基于新型三维计算机断层扫描方法的预制牙冠耐磨性比较。

IF 1.5 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Pediatric dentistry Pub Date : 2023-01-15
Julia Kai-Chin Peng, Jung-Wei Chen, Roberto Savignano, Brian Goodacre
{"title":"基于新型三维计算机断层扫描方法的预制牙冠耐磨性比较。","authors":"Julia Kai-Chin Peng,&nbsp;Jung-Wei Chen,&nbsp;Roberto Savignano,&nbsp;Brian Goodacre","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to compare the wear resistance of stainless steel crowns, (SSCs), zirconia crowns (ZRCs), and nanohybrid crowns (NHCs) using a 3D tomography method.</p><p><strong>Methods: </strong>Prefabricated SSCs, ZRCs, and NHCs (n equals 80) were worn for 400,000 cycles, equivalent to three years of simulated clinical wear, at 50 N and 1.2 Hz using the Leinfelder-Suzuki wear tester. Wear volume, maximum wear depth, and wear surface area were computed using a 3D superimposition method and 2D imaging software. Data were statistically analyzed using one-way analysis of variance with the least significant difference post hoc test (P<0.05).</p><p><strong>Results: </strong>After a wear simulation of three years, NHCs had a 45 percent failure rate; NHCs also had the greatest wear volume loss (0.71 mm³), maximum wear depth (0.22 mm), and wear surface area (4.45 mm²). SSCs (0.23 mm³ , 0.12 mm, 2.63 mm²) and ZRCs (0.03 mm³ , 0.08 mm, 0.20 mm ²) had less wear volume, area, and depth (P<0.001). ZRCs were the most abrasive to their antagonists (P<0.001). The NHC (against SSC wearing group) had the greatest total wear facet surface area (4.43 mm²).</p><p><strong>Conclusions: </strong>Stainless steel crowns and zirconia crowns were the most wear-resistant materials. Based on these laboratory findings, in the primary dentition, nanohybrid crowns are not recommended as long-term restorations beyond 12 months (P=0.001).</p>","PeriodicalId":19863,"journal":{"name":"Pediatric dentistry","volume":"45 1","pages":"52-59"},"PeriodicalIF":1.5000,"publicationDate":"2023-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Wear Resistance Comparison of Prefabricated Primary Crowns Using a Novel 3D Computed Tomography Method.\",\"authors\":\"Julia Kai-Chin Peng,&nbsp;Jung-Wei Chen,&nbsp;Roberto Savignano,&nbsp;Brian Goodacre\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of this study was to compare the wear resistance of stainless steel crowns, (SSCs), zirconia crowns (ZRCs), and nanohybrid crowns (NHCs) using a 3D tomography method.</p><p><strong>Methods: </strong>Prefabricated SSCs, ZRCs, and NHCs (n equals 80) were worn for 400,000 cycles, equivalent to three years of simulated clinical wear, at 50 N and 1.2 Hz using the Leinfelder-Suzuki wear tester. Wear volume, maximum wear depth, and wear surface area were computed using a 3D superimposition method and 2D imaging software. Data were statistically analyzed using one-way analysis of variance with the least significant difference post hoc test (P<0.05).</p><p><strong>Results: </strong>After a wear simulation of three years, NHCs had a 45 percent failure rate; NHCs also had the greatest wear volume loss (0.71 mm³), maximum wear depth (0.22 mm), and wear surface area (4.45 mm²). SSCs (0.23 mm³ , 0.12 mm, 2.63 mm²) and ZRCs (0.03 mm³ , 0.08 mm, 0.20 mm ²) had less wear volume, area, and depth (P<0.001). ZRCs were the most abrasive to their antagonists (P<0.001). The NHC (against SSC wearing group) had the greatest total wear facet surface area (4.43 mm²).</p><p><strong>Conclusions: </strong>Stainless steel crowns and zirconia crowns were the most wear-resistant materials. Based on these laboratory findings, in the primary dentition, nanohybrid crowns are not recommended as long-term restorations beyond 12 months (P=0.001).</p>\",\"PeriodicalId\":19863,\"journal\":{\"name\":\"Pediatric dentistry\",\"volume\":\"45 1\",\"pages\":\"52-59\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-01-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pediatric dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric dentistry","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:采用三维断层扫描方法比较不锈钢冠(ssc)、氧化锆冠(zrc)和纳米复合冠(NHCs)的耐磨性。方法:使用leinfeld - suzuki磨损试验机,在50 n和1.2 Hz下,使用预制ssc、zrc和NHCs (n = 80)进行40万次循环磨损,相当于3年的模拟临床磨损。使用三维叠加法和二维成像软件计算磨损体积、最大磨损深度和磨损表面积。使用单向方差分析对数据进行统计分析,采用最小显著差异事后检验(结果:经过三年的磨损模拟,NHCs的故障率为45%;NHCs的磨损体积损失最大(0.71 mm³),磨损深度最大(0.22 mm),磨损表面积最大(4.45 mm²)。ssc (0.23 mm³,0.12 mm, 2.63 mm²)和zrc (0.03 mm³,0.08 mm, 0.20 mm²)的磨损体积、面积和深度较小(结论:不锈钢冠和氧化锆冠最耐磨。基于这些实验室结果,在初级牙列中,纳米杂交冠不推荐作为超过12个月的长期修复(P=0.001)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Wear Resistance Comparison of Prefabricated Primary Crowns Using a Novel 3D Computed Tomography Method.

