具有高频隔离的双降压交流-交流转换器

Ashraf Ali Khan, Honnyong Cha, H. Ahmed, Heung-Geun Kim
{"title":"具有高频隔离的双降压交流-交流转换器","authors":"Ashraf Ali Khan, Honnyong Cha, H. Ahmed, Heung-Geun Kim","doi":"10.1109/IPEMC.2016.7512459","DOIUrl":null,"url":null,"abstract":"In this paper, double step-down isolated ac-ac converters are proposed. The proposed converters have double step-down function and provides electrical isolation using high frequency transformer. The proposed converters avoid the saturation of transformer by adding a capacitor. In addition, the voltage stress of three bidirectional switches at the primary side of transformer is half of input voltage. The voltage across the primary winding of transformer is also half of input voltage, therefore the transformer of the proposed converters can be designed with smaller size, low leakage inductance and less isolation requirements. The proposed converters have double step-down function with high frequency galvanic isolation, and have low voltage stress across the switches and transformer, therefore they can be good candidates for solid state transformer.","PeriodicalId":6857,"journal":{"name":"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)","volume":"6 1","pages":"1200-1205"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Double step-down AC-AC converters with high frequency isolation\",\"authors\":\"Ashraf Ali Khan, Honnyong Cha, H. Ahmed, Heung-Geun Kim\",\"doi\":\"10.1109/IPEMC.2016.7512459\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, double step-down isolated ac-ac converters are proposed. The proposed converters have double step-down function and provides electrical isolation using high frequency transformer. The proposed converters avoid the saturation of transformer by adding a capacitor. In addition, the voltage stress of three bidirectional switches at the primary side of transformer is half of input voltage. The voltage across the primary winding of transformer is also half of input voltage, therefore the transformer of the proposed converters can be designed with smaller size, low leakage inductance and less isolation requirements. The proposed converters have double step-down function with high frequency galvanic isolation, and have low voltage stress across the switches and transformer, therefore they can be good candidates for solid state transformer.\",\"PeriodicalId\":6857,\"journal\":{\"name\":\"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)\",\"volume\":\"6 1\",\"pages\":\"1200-1205\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPEMC.2016.7512459\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 8th International Power Electronics and Motion Control Conference (IPEMC-ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEMC.2016.7512459","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种双降压隔离型交流-交流变换器。所提出的变换器具有双降压功能,并使用高频变压器提供电气隔离。该变换器通过增加电容器来避免变压器饱和。另外,变压器一次侧三个双向开关的电压应力为输入电压的一半。变压器初级绕组的电压也是输入电压的一半,因此所提出的变换器的变压器可以设计成更小的尺寸,低漏感和更少的隔离要求。所提出的变换器具有双降压功能,具有高频电流隔离,并且开关和变压器之间的电压应力低,因此可以作为固态变压器的良好候选者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Double step-down AC-AC converters with high frequency isolation
In this paper, double step-down isolated ac-ac converters are proposed. The proposed converters have double step-down function and provides electrical isolation using high frequency transformer. The proposed converters avoid the saturation of transformer by adding a capacitor. In addition, the voltage stress of three bidirectional switches at the primary side of transformer is half of input voltage. The voltage across the primary winding of transformer is also half of input voltage, therefore the transformer of the proposed converters can be designed with smaller size, low leakage inductance and less isolation requirements. The proposed converters have double step-down function with high frequency galvanic isolation, and have low voltage stress across the switches and transformer, therefore they can be good candidates for solid state transformer.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Smart Transformer reliability and efficiency through modularity Passive regenerative snubber cell applied to isolated DCM SEPIC converter Optimal power scheduling for an islanded hybrid microgrid Analysis of power losses in power MOSFET based stacked polyphase bridges converters Performance evaluation of a non-isolated bidirectional three-port power converter for energy storage applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1