水培温室加热的两层密实床潜在蓄能的有益利用

Sara Baddadi , Salwa Bouadila , AmenAllah Guizani
{"title":"水培温室加热的两层密实床潜在蓄能的有益利用","authors":"Sara Baddadi ,&nbsp;Salwa Bouadila ,&nbsp;AmenAllah Guizani","doi":"10.1016/j.egypro.2019.04.017","DOIUrl":null,"url":null,"abstract":"<div><p>The intensive energy requirements, the mismatch between the energy supply and demand and the nocturnal temperature drops are all crucial issues in the greenhouses solar heating. This paper seeks to evaluate the effect of a solar air heater with thermal latent storage on the greenhouse microclimate by pursuing the evolution of the internal climate before and after the heating. In this context, an experimental hydroponic greenhouse (HYDGR) and a solar air heater (SAHLSE) were realized in the Thermal Processes Laboratory in the Research and Technology Center of Energy of Borj Cédria in Tunisia. The solar heating with thermal energy storage enhanced the microclimate of the greenhouse and the temperature didn’t drop less than 32 and 15°C respectively the day and at night. The realized solar collector with thermal latent storage offered higher temperature even when the sun is unavailable and increased the internal temperature by more than 5°C. The studied solar system realized good improvement in the hydroponic greenhouse and appeared to be a beneficial alternative for ensuring optimal microclimate.</p></div>","PeriodicalId":11517,"journal":{"name":"Energy Procedia","volume":"162 ","pages":"Pages 156-163"},"PeriodicalIF":0.0000,"publicationDate":"2019-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.egypro.2019.04.017","citationCount":"12","resultStr":"{\"title\":\"Beneficial use of two packed beds of latent storage energy for the heating of a hydroponic greenhouse\",\"authors\":\"Sara Baddadi ,&nbsp;Salwa Bouadila ,&nbsp;AmenAllah Guizani\",\"doi\":\"10.1016/j.egypro.2019.04.017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The intensive energy requirements, the mismatch between the energy supply and demand and the nocturnal temperature drops are all crucial issues in the greenhouses solar heating. This paper seeks to evaluate the effect of a solar air heater with thermal latent storage on the greenhouse microclimate by pursuing the evolution of the internal climate before and after the heating. In this context, an experimental hydroponic greenhouse (HYDGR) and a solar air heater (SAHLSE) were realized in the Thermal Processes Laboratory in the Research and Technology Center of Energy of Borj Cédria in Tunisia. The solar heating with thermal energy storage enhanced the microclimate of the greenhouse and the temperature didn’t drop less than 32 and 15°C respectively the day and at night. The realized solar collector with thermal latent storage offered higher temperature even when the sun is unavailable and increased the internal temperature by more than 5°C. The studied solar system realized good improvement in the hydroponic greenhouse and appeared to be a beneficial alternative for ensuring optimal microclimate.</p></div>\",\"PeriodicalId\":11517,\"journal\":{\"name\":\"Energy Procedia\",\"volume\":\"162 \",\"pages\":\"Pages 156-163\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.egypro.2019.04.017\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy Procedia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1876610219313761\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Procedia","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1876610219313761","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

摘要

大量的能源需求、能源供需之间的不匹配以及夜间温度下降都是温室太阳能供暖的关键问题。本文通过研究潜热蓄热太阳能空气加热器加热前后室内气候的变化,探讨了潜热蓄热太阳能空气加热器对温室小气候的影响。在这种情况下,一个实验性水培温室(HYDGR)和一个太阳能空气加热器(SAHLSE)在突尼斯Borj cacria能源研究和技术中心的热过程实验室中实现。蓄热太阳能采暖增强了温室小气候,昼夜温度分别不低于32℃和15℃。所实现的具有潜热存储的太阳能集热器即使在没有太阳的情况下也能提供更高的温度,并将内部温度提高了5°C以上。所研究的太阳能系统在水培温室中实现了良好的改善,是保证最佳小气候的有益替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Beneficial use of two packed beds of latent storage energy for the heating of a hydroponic greenhouse

The intensive energy requirements, the mismatch between the energy supply and demand and the nocturnal temperature drops are all crucial issues in the greenhouses solar heating. This paper seeks to evaluate the effect of a solar air heater with thermal latent storage on the greenhouse microclimate by pursuing the evolution of the internal climate before and after the heating. In this context, an experimental hydroponic greenhouse (HYDGR) and a solar air heater (SAHLSE) were realized in the Thermal Processes Laboratory in the Research and Technology Center of Energy of Borj Cédria in Tunisia. The solar heating with thermal energy storage enhanced the microclimate of the greenhouse and the temperature didn’t drop less than 32 and 15°C respectively the day and at night. The realized solar collector with thermal latent storage offered higher temperature even when the sun is unavailable and increased the internal temperature by more than 5°C. The studied solar system realized good improvement in the hydroponic greenhouse and appeared to be a beneficial alternative for ensuring optimal microclimate.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Modular Energy Systems in Vehicular Applications A Pentacene -Based Organic Mis Structures Experimental Study of the Combined RES-Based Generators and Electric Storage Systems for Public Buildings An experimental study of the performance of the solar cell with heat sink cooling system Cooperative Operation of Parallel Connected Boost Converters for Low Voltage-High Power Applications: An Experimental Approach
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1