{"title":"重铸对镍铬合金生物相容性的影响。","authors":"Chang-yuan Zhang, Hui Cheng, Dong Lin, Ming Zheng, M. Ozcan, Wei Zhao, Hao Yu","doi":"10.5167/UZH-75647","DOIUrl":null,"url":null,"abstract":"OBJECTIVE\nTo evaluate the effects of recasting on the biocompatibility of a commercially available Ni-Cr alloy.\n\n\nMETHODS\nThe alloy tested was cast and subsequently recast four more times. For each cast condition, 24 disk shaped specimens were fabricated (5 mm in diameter, 0.5 mm in thickness). All the recasting was performed without adding new alloy. After the first cast and following each recast, the surface composition and microstructure of the alloy were determined using an X-ray fluorescence spectrometer and optical microscope, respectively. The in vitro cytotoxicity and in vivo mucous irritation potential of the cast and recast Ni-Cr alloy were investigated. The results were statistically analysed at the significance level of 0.05.\n\n\nRESULTS\nRecasting neither yielded to cytotoxicity or to changes in the surface composition of the Ni-Cr alloy tested. However, an increase in impurities and porosity of the surface structure was observed with recasting. Also, the segregation of the impurities to grain boundaries was evident after multiple castings. After the fourth recast, the alloys showed significantly greater mucosal irritation than the control.\n\n\nCONCLUSION\nAfter fourth recast, the alloy of this type may contribute to mucosal inflammation. Furthermore, there is a need for diverse methods addressing different biological endpoints for the evaluation of dental alloys.","PeriodicalId":22405,"journal":{"name":"The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association","volume":"78 1","pages":"105-13"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Effects of recasting on the biocompatibility of a Ni-Cr alloy.\",\"authors\":\"Chang-yuan Zhang, Hui Cheng, Dong Lin, Ming Zheng, M. Ozcan, Wei Zhao, Hao Yu\",\"doi\":\"10.5167/UZH-75647\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVE\\nTo evaluate the effects of recasting on the biocompatibility of a commercially available Ni-Cr alloy.\\n\\n\\nMETHODS\\nThe alloy tested was cast and subsequently recast four more times. For each cast condition, 24 disk shaped specimens were fabricated (5 mm in diameter, 0.5 mm in thickness). All the recasting was performed without adding new alloy. After the first cast and following each recast, the surface composition and microstructure of the alloy were determined using an X-ray fluorescence spectrometer and optical microscope, respectively. The in vitro cytotoxicity and in vivo mucous irritation potential of the cast and recast Ni-Cr alloy were investigated. The results were statistically analysed at the significance level of 0.05.\\n\\n\\nRESULTS\\nRecasting neither yielded to cytotoxicity or to changes in the surface composition of the Ni-Cr alloy tested. However, an increase in impurities and porosity of the surface structure was observed with recasting. Also, the segregation of the impurities to grain boundaries was evident after multiple castings. After the fourth recast, the alloys showed significantly greater mucosal irritation than the control.\\n\\n\\nCONCLUSION\\nAfter fourth recast, the alloy of this type may contribute to mucosal inflammation. Furthermore, there is a need for diverse methods addressing different biological endpoints for the evaluation of dental alloys.\",\"PeriodicalId\":22405,\"journal\":{\"name\":\"The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association\",\"volume\":\"78 1\",\"pages\":\"105-13\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5167/UZH-75647\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Chinese journal of dental research : the official journal of the Scientific Section of the Chinese Stomatological Association","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5167/UZH-75647","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

目的评价重铸对市售镍铬合金生物相容性的影响。方法对试验合金进行铸造,再进行4次重铸。在每种铸造条件下,制作24个圆盘形试样(直径5mm,厚度0.5 mm)。所有的重铸都是在不添加新合金的情况下进行的。在第一次铸造和每次重铸后,分别使用x射线荧光光谱仪和光学显微镜测定合金的表面成分和显微组织。研究了铸态和重铸态镍铬合金的体外细胞毒性和体内粘膜刺激电位。对结果进行统计学分析,显著性水平为0.05。结果重铸对镍铬合金的细胞毒性和表面成分均无影响。然而,在重铸过程中,观察到杂质和表面结构孔隙率的增加。多次铸造后,杂质向晶界偏析明显。在第四次重铸后,合金表现出比对照组更大的粘膜刺激。结论该类型合金在四次重铸后可能引起粘膜炎症。此外,需要不同的方法来处理不同的生物终点,以评估牙科合金。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effects of recasting on the biocompatibility of a Ni-Cr alloy.
OBJECTIVE To evaluate the effects of recasting on the biocompatibility of a commercially available Ni-Cr alloy. METHODS The alloy tested was cast and subsequently recast four more times. For each cast condition, 24 disk shaped specimens were fabricated (5 mm in diameter, 0.5 mm in thickness). All the recasting was performed without adding new alloy. After the first cast and following each recast, the surface composition and microstructure of the alloy were determined using an X-ray fluorescence spectrometer and optical microscope, respectively. The in vitro cytotoxicity and in vivo mucous irritation potential of the cast and recast Ni-Cr alloy were investigated. The results were statistically analysed at the significance level of 0.05. RESULTS Recasting neither yielded to cytotoxicity or to changes in the surface composition of the Ni-Cr alloy tested. However, an increase in impurities and porosity of the surface structure was observed with recasting. Also, the segregation of the impurities to grain boundaries was evident after multiple castings. After the fourth recast, the alloys showed significantly greater mucosal irritation than the control. CONCLUSION After fourth recast, the alloy of this type may contribute to mucosal inflammation. Furthermore, there is a need for diverse methods addressing different biological endpoints for the evaluation of dental alloys.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Maxillary Sinus Floor Augmentation with Two Different Inorganic Bovine Bone Grafts: an Experimental Study in Rabbits. Relationship between Chewing Sugar-free Gum and Dental Caries Status in China. Structure and Composition of Candidate Phyla Radiation in Supragingival Plaque of Caries Patients. Age Estimation using Panoramic Radiographs by Transfer Learning. Polyetheretherketone Framework for Implant-supported Full-arch Fixed Dental Prostheses in a Periodontitis Patient with a 6-year Follow-up: a Case Report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1