基于SOGI和级联DSC的正负序分量分离及其在不平衡PWM整流器上的应用

Cheng Qiming, Tan Fengren, Gao Jie, Zhang Yu, Yu Deqing
{"title":"基于SOGI和级联DSC的正负序分量分离及其在不平衡PWM整流器上的应用","authors":"Cheng Qiming, Tan Fengren, Gao Jie, Zhang Yu, Yu Deqing","doi":"10.1109/CCDC.2017.7978204","DOIUrl":null,"url":null,"abstract":"The second-order generalized integrator (SOGI) and cascade delayed signal cancellation (DSC) have been used respectively in the separation of positive and negative component. But they have their own disadvantages. In order to extract grid's positive and negative sequence fundamental component from unbalanced power system, the strategy of second-order generalized integrator eliminating higher harmonic and cascade delayed signal cancellation eliminating the specific frequency harmonic has been put forward in this article. It can quickly and accurately separate the positive and negative sequence fundamental component of the grid While grid voltage is distortion, symmetrical fault and asymmetric fault cases. Then, this new method is applied to unbalanced PWM rectifier.","PeriodicalId":6588,"journal":{"name":"2017 29th Chinese Control And Decision Conference (CCDC)","volume":"14 1","pages":"5804-5808"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"The separation of positive and negative sequence component based on SOGI and cascade DSC and its application at unbalanced PWM rectifier\",\"authors\":\"Cheng Qiming, Tan Fengren, Gao Jie, Zhang Yu, Yu Deqing\",\"doi\":\"10.1109/CCDC.2017.7978204\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The second-order generalized integrator (SOGI) and cascade delayed signal cancellation (DSC) have been used respectively in the separation of positive and negative component. But they have their own disadvantages. In order to extract grid's positive and negative sequence fundamental component from unbalanced power system, the strategy of second-order generalized integrator eliminating higher harmonic and cascade delayed signal cancellation eliminating the specific frequency harmonic has been put forward in this article. It can quickly and accurately separate the positive and negative sequence fundamental component of the grid While grid voltage is distortion, symmetrical fault and asymmetric fault cases. Then, this new method is applied to unbalanced PWM rectifier.\",\"PeriodicalId\":6588,\"journal\":{\"name\":\"2017 29th Chinese Control And Decision Conference (CCDC)\",\"volume\":\"14 1\",\"pages\":\"5804-5808\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 29th Chinese Control And Decision Conference (CCDC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CCDC.2017.7978204\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 29th Chinese Control And Decision Conference (CCDC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCDC.2017.7978204","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

二阶广义积分器(SOGI)和级联延迟信号对消(DSC)分别用于正负分量的分离。但它们也有自己的缺点。为了从不平衡电力系统中提取电网的正负序基分量,本文提出了二阶广义积分器消除高次谐波和级联延迟信号对消消除特定频率谐波的策略。该方法能够在电网电压出现畸变、对称故障和不对称故障的情况下,快速准确地分离出电网的正、负序基分量。然后,将该方法应用于不平衡PWM整流器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The separation of positive and negative sequence component based on SOGI and cascade DSC and its application at unbalanced PWM rectifier
The second-order generalized integrator (SOGI) and cascade delayed signal cancellation (DSC) have been used respectively in the separation of positive and negative component. But they have their own disadvantages. In order to extract grid's positive and negative sequence fundamental component from unbalanced power system, the strategy of second-order generalized integrator eliminating higher harmonic and cascade delayed signal cancellation eliminating the specific frequency harmonic has been put forward in this article. It can quickly and accurately separate the positive and negative sequence fundamental component of the grid While grid voltage is distortion, symmetrical fault and asymmetric fault cases. Then, this new method is applied to unbalanced PWM rectifier.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
UPQC Harmonic Detection Algorithm Based on Improved p-q Theory and Design of Low-Pass Filter Online parameters updating method for least squares support vector machine using Unscented Kalman filter Quadratic stabilization and L2 gain analysis of switched affine systems 3PL inventory pledge decision analysis under the unified credit logistics model Design and implementation of LiDAR navigation system based on triangulation measurement
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1