{"title":"案例研究-识别和修复复杂涡轮机械驱动器错位的影响因素","authors":"A. Manikandan, Zeeshan Anwar","doi":"10.2118/192641-MS","DOIUrl":null,"url":null,"abstract":"\n Turbo machineries are considered as one of the most critical equipment in oil, gas and petrochemical plants which needs highly safe and reliable operation. Generally, turbomachineries will be driven by Electric motor or steam turbine or gas turbine in process plant which depends upon the application. This case study represents an experience on complex turbo machinery driver misalignment which is electric motor. In this specific case, electric motor drives Gearbox and centrifugal compressor. Centrifugalcompressor is used for process gas pressurisation. This misalignment was observed between electric motor and gearbox.\n Electric motors are basically electrical machines which converts electric energy into mechanical energy. So, they are used as driver to drive gearboxes, compressors or pumps and other machines. These machineries have rotating parts at hot at high speed.\n While units are in new installation phase, machinery alignment shall be performed between the driver and driven machineries. Unlike other rotating machines, electric motors have high thrust clearance. During operation rotor will come to magnetic centre. Prior to the installation of coupling solo run will be performed on the motor to evaluate the performance of motor and to ensure the magnetic centre.","PeriodicalId":11014,"journal":{"name":"Day 1 Mon, November 12, 2018","volume":"23 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Case Study – To Identify and Fix the Contributing Factors on a Complex Turbo Machinery Driver Misalignment\",\"authors\":\"A. Manikandan, Zeeshan Anwar\",\"doi\":\"10.2118/192641-MS\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Turbo machineries are considered as one of the most critical equipment in oil, gas and petrochemical plants which needs highly safe and reliable operation. Generally, turbomachineries will be driven by Electric motor or steam turbine or gas turbine in process plant which depends upon the application. This case study represents an experience on complex turbo machinery driver misalignment which is electric motor. In this specific case, electric motor drives Gearbox and centrifugal compressor. Centrifugalcompressor is used for process gas pressurisation. This misalignment was observed between electric motor and gearbox.\\n Electric motors are basically electrical machines which converts electric energy into mechanical energy. So, they are used as driver to drive gearboxes, compressors or pumps and other machines. These machineries have rotating parts at hot at high speed.\\n While units are in new installation phase, machinery alignment shall be performed between the driver and driven machineries. Unlike other rotating machines, electric motors have high thrust clearance. During operation rotor will come to magnetic centre. Prior to the installation of coupling solo run will be performed on the motor to evaluate the performance of motor and to ensure the magnetic centre.\",\"PeriodicalId\":11014,\"journal\":{\"name\":\"Day 1 Mon, November 12, 2018\",\"volume\":\"23 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Day 1 Mon, November 12, 2018\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2118/192641-MS\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Day 1 Mon, November 12, 2018","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2118/192641-MS","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

涡轮机械是石油、天然气和石化装置中最关键的设备之一,对其运行的安全性和可靠性要求很高。一般情况下,在加工装置中,涡轮机械将根据应用情况由电动机或蒸汽轮机或燃气轮机驱动。本案例研究反映了复杂涡轮机械中电机驱动错位的经验。在这种具体情况下,电动机驱动变速箱和离心式压缩机。离心压缩机用于工艺气体增压。在电动机和齿轮箱之间观察到这种不对中现象。电动机基本上是把电能转化为机械能的电机。因此,它们被用作驱动齿轮箱、压缩机或泵和其他机器的驱动器。这些机器有高速旋转的零件。当机组处于新安装阶段时,应在驱动机器和被驱动机器之间进行机械校准。与其他旋转机器不同,电动机有很高的推力间隙。在运行过程中,转子会来到磁中心。在安装联轴器之前,将对电机进行单独运行,以评估电机的性能并确保磁心。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Case Study – To Identify and Fix the Contributing Factors on a Complex Turbo Machinery Driver Misalignment
Turbo machineries are considered as one of the most critical equipment in oil, gas and petrochemical plants which needs highly safe and reliable operation. Generally, turbomachineries will be driven by Electric motor or steam turbine or gas turbine in process plant which depends upon the application. This case study represents an experience on complex turbo machinery driver misalignment which is electric motor. In this specific case, electric motor drives Gearbox and centrifugal compressor. Centrifugalcompressor is used for process gas pressurisation. This misalignment was observed between electric motor and gearbox. Electric motors are basically electrical machines which converts electric energy into mechanical energy. So, they are used as driver to drive gearboxes, compressors or pumps and other machines. These machineries have rotating parts at hot at high speed. While units are in new installation phase, machinery alignment shall be performed between the driver and driven machineries. Unlike other rotating machines, electric motors have high thrust clearance. During operation rotor will come to magnetic centre. Prior to the installation of coupling solo run will be performed on the motor to evaluate the performance of motor and to ensure the magnetic centre.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Does the kappa number method accurately reflect lignin content in nonwood pulps? Using multistage models to evaluate how pulp washing after the first extraction stage impacts elemental chlorine-free bleach demand Understanding the risks and rewards of using 50% vs. 10% strength peroxide in pulp bleach plants Understanding the pulping and bleaching performances of eucalyptus woods affected by physiological disturbance Measurements of the Inorganic Scale Buildup Rate on Downhole Completion Equipment – Debris Barrier Screens
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1