印度中部政府卫生保健设施中的不安全注射做法及其预测因素。

Aditya Thakur, M. Toppo, D. Pal
{"title":"印度中部政府卫生保健设施中的不安全注射做法及其预测因素。","authors":"Aditya Thakur, M. Toppo, D. Pal","doi":"10.5455/ijmrcr.172-1669868821","DOIUrl":null,"url":null,"abstract":"Introduction- Irrational and unsafe injection practices are Insidious in developing countries harming the patient and alluring risks to the health care workers. Poor injection practices, including injection overuse and unsafe practices have been reported in many developing and transitional countries Objective - To determine the proportion and predictors of unsafe injections practices in government health facilities. Material and method - It was a descriptive cross-sectional study done in duration of 6 months A sample of 280 was calculated and 83 injection units of 11 government health care facilities were considered for the assessment. Generation of descriptive Statistics was done. Chi-square test and multivariate logistic regression analysis was used to identify potential risk factor of unsafe injection practices. Result- 45 % of the injection practices out of total 280 observed injection practice in all the 11 facilities selected in study is found to be unsafe. Primary health care facilities were 2.13 times more likely to exhibit unsafe injection practice while secondary health care facilities were 1.45 times more prone to unsafe injection practice as compare to tertiary health care facilities. Conclusion- High frequency of noncompliance to best injection safety practices are widespread in the government facilities. This Situation is even worse in the primary health center and community health center.","PeriodicalId":13694,"journal":{"name":"International Journal of Medical Reviews and Case Reports","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Unsafe injection practices and its predictors in Government health care facilities of Central India.\",\"authors\":\"Aditya Thakur, M. Toppo, D. Pal\",\"doi\":\"10.5455/ijmrcr.172-1669868821\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction- Irrational and unsafe injection practices are Insidious in developing countries harming the patient and alluring risks to the health care workers. Poor injection practices, including injection overuse and unsafe practices have been reported in many developing and transitional countries Objective - To determine the proportion and predictors of unsafe injections practices in government health facilities. Material and method - It was a descriptive cross-sectional study done in duration of 6 months A sample of 280 was calculated and 83 injection units of 11 government health care facilities were considered for the assessment. Generation of descriptive Statistics was done. Chi-square test and multivariate logistic regression analysis was used to identify potential risk factor of unsafe injection practices. Result- 45 % of the injection practices out of total 280 observed injection practice in all the 11 facilities selected in study is found to be unsafe. Primary health care facilities were 2.13 times more likely to exhibit unsafe injection practice while secondary health care facilities were 1.45 times more prone to unsafe injection practice as compare to tertiary health care facilities. Conclusion- High frequency of noncompliance to best injection safety practices are widespread in the government facilities. This Situation is even worse in the primary health center and community health center.\",\"PeriodicalId\":13694,\"journal\":{\"name\":\"International Journal of Medical Reviews and Case Reports\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Medical Reviews and Case Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5455/ijmrcr.172-1669868821\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Reviews and Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5455/ijmrcr.172-1669868821","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

引言-在发展中国家,不合理和不安全的注射做法是潜在的,对患者造成伤害,并给卫生保健工作者带来风险。许多发展中国家和转型国家都报告了不良注射做法,包括注射过度使用和不安全做法。目标-确定政府卫生设施中不安全注射做法的比例和预测因素。材料和方法——这是一项为期6个月的描述性横断面研究,计算了280个样本,并考虑了11个政府卫生保健设施的83个注射单位进行评估。生成描述性统计数据。采用卡方检验和多因素logistic回归分析确定不安全注射操作的潜在危险因素。结果-在研究中选择的所有11个设施中观察到的280个注射操作中,有45%的注射操作被发现是不安全的。初级卫生保健设施出现不安全注射做法的可能性是三级卫生保健设施的2.13倍,而二级卫生保健设施出现不安全注射做法的可能性是三级卫生保健设施的1.45倍。结论:在政府设施中,不遵守最佳注射安全规范的频率很高。这种情况在初级保健中心和社区保健中心更为严重。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Unsafe injection practices and its predictors in Government health care facilities of Central India.
Introduction- Irrational and unsafe injection practices are Insidious in developing countries harming the patient and alluring risks to the health care workers. Poor injection practices, including injection overuse and unsafe practices have been reported in many developing and transitional countries Objective - To determine the proportion and predictors of unsafe injections practices in government health facilities. Material and method - It was a descriptive cross-sectional study done in duration of 6 months A sample of 280 was calculated and 83 injection units of 11 government health care facilities were considered for the assessment. Generation of descriptive Statistics was done. Chi-square test and multivariate logistic regression analysis was used to identify potential risk factor of unsafe injection practices. Result- 45 % of the injection practices out of total 280 observed injection practice in all the 11 facilities selected in study is found to be unsafe. Primary health care facilities were 2.13 times more likely to exhibit unsafe injection practice while secondary health care facilities were 1.45 times more prone to unsafe injection practice as compare to tertiary health care facilities. Conclusion- High frequency of noncompliance to best injection safety practices are widespread in the government facilities. This Situation is even worse in the primary health center and community health center.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Vaccine for HIV Medicinal Common Seed-Acorus Calamus A Rare Case of Placental Site Trophoblastic Tumor Post-Traumatic Feelings of Vulnerability, Psychological Disability, And Connection to Others in Victims of the 2016 Seka Train Derailment in Cameroon Multiple Polycystic Organs in A Middle Age Female: A Rare Case of More Than Ten Years Without Surgical Intervention
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1