{"title":"车间工业网络电力损耗计算可能存在的误差","authors":"E. Gracheva, A. Alimova","doi":"10.30724/1998-9903-2018-20-11-12-81-92","DOIUrl":null,"url":null,"abstract":"In the article it is devoted the analysis and researches of origins and values of possible errors from not accounting of the main defining characteristics when calculating losses of the electric power on shop networks of a low tension. It is proved that in case of determination of losses of the electric power in lines of shop networks it is necessary to consider influence of the following parameters of the equipment: the heating of conductors caused by passing of current of loading through conductors and ambient temperature; resistance of contact joints of switching devices and their number; type of the load graph; ambient temperatures. The diagram of a shop network and daily load graphs of customers of one of the enterprises is researched. Errors of calculations of losses of the electric power are calculated and the analysis of influence of parameters of the equipment on value of losses of the electric power is carried out. The absence of reliable information about elements of shop networks of a low tension and not accounting of the determining leads to an error 5 - 80% in case of computation of losses of the electric power in the systems of industrial electrical power supply.","PeriodicalId":33495,"journal":{"name":"Izvestiia vysshikh uchebnykh zavedenii Problemy energetiki","volume":"43 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"POSSIBLE ERRORS OF CALCULATIONS OF LOSSES OF THE ELECTRIC POWER ON SHOP INDUSTRIAL NETWORKS\",\"authors\":\"E. Gracheva, A. Alimova\",\"doi\":\"10.30724/1998-9903-2018-20-11-12-81-92\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the article it is devoted the analysis and researches of origins and values of possible errors from not accounting of the main defining characteristics when calculating losses of the electric power on shop networks of a low tension. It is proved that in case of determination of losses of the electric power in lines of shop networks it is necessary to consider influence of the following parameters of the equipment: the heating of conductors caused by passing of current of loading through conductors and ambient temperature; resistance of contact joints of switching devices and their number; type of the load graph; ambient temperatures. The diagram of a shop network and daily load graphs of customers of one of the enterprises is researched. Errors of calculations of losses of the electric power are calculated and the analysis of influence of parameters of the equipment on value of losses of the electric power is carried out. The absence of reliable information about elements of shop networks of a low tension and not accounting of the determining leads to an error 5 - 80% in case of computation of losses of the electric power in the systems of industrial electrical power supply.\",\"PeriodicalId\":33495,\"journal\":{\"name\":\"Izvestiia vysshikh uchebnykh zavedenii Problemy energetiki\",\"volume\":\"43 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Izvestiia vysshikh uchebnykh zavedenii Problemy energetiki\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30724/1998-9903-2018-20-11-12-81-92\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Izvestiia vysshikh uchebnykh zavedenii Problemy energetiki","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30724/1998-9903-2018-20-11-12-81-92","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文分析和研究了在计算低压电网的电力损耗时,由于不考虑主要定义特性而可能产生的误差的来源和值。证明了在确定车间电网线路的电力损耗时,必须考虑以下设备参数的影响:负载电流通过导线引起的导线发热和环境温度;开关器件接触接头的电阻及其数量;荷载图类型;环境温度。研究了某企业的店铺网络图和顾客日负荷图。对电力损耗计算误差进行了计算,分析了设备参数对电力损耗值的影响。在工业供电系统中,由于缺乏可靠的低压电网元件信息和不考虑确定因素,导致在计算电力损耗时误差达5 - 80%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
POSSIBLE ERRORS OF CALCULATIONS OF LOSSES OF THE ELECTRIC POWER ON SHOP INDUSTRIAL NETWORKS
In the article it is devoted the analysis and researches of origins and values of possible errors from not accounting of the main defining characteristics when calculating losses of the electric power on shop networks of a low tension. It is proved that in case of determination of losses of the electric power in lines of shop networks it is necessary to consider influence of the following parameters of the equipment: the heating of conductors caused by passing of current of loading through conductors and ambient temperature; resistance of contact joints of switching devices and their number; type of the load graph; ambient temperatures. The diagram of a shop network and daily load graphs of customers of one of the enterprises is researched. Errors of calculations of losses of the electric power are calculated and the analysis of influence of parameters of the equipment on value of losses of the electric power is carried out. The absence of reliable information about elements of shop networks of a low tension and not accounting of the determining leads to an error 5 - 80% in case of computation of losses of the electric power in the systems of industrial electrical power supply.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
90
审稿时长
8 weeks
期刊最新文献
INDICATORS OF ENERGY AND SEPARATION EFFICIENCY OF GAS SEPARATORS INTENDED TO REMOVE AEROSOL DROPLETS EVALUATION OF THE PERFORMANCE AND ENERGY EFFICIENCY OF INTEGRATED SOLAR COMBINED CYCLE POWER PLANT LED SOURCE OF LIGHT WITH HIGH LIGHT CIRCUIT IMPROVEMENT OF TRANSIENT STABILITY OF AUTONOMOUS POWER SYSTEM ON BASIS OF WIDE AREA CONTROL SYSTEM OPTIMIZE THE PERFORMANCE OF ELECTRICAL EQUIPMENT IN GAS SEPARATION STATIONS (DEGASSING STATION DS ) AND ELECTRICAL SUBMERSIBLE PUMPS OF OIL EQUIPMENT FOR OIL RUMAILA FIELD
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1