大视场编码孔径推扫康普顿散射成像研究进展

Y. Liu, X. Xiao, Z. Zhang, W. Zhou, X. Wang, L. Wei
{"title":"大视场编码孔径推扫康普顿散射成像研究进展","authors":"Y. Liu, X. Xiao, Z. Zhang, W. Zhou, X. Wang, L. Wei","doi":"10.1109/NSS/MIC42677.2020.9507955","DOIUrl":null,"url":null,"abstract":"Compton scatter imaging (CSI) is a useful nondestructive testing technique because of its flexible detection layout and high sensitivity to low-Z but high-density materials such as organics. However, previous CSI methods are limited by their low use of X-rays. Recently, we have devised a novel method called coded aperture push-broom CSI (CAPCSI) to improve the use of X-rays. In this work, we will present our progress on large field-of-view CAPCSI. A fan-beam of X-rays scans objects line-by-line and then the X-rays are scattered backward to two linear array detectors. Each detector consists of 144 scintillators, 96 Silicon photo-multipliers, and a 32-channel readout circuit array. In front of the two detectors, a mask and an anti-mask are placed individually to filter the backscattered X-rays. The coding sequences of the mask and the anti-mask are just opposite so that two complementary images could be recorded simultaneously. After averaging the two images, we finally obtain a better image for low-dose imaging.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"42 1","pages":"1-2"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Progress on large field-of-view coded aperture push-broom Compton scatter imaging\",\"authors\":\"Y. Liu, X. Xiao, Z. Zhang, W. Zhou, X. Wang, L. Wei\",\"doi\":\"10.1109/NSS/MIC42677.2020.9507955\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Compton scatter imaging (CSI) is a useful nondestructive testing technique because of its flexible detection layout and high sensitivity to low-Z but high-density materials such as organics. However, previous CSI methods are limited by their low use of X-rays. Recently, we have devised a novel method called coded aperture push-broom CSI (CAPCSI) to improve the use of X-rays. In this work, we will present our progress on large field-of-view CAPCSI. A fan-beam of X-rays scans objects line-by-line and then the X-rays are scattered backward to two linear array detectors. Each detector consists of 144 scintillators, 96 Silicon photo-multipliers, and a 32-channel readout circuit array. In front of the two detectors, a mask and an anti-mask are placed individually to filter the backscattered X-rays. The coding sequences of the mask and the anti-mask are just opposite so that two complementary images could be recorded simultaneously. After averaging the two images, we finally obtain a better image for low-dose imaging.\",\"PeriodicalId\":6760,\"journal\":{\"name\":\"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"volume\":\"42 1\",\"pages\":\"1-2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSS/MIC42677.2020.9507955\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSS/MIC42677.2020.9507955","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

康普顿散射成像(CSI)由于其灵活的检测布局和对低z高密度材料(如有机物)的高灵敏度而成为一种有用的无损检测技术。然而,以前的CSI方法受到x射线使用较少的限制。最近,我们设计了一种新的方法,称为编码孔径推帚CSI (CAPCSI),以提高x射线的使用。在这项工作中,我们将介绍我们在大视场CAPCSI方面的进展。一束扇形x射线逐行扫描物体,然后将x射线散射到两个线性阵列探测器上。每个探测器由144个闪烁体、96个硅光倍增器和一个32通道读出电路阵列组成。在两个探测器的前面,分别放置一个掩膜和一个反掩膜来过滤反向散射的x射线。掩码与反掩码的编码序列正好相反,可以同时记录两幅互补的图像。将两幅图像平均后,最终得到较好的低剂量成像图像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Progress on large field-of-view coded aperture push-broom Compton scatter imaging
Compton scatter imaging (CSI) is a useful nondestructive testing technique because of its flexible detection layout and high sensitivity to low-Z but high-density materials such as organics. However, previous CSI methods are limited by their low use of X-rays. Recently, we have devised a novel method called coded aperture push-broom CSI (CAPCSI) to improve the use of X-rays. In this work, we will present our progress on large field-of-view CAPCSI. A fan-beam of X-rays scans objects line-by-line and then the X-rays are scattered backward to two linear array detectors. Each detector consists of 144 scintillators, 96 Silicon photo-multipliers, and a 32-channel readout circuit array. In front of the two detectors, a mask and an anti-mask are placed individually to filter the backscattered X-rays. The coding sequences of the mask and the anti-mask are just opposite so that two complementary images could be recorded simultaneously. After averaging the two images, we finally obtain a better image for low-dose imaging.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance of Dual-Ended Readout PET Detectors Based on SiPMs with Different Microcell Sizes Neural Network-based Inter-crystal Scatter Event Positioning in a PET System Design Based on 3D Position Sensitive Detectors An e-LINAC driven PGNAA system for concealed drug inspection Design of a Multi-Technology Pre-Clinical SPECT System Comprehensive Simulation and Design of 3D Silicon Sensors for Enhanced Timing Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1