与纯音测听法比较,重新测试了Audioscan和bsamuys的信度和效度

W. Ishak, Fei Zhao, D. Stephens, J. Culling, Z. Bai, C. Meyer-bisch
{"title":"与纯音测听法比较,重新测试了Audioscan和bsamuys的信度和效度","authors":"W. Ishak, Fei Zhao, D. Stephens, J. Culling, Z. Bai, C. Meyer-bisch","doi":"10.3109/1651386X.2010.537124","DOIUrl":null,"url":null,"abstract":"Abstract Objective: With the development of more sophisticated and sensitive measures of auditory dysfunction, both the Audioscan test and Békésy audiometry can provide detailed information on hearing status between the octaves, which has clinical importance. This study investigated the reliability and validity of Audioscan and Békésy audiometry. Method: Audioscan and Bekesy audiometry were undertaken at a comparable sweep rate in 21 subjects with normal hearing. Each subject underwent conventional pure tone audiometry, Audioscan and Békésy audiometry. Test sessions were conducted on four consecutive days. Results: The results indicate that more than 90% of participants had variability of hearing threshold of less than 10dB at all frequencies. Median variances for thresholds obtained from Audioscan were less than 10dB2 for all frequencies except 4.0 kHz. In contrast, thresholds obtained from Békésy showed greater variance, more than 15dB2 at all frequencies when it was undertaken at the same sweep rate. Audioscan results were in excellent agreement with the PTA at all frequencies except at 0.25, 6 and 8 kHz, whereas Békésy results differed significantly from PTA at all frequencies except at 6 kHz. Conclusion: Data from the present study indicate that the Audioscan can provide reliable and valid hearing thresholds. However, a slow sweep rate appears to be more desirable for Békésy audiometry to improve its reliability and validity in detecting hearing sensitivity.","PeriodicalId":88223,"journal":{"name":"Audiological medicine","volume":"260 1","pages":"40 - 46"},"PeriodicalIF":0.0000,"publicationDate":"2011-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Test-retest reliability and validity of Audioscan and Békésy compared with pure tone audiometry\",\"authors\":\"W. Ishak, Fei Zhao, D. Stephens, J. Culling, Z. Bai, C. Meyer-bisch\",\"doi\":\"10.3109/1651386X.2010.537124\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Objective: With the development of more sophisticated and sensitive measures of auditory dysfunction, both the Audioscan test and Békésy audiometry can provide detailed information on hearing status between the octaves, which has clinical importance. This study investigated the reliability and validity of Audioscan and Békésy audiometry. Method: Audioscan and Bekesy audiometry were undertaken at a comparable sweep rate in 21 subjects with normal hearing. Each subject underwent conventional pure tone audiometry, Audioscan and Békésy audiometry. Test sessions were conducted on four consecutive days. Results: The results indicate that more than 90% of participants had variability of hearing threshold of less than 10dB at all frequencies. Median variances for thresholds obtained from Audioscan were less than 10dB2 for all frequencies except 4.0 kHz. In contrast, thresholds obtained from Békésy showed greater variance, more than 15dB2 at all frequencies when it was undertaken at the same sweep rate. Audioscan results were in excellent agreement with the PTA at all frequencies except at 0.25, 6 and 8 kHz, whereas Békésy results differed significantly from PTA at all frequencies except at 6 kHz. Conclusion: Data from the present study indicate that the Audioscan can provide reliable and valid hearing thresholds. However, a slow sweep rate appears to be more desirable for Békésy audiometry to improve its reliability and validity in detecting hearing sensitivity.\",\"PeriodicalId\":88223,\"journal\":{\"name\":\"Audiological medicine\",\"volume\":\"260 1\",\"pages\":\"40 - 46\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-02-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Audiological medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/1651386X.2010.537124\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiological medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/1651386X.2010.537124","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

摘要目的:随着听觉功能障碍检测手段的发展,Audioscan测试和bsamk听力测量法均能提供八度音阶间的详细听力信息,具有重要的临床意义。本研究考察了Audioscan和bsamksamsy听力学的信度和效度。方法:对21名听力正常的受试者进行听力扫描和Bekesy听力测量。每个受试者都进行了常规纯音测听、Audioscan测听和b忧郁测听。测试阶段连续进行4天。结果:90%以上的被试在所有频率下的听阈变异性均小于10dB。除4.0 kHz外,Audioscan获得的阈值的中位数方差小于10dB2。相比之下,从bsamksamsy获得的阈值显示出更大的差异,当以相同的扫描速率进行时,在所有频率上都超过15dB2。除0.25、6和8 kHz外,音频扫描结果与PTA在所有频率上都非常一致,而bsamksamsy的结果与PTA在除6 kHz外的所有频率上都有显著差异。结论:本研究数据表明,Audioscan可以提供可靠有效的听力阈值。然而,较慢的扫描速率似乎是更理想的,以提高其在检测听觉灵敏度的可靠性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Test-retest reliability and validity of Audioscan and Békésy compared with pure tone audiometry
Abstract Objective: With the development of more sophisticated and sensitive measures of auditory dysfunction, both the Audioscan test and Békésy audiometry can provide detailed information on hearing status between the octaves, which has clinical importance. This study investigated the reliability and validity of Audioscan and Békésy audiometry. Method: Audioscan and Bekesy audiometry were undertaken at a comparable sweep rate in 21 subjects with normal hearing. Each subject underwent conventional pure tone audiometry, Audioscan and Békésy audiometry. Test sessions were conducted on four consecutive days. Results: The results indicate that more than 90% of participants had variability of hearing threshold of less than 10dB at all frequencies. Median variances for thresholds obtained from Audioscan were less than 10dB2 for all frequencies except 4.0 kHz. In contrast, thresholds obtained from Békésy showed greater variance, more than 15dB2 at all frequencies when it was undertaken at the same sweep rate. Audioscan results were in excellent agreement with the PTA at all frequencies except at 0.25, 6 and 8 kHz, whereas Békésy results differed significantly from PTA at all frequencies except at 6 kHz. Conclusion: Data from the present study indicate that the Audioscan can provide reliable and valid hearing thresholds. However, a slow sweep rate appears to be more desirable for Békésy audiometry to improve its reliability and validity in detecting hearing sensitivity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Referees Morphological and functional structure of the inner ear: Its relation to Ménière's disease Medical therapy in Ménière's disease Simon Dafydd Glyn Stephens, Professor of Audiological Medicine Ménière's disorder: A short history
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1