K. Abe, K. Hiraide, K. Ichimura, Y. Kishimoto, K. Kobayashi, M. Kobayashi, S. Moriyama, M. Nakahata, T. Norita, H. Ogawa, Katsuhiko Sato, H. Sekiya, O. Takachio, A. Takeda, S. Tasaka, M. Yamashita, B. Yang, N. Y. Kim, Y. Kim, Y. Itow, K. Kanzawa, R. Kegasa, K. Masuda, H. Takiya, K. Fushimi, G. Kanzaki, K. Martens, Yoshihiro Suzuki, B. D. Xu, R. Fujita, K. Hosokawa, K. Miuchi, N. Oka, Y. Takeuchi, Y. H. Kim, K. Lee, M. Lee, Y. Fukuda, M. Miyasaka, K. Nishijima, S. Nakamura
{"title":"xmass - 1中粒子识别对$^{124}$Xe和$^{126}$Xe上双中微子双电子捕获的改进搜索","authors":"K. Abe, K. Hiraide, K. Ichimura, Y. Kishimoto, K. Kobayashi, M. Kobayashi, S. Moriyama, M. Nakahata, T. Norita, H. Ogawa, Katsuhiko Sato, H. Sekiya, O. Takachio, A. Takeda, S. Tasaka, M. Yamashita, B. Yang, N. Y. Kim, Y. Kim, Y. Itow, K. Kanzawa, R. Kegasa, K. Masuda, H. Takiya, K. Fushimi, G. Kanzaki, K. Martens, Yoshihiro Suzuki, B. D. Xu, R. Fujita, K. Hosokawa, K. Miuchi, N. Oka, Y. Takeuchi, Y. H. Kim, K. Lee, M. Lee, Y. Fukuda, M. Miyasaka, K. Nishijima, S. Nakamura","doi":"10.1093/ptep/pty053","DOIUrl":null,"url":null,"abstract":"We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $\\gamma$-ray/$X$-ray or double electron capture signals from $\\beta$-ray background using scintillation time profiles was developed for this search. No significant signal was found when fitting the observed energy spectra with the expected signal and background. Therefore, we set the most stringent lower limits on the half-lives at $2.1 \\times 10^{22}$ and $1.9 \\times 10^{22}$ years for $^{124}$Xe and $^{126}$Xe, respectively, with 90% confidence level. These limits improve upon previously reported values by a factor of 4.5.","PeriodicalId":8464,"journal":{"name":"arXiv: Nuclear Experiment","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"Improved search for two-neutrino double electron capture on $^{124}$Xe and $^{126}$Xe using particle identification in XMASS-I\",\"authors\":\"K. Abe, K. Hiraide, K. Ichimura, Y. Kishimoto, K. Kobayashi, M. Kobayashi, S. Moriyama, M. Nakahata, T. Norita, H. Ogawa, Katsuhiko Sato, H. Sekiya, O. Takachio, A. Takeda, S. Tasaka, M. Yamashita, B. Yang, N. Y. Kim, Y. Kim, Y. Itow, K. Kanzawa, R. Kegasa, K. Masuda, H. Takiya, K. Fushimi, G. Kanzaki, K. Martens, Yoshihiro Suzuki, B. D. Xu, R. Fujita, K. Hosokawa, K. Miuchi, N. Oka, Y. Takeuchi, Y. H. Kim, K. Lee, M. Lee, Y. Fukuda, M. Miyasaka, K. Nishijima, S. Nakamura\",\"doi\":\"10.1093/ptep/pty053\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $\\\\gamma$-ray/$X$-ray or double electron capture signals from $\\\\beta$-ray background using scintillation time profiles was developed for this search. No significant signal was found when fitting the observed energy spectra with the expected signal and background. Therefore, we set the most stringent lower limits on the half-lives at $2.1 \\\\times 10^{22}$ and $1.9 \\\\times 10^{22}$ years for $^{124}$Xe and $^{126}$Xe, respectively, with 90% confidence level. These limits improve upon previously reported values by a factor of 4.5.\",\"PeriodicalId\":8464,\"journal\":{\"name\":\"arXiv: Nuclear Experiment\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"arXiv: Nuclear Experiment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/ptep/pty053\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv: Nuclear Experiment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ptep/pty053","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21
摘要
我们利用xmass - 1探测器800.0天的数据,改进了在$^{124}$ Xe和$^{126}$ Xe核上同时捕获两个$K$ -壳层电子并发射两个中微子的搜索。为此,开发了一种利用闪烁时间谱从$\beta$射线背景中区分$\gamma$ -ray/ $X$ -ray或双电子捕获信号的新方法。将观测到的能量谱与期望信号和背景拟合时,没有发现显著信号。因此,我们为$^{124}$ Xe和$^{126}$ Xe分别设定了最严格的半衰期下限$2.1 \times 10^{22}$和$1.9 \times 10^{22}$年,为90年% confidence level. These limits improve upon previously reported values by a factor of 4.5.
Improved search for two-neutrino double electron capture on $^{124}$Xe and $^{126}$Xe using particle identification in XMASS-I
We conducted an improved search for the simultaneous capture of two $K$-shell electrons on the $^{124}$Xe and $^{126}$Xe nuclei with emission of two neutrinos using 800.0 days of data from the XMASS-I detector. A novel method to discriminate $\gamma$-ray/$X$-ray or double electron capture signals from $\beta$-ray background using scintillation time profiles was developed for this search. No significant signal was found when fitting the observed energy spectra with the expected signal and background. Therefore, we set the most stringent lower limits on the half-lives at $2.1 \times 10^{22}$ and $1.9 \times 10^{22}$ years for $^{124}$Xe and $^{126}$Xe, respectively, with 90% confidence level. These limits improve upon previously reported values by a factor of 4.5.