Purpose: The purpose of this study was to compare the wear resistance of stainless steel crowns, (SSCs), zirconia crowns (ZRCs), and nanohybrid crowns (NHCs) using a 3D tomography method.

Methods: Prefabricated SSCs, ZRCs, and NHCs (n equals 80) were worn for 400,000 cycles, equivalent to three years of simulated clinical wear, at 50 N and 1.2 Hz using the Leinfelder-Suzuki wear tester. Wear volume, maximum wear depth, and wear surface area were computed using a 3D superimposition method and 2D imaging software. Data were statistically analyzed using one-way analysis of variance with the least significant difference post hoc test (P<0.05).

Results: After a wear simulation of three years, NHCs had a 45 percent failure rate; NHCs also had the greatest wear volume loss (0.71 mm³), maximum wear depth (0.22 mm), and wear surface area (4.45 mm²). SSCs (0.23 mm³ , 0.12 mm, 2.63 mm²) and ZRCs (0.03 mm³ , 0.08 mm, 0.20 mm ²) had less wear volume, area, and depth (P<0.001). ZRCs were the most abrasive to their antagonists (P<0.001). The NHC (against SSC wearing group) had the greatest total wear facet surface area (4.43 mm²).

Conclusions: Stainless steel crowns and zirconia crowns were the most wear-resistant materials. Based on these laboratory findings, in the primary dentition, nanohybrid crowns are not recommended as long-term restorations beyond 12 months (P=0.001).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pediatric dentistry
Pediatric dentistry DENTISTRY, ORAL SURGERY & MEDICINEPEDIATRI-PEDIATRICS
CiteScore
1.20
自引率
6.20%
发文量
74
审稿时长
>12 weeks
期刊介绍: Pediatric Dentistry is the official publication of the American Academy of Pediatric Dentistry, the American Board of Pediatric Dentistry and the College of Diplomates of the American Board of Pediatric Dentistry. It is published bi-monthly and is internationally recognized as the leading journal in the area of pediatric dentistry. The journal promotes the practice, education and research specifically related to the specialty of pediatric dentistry. This peer-reviewed journal features scientific articles, case reports and abstracts of current pediatric dental research.
期刊最新文献
A Randomized Clinical Trial of Short Fiber Reinforced Composite and Glass Hybrid Restoration for Molars Affected by Molar Hypomineralization. Oral Health in the Down Syndrome Population: Parental Perceptions on Dental Care in the United States. Early Introduction of Total Sugar Foods and Early Childhood Caries. Articaine Infiltration Versus Lidocaine Inferior Alveolar Nerve Block for Primary Mandibular Molars: A Double-blind Randomized Controlled Clinical Trial. Pre-, Peri-, and Postnatal Risk for the Development of Enamel Defects in Permanent Dentition: A Birth Cohort in Southern Brazil.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1