{"title":"预测不同压力下空气的v-t特性","authors":"S. Balaji, K. Latha Maheswari, S. Usa","doi":"10.1109/ICHVE.2012.6357006","DOIUrl":null,"url":null,"abstract":"The breakdown characteristics of any given insulation is determined by its voltage-time (v-t) characteristics. The superior characteristics of compressed air will mitigate the use of SF6 gas in Medium voltage circuit breakers and indoor design gas CB. In order to analyze the performance of compressed air experiments are carried out for various pressures and waveshapes and compared for different electrode configurations. In this paper voltage-time (v-t) characteristics are extracted for different pressures ranges from 30 mbars to 4000 mbars for impulse overvoltage ranging from 0.064/50μs, 0.4/50μs and 1.2/50μs. The breakdown characteristics are compared for uniform field and non-uniform field configurations. The Parametric constants A and B are obtained using hyperbolic model. The A and B constants are predicted for pressure of 2000 mbars and are compared with the experimental data obtained and error percentage are found.","PeriodicalId":6375,"journal":{"name":"2012 International Conference on High Voltage Engineering and Application","volume":"8 1","pages":"43-46"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Prediction of v-t Characteristics of air at different pressures\",\"authors\":\"S. Balaji, K. Latha Maheswari, S. Usa\",\"doi\":\"10.1109/ICHVE.2012.6357006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The breakdown characteristics of any given insulation is determined by its voltage-time (v-t) characteristics. The superior characteristics of compressed air will mitigate the use of SF6 gas in Medium voltage circuit breakers and indoor design gas CB. In order to analyze the performance of compressed air experiments are carried out for various pressures and waveshapes and compared for different electrode configurations. In this paper voltage-time (v-t) characteristics are extracted for different pressures ranges from 30 mbars to 4000 mbars for impulse overvoltage ranging from 0.064/50μs, 0.4/50μs and 1.2/50μs. The breakdown characteristics are compared for uniform field and non-uniform field configurations. The Parametric constants A and B are obtained using hyperbolic model. The A and B constants are predicted for pressure of 2000 mbars and are compared with the experimental data obtained and error percentage are found.\",\"PeriodicalId\":6375,\"journal\":{\"name\":\"2012 International Conference on High Voltage Engineering and Application\",\"volume\":\"8 1\",\"pages\":\"43-46\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on High Voltage Engineering and Application\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE.2012.6357006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on High Voltage Engineering and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE.2012.6357006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

任何给定绝缘的击穿特性是由其电压-时间(v-t)特性决定的。压缩空气的优越特性将减少SF6气体在中压断路器和室内设计气体CB中的使用。为了分析压缩空气的性能,在不同的压力和波形下进行了实验,并对不同的电极配置进行了比较。在脉冲过电压为0.064/50μs、0.4/50μs和1.2/50μs的情况下,提取了30 ~ 4000 mbars压力范围内的电压-时间(v-t)特性。比较了均匀场和非均匀场的击穿特性。采用双曲模型得到参数常数A和B。对压力为2000 mbar时的A、B常数进行了预测,并与实验数据进行了比较,得出了误差百分比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Prediction of v-t Characteristics of air at different pressures
The breakdown characteristics of any given insulation is determined by its voltage-time (v-t) characteristics. The superior characteristics of compressed air will mitigate the use of SF6 gas in Medium voltage circuit breakers and indoor design gas CB. In order to analyze the performance of compressed air experiments are carried out for various pressures and waveshapes and compared for different electrode configurations. In this paper voltage-time (v-t) characteristics are extracted for different pressures ranges from 30 mbars to 4000 mbars for impulse overvoltage ranging from 0.064/50μs, 0.4/50μs and 1.2/50μs. The breakdown characteristics are compared for uniform field and non-uniform field configurations. The Parametric constants A and B are obtained using hyperbolic model. The A and B constants are predicted for pressure of 2000 mbars and are compared with the experimental data obtained and error percentage are found.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effects of SiO2 particles on surface charge of epoxy nanocomposites The properties of space charge in oil-paper insulation during electrical-thermal aging A study of validation of condition monitoring method of NPPs cable through volume electrical resistivity Ice adhesion on the surface of PDMS/nano-silica hybrid super-hydrophobic coating Sensitivity study on streaming electrification of transformer liquids by using rotating disc method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1