{"title":"高分子植入物在大型生物组织反应研究中的植入位置选择","authors":"V. A. Lipatov, D. A. Severinov, M. D. Naimzada","doi":"10.23888/pavlovj2019274503-511","DOIUrl":null,"url":null,"abstract":"Aim. Assessment of different methods of implantation and autopsy of portions of tissue at the sites of insertion of polymer implants. Materials and Methods . Samples of new vessel prostheses (OOO Lintex, Saint Petersburg) were implanted into the subcutaneous layer of the abdominal wall and paravertebral area of 30 rats. Morphological changes at the sites of insertion of implants, and also variation of the values of criteria developed by the authors were evaluated. The results obtained in studies, were evaluated by experts on the basis of the evidence of artefacts in microphotographs, of expected probability for damage to the implant bed in the experiment and in autopsy, of expected technical complexity of getting a sample of the implant and of the periprosthetic capsule in autopsy. Results. The total score of evaluated tissue reactions reached the highest meanings (59) in the group of laboratory animals where the tested samples were implanted into the subcutaneous tissue of the back, which determines this method as least preferable. Variability and error of the method of subcutaneous implantation was higher in the group with implantation of samples into the paravertebral area, since the values of standard deviation (m) in histological examination of this group (from 0.89 to 3.64) exceeded deviations in animals with implantation of the tested prosthetic implants into the abdominal wall (from 0.25 to 2.54). Conclusion. Implantation in the area of the abdominal wall is characterized by lower variability of standard deviation (m) of the morphometric parameters, by lower number of artefacts and by almost complete absence of technical complications in autopsy of the studied material, which, in the opinion of the authors, gives preference to this method in experimental research.","PeriodicalId":13184,"journal":{"name":"I.P.Pavlov Russian Medical Biological Herald","volume":"65 5 1","pages":"503-511"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"More on choice of places for insertion of tested samples of polymer implants in study of reaction of tissues of macroorganism\",\"authors\":\"V. A. Lipatov, D. A. Severinov, M. D. Naimzada\",\"doi\":\"10.23888/pavlovj2019274503-511\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Aim. Assessment of different methods of implantation and autopsy of portions of tissue at the sites of insertion of polymer implants. Materials and Methods . Samples of new vessel prostheses (OOO Lintex, Saint Petersburg) were implanted into the subcutaneous layer of the abdominal wall and paravertebral area of 30 rats. Morphological changes at the sites of insertion of implants, and also variation of the values of criteria developed by the authors were evaluated. The results obtained in studies, were evaluated by experts on the basis of the evidence of artefacts in microphotographs, of expected probability for damage to the implant bed in the experiment and in autopsy, of expected technical complexity of getting a sample of the implant and of the periprosthetic capsule in autopsy. Results. The total score of evaluated tissue reactions reached the highest meanings (59) in the group of laboratory animals where the tested samples were implanted into the subcutaneous tissue of the back, which determines this method as least preferable. Variability and error of the method of subcutaneous implantation was higher in the group with implantation of samples into the paravertebral area, since the values of standard deviation (m) in histological examination of this group (from 0.89 to 3.64) exceeded deviations in animals with implantation of the tested prosthetic implants into the abdominal wall (from 0.25 to 2.54). Conclusion. Implantation in the area of the abdominal wall is characterized by lower variability of standard deviation (m) of the morphometric parameters, by lower number of artefacts and by almost complete absence of technical complications in autopsy of the studied material, which, in the opinion of the authors, gives preference to this method in experimental research.\",\"PeriodicalId\":13184,\"journal\":{\"name\":\"I.P.Pavlov Russian Medical Biological Herald\",\"volume\":\"65 5 1\",\"pages\":\"503-511\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"I.P.Pavlov Russian Medical Biological Herald\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23888/pavlovj2019274503-511\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"I.P.Pavlov Russian Medical Biological Herald","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23888/pavlovj2019274503-511","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
的目标。不同植入方法的评估和聚合物植入部位部分组织的解剖。材料与方法。将新型血管假体(OOO Lintex, Saint Petersburg)样品植入30只大鼠腹壁皮下和椎旁区域。植入物插入部位的形态学变化,以及作者制定的标准值的变化进行了评估。在研究中获得的结果,由专家根据显微照片中的伪影证据,在实验和尸检中对植入物床损坏的预期概率,以及在尸检中获得植入物和假体周围胶囊样本的预期技术复杂性进行评估。结果。在将测试样本植入背部皮下组织的实验动物组中,评估组织反应的总分达到最高(59分),这决定了该方法是最不可取的。皮下植入方法的变异性和误差在椎旁区植入组中更高,因为该组组织学检查的标准差(m)值(从0.89到3.64)超过了将所测假体植入腹壁动物的偏差(从0.25到2.54)。结论。在腹壁区域植入的特点是形态测量参数的标准偏差(m)变异性较低,人工制品数量较少,并且在研究材料的解剖中几乎完全没有技术并发症,这在作者看来,在实验研究中优先采用这种方法。
More on choice of places for insertion of tested samples of polymer implants in study of reaction of tissues of macroorganism
Aim. Assessment of different methods of implantation and autopsy of portions of tissue at the sites of insertion of polymer implants. Materials and Methods . Samples of new vessel prostheses (OOO Lintex, Saint Petersburg) were implanted into the subcutaneous layer of the abdominal wall and paravertebral area of 30 rats. Morphological changes at the sites of insertion of implants, and also variation of the values of criteria developed by the authors were evaluated. The results obtained in studies, were evaluated by experts on the basis of the evidence of artefacts in microphotographs, of expected probability for damage to the implant bed in the experiment and in autopsy, of expected technical complexity of getting a sample of the implant and of the periprosthetic capsule in autopsy. Results. The total score of evaluated tissue reactions reached the highest meanings (59) in the group of laboratory animals where the tested samples were implanted into the subcutaneous tissue of the back, which determines this method as least preferable. Variability and error of the method of subcutaneous implantation was higher in the group with implantation of samples into the paravertebral area, since the values of standard deviation (m) in histological examination of this group (from 0.89 to 3.64) exceeded deviations in animals with implantation of the tested prosthetic implants into the abdominal wall (from 0.25 to 2.54). Conclusion. Implantation in the area of the abdominal wall is characterized by lower variability of standard deviation (m) of the morphometric parameters, by lower number of artefacts and by almost complete absence of technical complications in autopsy of the studied material, which, in the opinion of the authors, gives preference to this method in experimental research.