D. Palamattam, S. Moningi, D. Kulkarni, G. Ramachandran
{"title":"连续心输出量监测对脑动脉瘤破裂伴主动脉瓣狭窄的血流动力学治疗","authors":"D. Palamattam, S. Moningi, D. Kulkarni, G. Ramachandran","doi":"10.4103/2394-6954.180652","DOIUrl":null,"url":null,"abstract":"The perioperative management of a patient diagnosed with ruptured cerebral aneurysm and aortic stenosis (AS) is a challenging task for the anesthesiologist. Continuous cardiac output (CO) monitoring devices such as the FloTrac™/Vigileo™ system is a reliable measure to avoid and minimize the adverse complications of hemodynamic instability, thus favoring the outcome.","PeriodicalId":17751,"journal":{"name":"Karnataka Anaesthesia Journal","volume":"11 1","pages":"199 - 201"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Continuous cardiac output monitoring for hemodynamic management of a case of ruptured cerebral artery aneurysm with aortic stenosis\",\"authors\":\"D. Palamattam, S. Moningi, D. Kulkarni, G. Ramachandran\",\"doi\":\"10.4103/2394-6954.180652\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The perioperative management of a patient diagnosed with ruptured cerebral aneurysm and aortic stenosis (AS) is a challenging task for the anesthesiologist. Continuous cardiac output (CO) monitoring devices such as the FloTrac™/Vigileo™ system is a reliable measure to avoid and minimize the adverse complications of hemodynamic instability, thus favoring the outcome.\",\"PeriodicalId\":17751,\"journal\":{\"name\":\"Karnataka Anaesthesia Journal\",\"volume\":\"11 1\",\"pages\":\"199 - 201\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Karnataka Anaesthesia Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/2394-6954.180652\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Karnataka Anaesthesia Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/2394-6954.180652","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Continuous cardiac output monitoring for hemodynamic management of a case of ruptured cerebral artery aneurysm with aortic stenosis
The perioperative management of a patient diagnosed with ruptured cerebral aneurysm and aortic stenosis (AS) is a challenging task for the anesthesiologist. Continuous cardiac output (CO) monitoring devices such as the FloTrac™/Vigileo™ system is a reliable measure to avoid and minimize the adverse complications of hemodynamic instability, thus favoring the outcome.