微处理器表面等离子共振生物分析仪的改进质心算法

Jiandong Hu, Xiangyang Zhao
{"title":"微处理器表面等离子共振生物分析仪的改进质心算法","authors":"Jiandong Hu, Xiangyang Zhao","doi":"10.1109/SOPO.2009.5230137","DOIUrl":null,"url":null,"abstract":"We present an improved centroid algorithm designed for an economical, high-performance biomolecular interaction analyzer, which is based on the use of TSPR1k23 biosensors and composed of a microflow cell, a thermoelectric cooler (TEC), a clamp, a touch-screen monitor, three microprocessors and a photoelectronic conversion device. The proposed algorithm can be applied to asymmetric surfac plasmon resonance (SPR) curves often obtained by a gold-based SPR biochemical analyzer and evaluated by the numerical calculations. The validity and efficiency of the algorithm were demonstrated by a comparison of the numerical calculation results with the experimental results obtained by using the SPR biochemical analyzer to measure the ethanol solutions with five concentrations of 10, 20, 30, 40, 50 wt.%. The sensitivity of the SPR biochemical analyzer was fairly enhanced by the improved centroid algorithm that we argued in this work even without the assistance of a laptop computer. In comparsion with the first-order centroid algorithm, the experimental results further showed that the errors of measurement could be reduced when such an improved centroid algorithm was used.","PeriodicalId":6416,"journal":{"name":"2009 Symposium on Photonics and Optoelectronics","volume":"4 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2009-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"An Improved Centroid Algorithm for a Surface Plasmon Resonance Bioanalyzer Using Microprocessors\",\"authors\":\"Jiandong Hu, Xiangyang Zhao\",\"doi\":\"10.1109/SOPO.2009.5230137\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We present an improved centroid algorithm designed for an economical, high-performance biomolecular interaction analyzer, which is based on the use of TSPR1k23 biosensors and composed of a microflow cell, a thermoelectric cooler (TEC), a clamp, a touch-screen monitor, three microprocessors and a photoelectronic conversion device. The proposed algorithm can be applied to asymmetric surfac plasmon resonance (SPR) curves often obtained by a gold-based SPR biochemical analyzer and evaluated by the numerical calculations. The validity and efficiency of the algorithm were demonstrated by a comparison of the numerical calculation results with the experimental results obtained by using the SPR biochemical analyzer to measure the ethanol solutions with five concentrations of 10, 20, 30, 40, 50 wt.%. The sensitivity of the SPR biochemical analyzer was fairly enhanced by the improved centroid algorithm that we argued in this work even without the assistance of a laptop computer. In comparsion with the first-order centroid algorithm, the experimental results further showed that the errors of measurement could be reduced when such an improved centroid algorithm was used.\",\"PeriodicalId\":6416,\"journal\":{\"name\":\"2009 Symposium on Photonics and Optoelectronics\",\"volume\":\"4 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Symposium on Photonics and Optoelectronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SOPO.2009.5230137\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Symposium on Photonics and Optoelectronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SOPO.2009.5230137","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

我们提出了一种改进的质心算法,设计用于经济,高性能的生物分子相互作用分析仪,该分析仪基于使用TSPR1k23生物传感器,由微流池,热电冷却器(TEC),钳,触摸屏显示器,三个微处理器和光电转换装置组成。该算法可应用于非对称表面等离子体共振(SPR)曲线,并可通过数值计算对其进行评价。用SPR生化分析仪对10、20、30、40、50 wt.% 5种浓度的乙醇溶液进行测量,并将数值计算结果与实验结果进行比较,验证了该算法的有效性和有效性。在没有笔记本电脑的情况下,SPR生化分析仪的灵敏度通过改进的质心算法得到了相当的提高。与一阶质心算法相比,实验结果进一步表明,采用改进的质心算法可以减小测量误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An Improved Centroid Algorithm for a Surface Plasmon Resonance Bioanalyzer Using Microprocessors
We present an improved centroid algorithm designed for an economical, high-performance biomolecular interaction analyzer, which is based on the use of TSPR1k23 biosensors and composed of a microflow cell, a thermoelectric cooler (TEC), a clamp, a touch-screen monitor, three microprocessors and a photoelectronic conversion device. The proposed algorithm can be applied to asymmetric surfac plasmon resonance (SPR) curves often obtained by a gold-based SPR biochemical analyzer and evaluated by the numerical calculations. The validity and efficiency of the algorithm were demonstrated by a comparison of the numerical calculation results with the experimental results obtained by using the SPR biochemical analyzer to measure the ethanol solutions with five concentrations of 10, 20, 30, 40, 50 wt.%. The sensitivity of the SPR biochemical analyzer was fairly enhanced by the improved centroid algorithm that we argued in this work even without the assistance of a laptop computer. In comparsion with the first-order centroid algorithm, the experimental results further showed that the errors of measurement could be reduced when such an improved centroid algorithm was used.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Low-Cost Delay-Constrained Routing and Wavelength Assignment Algorithm in WDM Networks with Sparse Wavelength Conversions Linear Birefringence and Linear Dichroism Coupled Optical Anisotropy of Magnetic Fluids by External Magnetic Fields Various Polygonal Semiconductor Lasers Directional Couplers Using V-Groove Plasma Waveguides An Improved Wavelength Detection System for Fiber Grating Sensors Based on LabVIEW
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1