\",\"pages\":\"49-55\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-12-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zhurnal mikrobiologii, epidemiologii, i immunobiologii\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.36233/0372-9311-2017-6-49-55\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhurnal mikrobiologii, epidemiologii, i immunobiologii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36233/0372-9311-2017-6-49-55","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
ВЛИЯНИЕ МЕТОДОВ ИММОБИЛИЗАЦИИ ЭРИТРОПОЭТИНА НА ЧУВСТВИТЕЛЬНОСТЬ ВЫЯВЛЕНИЯ СПЕЦИФИЧЕСКИХ IgG К EПB В СЫВОРОТКАХ КРОВИ ЭКСПЕРИМЕНТАЛЬНЫЙ ЖИВОТНЫХ
Aim. The study of the effect of the erythropoietin coating procedure on sensitivity using the same secondary detection methods to quantify anti-EPO IgG positive animal sera. Materials and methods. Sera from experimental animals - rabbits and guinea pigs - after rhEPO injection were used. The methods includes directly coated ELISA and two types of immunochemical immobilization: capturing biotinylated rhEPO on streptavidin coated microtiier plates and capturing rhEPO via a specific antibody Results. Immunochemical rhEPO immobilization results in a sensitivity from 2 to 10 of magnitude higher than direct coating of rhEPO. Conclusion. Our findings show that the method of rhEPO immobilization to microtiter plates is a critical determinant for the sensitivity of ELISA used for measuring anti-EPO antibodies. Assays in which rhEPO was captured via a specific mAb, or in which biotinylated rhEPO was captured via streptavidin, are preferred to detect serum antibodies to native structural state.