ProTaper Next与2Shape镍钛锉在模拟严重弯曲管中的成形能力比较

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Giornale Italiano di Endodonzia Pub Date : 2018-11-01 DOI:10.1016/j.gien.2018.05.002
Simone Staffoli , Taha Özyürek , Avi Hadad , Alex Lvovsky , Michael Solomonov , Hadas Azizi , Joe Ben Itzhak , Maurizo Bossù , Nicola M. Grande , Gianluca Plotino , Antonella Polimeni
{"title":"ProTaper Next与2Shape镍钛锉在模拟严重弯曲管中的成形能力比较","authors":"Simone Staffoli ,&nbsp;Taha Özyürek ,&nbsp;Avi Hadad ,&nbsp;Alex Lvovsky ,&nbsp;Michael Solomonov ,&nbsp;Hadas Azizi ,&nbsp;Joe Ben Itzhak ,&nbsp;Maurizo Bossù ,&nbsp;Nicola M. Grande ,&nbsp;Gianluca Plotino ,&nbsp;Antonella Polimeni","doi":"10.1016/j.gien.2018.05.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Aim</h3><p>To evaluate the centering ability of ProTaper Next (PTN) and 2Shape (TS) nickel–titanium (NiTi) instruments in terms of maintaining the original root canal configuration in a simulated tooth with severe curvature.</p></div><div><h3>Methodology</h3><p>Twenty standardized simulated curved root canals were prepared to an apical size of 0.25<!--> <!-->mm using PTN and TS (<em>n</em> <!-->=<!--> <!-->10 canal/group) nickel-titanium files. A gig was constructed to enable reproducible image acquisition using a photographic camera. Pre- and post-instrumented images were recorded and superimposed using a computer software. The ability of the instruments to remain centered in the canal was determined by calculating a centering ratio at three independent points of the simulated canal: coronal, middle and apical third of the curvature, using a computer software. Statistical analysis was performed using one-way analysis of variance (ANOVA) followed by independent sample <em>t</em>-test at 5% significance level.</p></div><div><h3>Results</h3><p>No significant difference was found between the two systems (<em>p</em> <!-->&gt;<!--> <!-->0.05). At the apical third, the mean centering ratio was significantly higher than the centering ratio of the coronal and the middle thirds in both TS and PTN (<em>p</em> <!-->&lt;<!--> <!-->0.05).</p></div><div><h3>Conclusions</h3><p>There were no significant differences in the centering ability of the ProTaper Next and 2Shape systems in simulated severe curved canals. Both systems exhibited some degree of transportation, especially in the apical third.</p></div>","PeriodicalId":42221,"journal":{"name":"Giornale Italiano di Endodonzia","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.gien.2018.05.002","citationCount":"8","resultStr":"{\"title\":\"Comparison of shaping ability of ProTaper Next and 2Shape nickel–titanium files in simulated severe curved canals\",\"authors\":\"Simone Staffoli ,&nbsp;Taha Özyürek ,&nbsp;Avi Hadad ,&nbsp;Alex Lvovsky ,&nbsp;Michael Solomonov ,&nbsp;Hadas Azizi ,&nbsp;Joe Ben Itzhak ,&nbsp;Maurizo Bossù ,&nbsp;Nicola M. Grande ,&nbsp;Gianluca Plotino ,&nbsp;Antonella Polimeni\",\"doi\":\"10.1016/j.gien.2018.05.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Aim</h3><p>To evaluate the centering ability of ProTaper Next (PTN) and 2Shape (TS) nickel–titanium (NiTi) instruments in terms of maintaining the original root canal configuration in a simulated tooth with severe curvature.</p></div><div><h3>Methodology</h3><p>Twenty standardized simulated curved root canals were prepared to an apical size of 0.25<!--> <!-->mm using PTN and TS (<em>n</em> <!-->=<!--> <!-->10 canal/group) nickel-titanium files. A gig was constructed to enable reproducible image acquisition using a photographic camera. Pre- and post-instrumented images were recorded and superimposed using a computer software. The ability of the instruments to remain centered in the canal was determined by calculating a centering ratio at three independent points of the simulated canal: coronal, middle and apical third of the curvature, using a computer software. Statistical analysis was performed using one-way analysis of variance (ANOVA) followed by independent sample <em>t</em>-test at 5% significance level.</p></div><div><h3>Results</h3><p>No significant difference was found between the two systems (<em>p</em> <!-->&gt;<!--> <!-->0.05). At the apical third, the mean centering ratio was significantly higher than the centering ratio of the coronal and the middle thirds in both TS and PTN (<em>p</em> <!-->&lt;<!--> <!-->0.05).</p></div><div><h3>Conclusions</h3><p>There were no significant differences in the centering ability of the ProTaper Next and 2Shape systems in simulated severe curved canals. Both systems exhibited some degree of transportation, especially in the apical third.</p></div>\",\"PeriodicalId\":42221,\"journal\":{\"name\":\"Giornale Italiano di Endodonzia\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2018-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.gien.2018.05.002\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Giornale Italiano di Endodonzia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S112141711830013X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Giornale Italiano di Endodonzia","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S112141711830013X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 8

