{"title":"硅树脂处理烧结玻璃板的拒水性","authors":"M. Barrington, D. Fleet, R. R. McLaughlin","doi":"10.1139/cjr50f-042","DOIUrl":null,"url":null,"abstract":"The hydrostatic pressures that silicone-coated sintered glass plates will withstand before permitting the passage of water are recorded, and a rough constancy in the product of rupturing pressure and porosity is indicated. Application as check-valves to pass gases but not water is suggested.","PeriodicalId":9392,"journal":{"name":"Canadian journal of research","volume":"1 1","pages":"461-463"},"PeriodicalIF":0.0000,"publicationDate":"1950-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"THE WATER-REPELLENCY OF SILICONE-TREATED SINTERED GLASS PLATES\",\"authors\":\"M. Barrington, D. Fleet, R. R. McLaughlin\",\"doi\":\"10.1139/cjr50f-042\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The hydrostatic pressures that silicone-coated sintered glass plates will withstand before permitting the passage of water are recorded, and a rough constancy in the product of rupturing pressure and porosity is indicated. Application as check-valves to pass gases but not water is suggested.\",\"PeriodicalId\":9392,\"journal\":{\"name\":\"Canadian journal of research\",\"volume\":\"1 1\",\"pages\":\"461-463\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1950-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canadian journal of research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1139/cjr50f-042\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian journal of research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1139/cjr50f-042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
THE WATER-REPELLENCY OF SILICONE-TREATED SINTERED GLASS PLATES
The hydrostatic pressures that silicone-coated sintered glass plates will withstand before permitting the passage of water are recorded, and a rough constancy in the product of rupturing pressure and porosity is indicated. Application as check-valves to pass gases but not water is suggested.