Francisco Javier Hernández Guzmán, J. Cleves-Leguízamo, Eliecer David Diaz Almanza
{"title":"哥伦比亚自动农业气象站测量的土壤湿度变量质量控制方法建议","authors":"Francisco Javier Hernández Guzmán, J. Cleves-Leguízamo, Eliecer David Diaz Almanza","doi":"10.15446/rfnam.v75n3.99145","DOIUrl":null,"url":null,"abstract":"Methodological criteria for data quality control with geophysical range and spectrum consistency were evaluated, establishing flags and quality indicators for soil moisture data records, in a range of depths between 10, 30, and 50 cm, from automatic agro-meteorological stations located in the most important agricultural regions of Colombia. Data for analysis were collected from 105 stations of the IDEAM network, in an observation window from 2001-2020. The results showed that 40.3% of the soil moisture data were of good quality, 12.9% were questionable due to spectrum flags, 14.3% were questionable due to geophysical range and 32% were erroneous because the values were not possible and/or missing. The depth closest to the surface had the highest number of quality flags, suggesting that the soil layer has the highest error detection rate associated with soil moisture condition recording; the most common quality flag was C02: “Soil moisture >60% & ≤100%”, detected in 93% of the sensors, and the second most frequent flag was C01: “Soil moisture ≥0% & <3%”. It was concluded that the proposed methodology provides highly satisfactory results in the detection of anomalous soil moisture records, in order to make adjustments to the environmental conditions of Colombia.","PeriodicalId":37747,"journal":{"name":"Revista Facultad Nacional de Agronomia Medellin","volume":"73 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A methodological proposal for quality control of the soil moisture variable, measured in Colombian automatic agrometeorological stations\",\"authors\":\"Francisco Javier Hernández Guzmán, J. Cleves-Leguízamo, Eliecer David Diaz Almanza\",\"doi\":\"10.15446/rfnam.v75n3.99145\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Methodological criteria for data quality control with geophysical range and spectrum consistency were evaluated, establishing flags and quality indicators for soil moisture data records, in a range of depths between 10, 30, and 50 cm, from automatic agro-meteorological stations located in the most important agricultural regions of Colombia. Data for analysis were collected from 105 stations of the IDEAM network, in an observation window from 2001-2020. The results showed that 40.3% of the soil moisture data were of good quality, 12.9% were questionable due to spectrum flags, 14.3% were questionable due to geophysical range and 32% were erroneous because the values were not possible and/or missing. The depth closest to the surface had the highest number of quality flags, suggesting that the soil layer has the highest error detection rate associated with soil moisture condition recording; the most common quality flag was C02: “Soil moisture >60% & ≤100%”, detected in 93% of the sensors, and the second most frequent flag was C01: “Soil moisture ≥0% & <3%”. It was concluded that the proposed methodology provides highly satisfactory results in the detection of anomalous soil moisture records, in order to make adjustments to the environmental conditions of Colombia.\",\"PeriodicalId\":37747,\"journal\":{\"name\":\"Revista Facultad Nacional de Agronomia Medellin\",\"volume\":\"73 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Facultad Nacional de Agronomia Medellin\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15446/rfnam.v75n3.99145\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Agricultural and Biological Sciences\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Facultad Nacional de Agronomia Medellin","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15446/rfnam.v75n3.99145","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Agricultural and Biological Sciences","Score":null,"Total":0}
A methodological proposal for quality control of the soil moisture variable, measured in Colombian automatic agrometeorological stations
Methodological criteria for data quality control with geophysical range and spectrum consistency were evaluated, establishing flags and quality indicators for soil moisture data records, in a range of depths between 10, 30, and 50 cm, from automatic agro-meteorological stations located in the most important agricultural regions of Colombia. Data for analysis were collected from 105 stations of the IDEAM network, in an observation window from 2001-2020. The results showed that 40.3% of the soil moisture data were of good quality, 12.9% were questionable due to spectrum flags, 14.3% were questionable due to geophysical range and 32% were erroneous because the values were not possible and/or missing. The depth closest to the surface had the highest number of quality flags, suggesting that the soil layer has the highest error detection rate associated with soil moisture condition recording; the most common quality flag was C02: “Soil moisture >60% & ≤100%”, detected in 93% of the sensors, and the second most frequent flag was C01: “Soil moisture ≥0% & <3%”. It was concluded that the proposed methodology provides highly satisfactory results in the detection of anomalous soil moisture records, in order to make adjustments to the environmental conditions of Colombia.
期刊介绍:
La Revista Facultad Nacional de Agronomía Medellín (RFNA), de la Universidad Nacional de Colombia, Sede Medellín, Facultad de Ciencias Agrarias, es una publicación científica editada desde el año 1939, en formato impreso y digital y de acceso abierto desde la web —sin costo para autores y lectores—. Está orientada a investigadores que crean conocimiento disciplinar y multidisciplinar que articula la ciencia y la tecnología para hacer más productivo el campo a nivel empresarial y de economía campesina. La Revista tiene como objetivo divulgar resultados de investigación mediante artículos originales, inéditos y arbitrados (peer review) de carácter científico que respondan a preguntas específicas y que proporcionen sustento y pruebas a una hipótesis, en aspectos relacionados con las Ciencias Agronómicas, Producción animal, Ciencias Forestales, Ingeniería Agrícola, de Alimentos y otras afines que contribuyan a la solución de los limitantes del agro a nivel nacional, regional e internacional. La Revista recibe y publica, sin ningún costo, artículos en idioma inglés de investigación, revisión, reseñas y cartas al editor. Desde el 2017 la periodicidad de publicación es cuatrimestral, se publican tres números al año con circulación nacional e internacional, en los siguientes períodos: Enero - Abril Mayo - Agosto Septiembre - Diciembre This journal does not charge APCs or submission charges.