摘要

目的评价ProTaper Next (PTN)和2Shape (TS)镍钛(NiTi)器械在严重弯曲模拟牙中维持根管形态的对中能力。方法采用PTN和TS (n = 10根/组)镍钛锉制备标准化的模拟弯曲根管20根,根尖尺寸为0.25 mm。构造了一个gig,以便使用照相机进行可重复的图像采集。使用计算机软件记录和叠加仪器前和仪器后的图像。通过计算机软件计算模拟根管的三个独立点(冠状、中间和根尖曲率的三分之一)的定心比,确定了器械在根管内保持中心的能力。统计学分析采用单因素方差分析(ANOVA),并在5%显著性水平下进行独立样本t检验。结果两种系统间无显著差异(p >0.05)。在根尖三分之一,TS和PTN的平均定心率显著高于冠状和中三分之一(p <0.05)。结论ProTaper Next和2Shape系统在模拟严重弯曲根管的对中能力无显著差异。两个系统都表现出一定程度的迁移,尤其是在顶端三分之一。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of shaping ability of ProTaper Next and 2Shape nickel–titanium files in simulated severe curved canals

Aim

To evaluate the centering ability of ProTaper Next (PTN) and 2Shape (TS) nickel–titanium (NiTi) instruments in terms of maintaining the original root canal configuration in a simulated tooth with severe curvature.

Methodology

Twenty standardized simulated curved root canals were prepared to an apical size of 0.25 mm using PTN and TS (n = 10 canal/group) nickel-titanium files. A gig was constructed to enable reproducible image acquisition using a photographic camera. Pre- and post-instrumented images were recorded and superimposed using a computer software. The ability of the instruments to remain centered in the canal was determined by calculating a centering ratio at three independent points of the simulated canal: coronal, middle and apical third of the curvature, using a computer software. Statistical analysis was performed using one-way analysis of variance (ANOVA) followed by independent sample t-test at 5% significance level.

Results

No significant difference was found between the two systems (p > 0.05). At the apical third, the mean centering ratio was significantly higher than the centering ratio of the coronal and the middle thirds in both TS and PTN (p < 0.05).

Conclusions

There were no significant differences in the centering ability of the ProTaper Next and 2Shape systems in simulated severe curved canals. Both systems exhibited some degree of transportation, especially in the apical third.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Giornale Italiano di Endodonzia
Giornale Italiano di Endodonzia DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
0.90
自引率
25.00%
发文量
0
审稿时长
24 weeks
期刊介绍: The Giornale Italiano di Endodonzia was founded in 1987 and is the official journal of the Italian Society of Endodontics (SIE). It is a peer-reviewed journal publishing original articles on clinical research and/or clinical methodology, case reports related to Endodontics. The Journal evaluates also contributes in restorative dentistry, dental traumatology, experimental pathophysiology, pharmacology and microbiology dealing with Endodontics.
期刊最新文献
Comparative efficacy of Depotphoresis and diode laser for reduction of microbial load and postoperative pain, and healing of periapical lesions: a randomized clinical trial Endodontics: clinical protocols on scientific basis Anatomical proximity of upper teeth and local factors associated with the thickness of the maxillary sinus membrane: a retrospective study A contemporary approach to treat necrotic immature teeth using different bioceramic materials Endodontic guides and ultrasonic tips for management of calcifications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1