滴管测定液体表面张力的准确度分析及其随分离时间和倾斜角度的变化规律

Priyanka Thakral, M. Sharma, Diksha Dewan, Sakshi Sharma
{"title":"滴管测定液体表面张力的准确度分析及其随分离时间和倾斜角度的变化规律","authors":"Priyanka Thakral, M. Sharma, Diksha Dewan, Sakshi Sharma","doi":"10.56042/ijca.v59i11.36247","DOIUrl":null,"url":null,"abstract":"A simple laboratory experiment to measure the surface tension of liquids has been proposed in this work, which is well suited for any undergraduate laboratory demonstration. Burette with modified Tate’s law has been found to return surface tension values as good as those obtained using Traube’s stalagmometer. Experimental data and error analysis show similar result accuracy. Also, a comparative study brings to notice the exactitude of drop weight method over drop number method, both from stalagmometer and burette. The rate of flow of 11–23 drops per minute has been found to be highly suitable for minimization of errors due to evaporation and satellite drop formation. Angular dependence of surface tension has been proposed numerically and validated for the respective case with the angle of 0° to deviate the least from literature value. The results obtained in this study are synchronous with the established theoretical understanding of the concept.","PeriodicalId":54992,"journal":{"name":"Indian Journal of Chemistry Section A-Inorganic Bio-Inorganic Physical Theoretical & Analytical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2020-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Analysis of accuracy of burette in determination of surface tension of liquids and study of its variation with detachment time and inclination angle\",\"authors\":\"Priyanka Thakral, M. Sharma, Diksha Dewan, Sakshi Sharma\",\"doi\":\"10.56042/ijca.v59i11.36247\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A simple laboratory experiment to measure the surface tension of liquids has been proposed in this work, which is well suited for any undergraduate laboratory demonstration. Burette with modified Tate’s law has been found to return surface tension values as good as those obtained using Traube’s stalagmometer. Experimental data and error analysis show similar result accuracy. Also, a comparative study brings to notice the exactitude of drop weight method over drop number method, both from stalagmometer and burette. The rate of flow of 11–23 drops per minute has been found to be highly suitable for minimization of errors due to evaporation and satellite drop formation. Angular dependence of surface tension has been proposed numerically and validated for the respective case with the angle of 0° to deviate the least from literature value. The results obtained in this study are synchronous with the established theoretical understanding of the concept.\",\"PeriodicalId\":54992,\"journal\":{\"name\":\"Indian Journal of Chemistry Section A-Inorganic Bio-Inorganic Physical Theoretical & Analytical Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2020-11-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Chemistry Section A-Inorganic Bio-Inorganic Physical Theoretical & Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.56042/ijca.v59i11.36247\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Chemistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Chemistry Section A-Inorganic Bio-Inorganic Physical Theoretical & Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.56042/ijca.v59i11.36247","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 1

摘要

在这项工作中提出了一个简单的实验室实验来测量液体的表面张力,这非常适合任何本科实验室演示。经修正的泰特定律所得到的表面张力值与用特劳布石笋计得到的表面张力值一样好。实验数据和误差分析表明结果具有相似的准确性。同时,通过对比研究发现,从石笋计和滴管的角度出发,液滴重量法比液滴数法的准确性更高。人们发现,每分钟11-23滴的流速非常适合于使由于蒸发和卫星液滴形成引起的误差最小化。用数值方法提出了表面张力的角依赖性,并对0°角与文献值偏差最小的情况进行了验证。本研究得到的结果与已建立的对该概念的理论认识是一致的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of accuracy of burette in determination of surface tension of liquids and study of its variation with detachment time and inclination angle
A simple laboratory experiment to measure the surface tension of liquids has been proposed in this work, which is well suited for any undergraduate laboratory demonstration. Burette with modified Tate’s law has been found to return surface tension values as good as those obtained using Traube’s stalagmometer. Experimental data and error analysis show similar result accuracy. Also, a comparative study brings to notice the exactitude of drop weight method over drop number method, both from stalagmometer and burette. The rate of flow of 11–23 drops per minute has been found to be highly suitable for minimization of errors due to evaporation and satellite drop formation. Angular dependence of surface tension has been proposed numerically and validated for the respective case with the angle of 0° to deviate the least from literature value. The results obtained in this study are synchronous with the established theoretical understanding of the concept.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
1
审稿时长
6-12 weeks
期刊介绍: Information not localized
期刊最新文献
DFT, TD-DFT and Biological Activity Studies of Some Maleanilic Acid Derivatives Ligands and Their Organometallic Complexes Application value of Co(II) coordination polymer in the treatment and operational nursing of hypothermia Mixed ligand complex of monovalent Copper with benzimidazole derivatives and alanine: synthesis, characterization and antimicrobial studies New Mn(II)-coordination polymer based on flexible benzimidazol ligand: crystal structure and treatment on osteosarcoma Syntheses, crystal structures and properties of three compounds based on the dicarboxylate ligand with S-S flexible linkage
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1