用于热脉冲实验的空间分辨探测器

D. Hurley, G. Hardy, P. Hawker, A. Kent
{"title":"用于热脉冲实验的空间分辨探测器","authors":"D. Hurley, G. Hardy, P. Hawker, A. Kent","doi":"10.1088/0022-3735/22/10/004","DOIUrl":null,"url":null,"abstract":"A new technique for spatially resolved detection of heat pulses (phonons) at liquid-helium temperatures is described. Unlike existing phonon imaging methods, this system is not affected by the presence of magnetic fields up to at least 7 T. The method utilises a spatially extended cadmium sulphide thin film as a phonon bolometer. Small (<200 mu m) regions of the film are selectively sensitised by a microcomputer-controlled, scanned laser spot and 'reset' after data acquisition using a large ( approximately=50 mA) current pulse. Using data acquisition and analysis software, line scans of the transmitted phonon intensity as a function of propagation direction are obtained. Sample data of the phonon intensity in the (110) plane of silicon are presented.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"5 3","pages":"824-827"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"A spatially resolving detector for heat-pulse experiments\",\"authors\":\"D. Hurley, G. Hardy, P. Hawker, A. Kent\",\"doi\":\"10.1088/0022-3735/22/10/004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new technique for spatially resolved detection of heat pulses (phonons) at liquid-helium temperatures is described. Unlike existing phonon imaging methods, this system is not affected by the presence of magnetic fields up to at least 7 T. The method utilises a spatially extended cadmium sulphide thin film as a phonon bolometer. Small (<200 mu m) regions of the film are selectively sensitised by a microcomputer-controlled, scanned laser spot and 'reset' after data acquisition using a large ( approximately=50 mA) current pulse. Using data acquisition and analysis software, line scans of the transmitted phonon intensity as a function of propagation direction are obtained. Sample data of the phonon intensity in the (110) plane of silicon are presented.\",\"PeriodicalId\":16791,\"journal\":{\"name\":\"Journal of Physics E: Scientific Instruments\",\"volume\":\"5 3\",\"pages\":\"824-827\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Physics E: Scientific Instruments\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/0022-3735/22/10/004\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physics E: Scientific Instruments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0022-3735/22/10/004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

介绍了一种在液氦温度下空间分辨探测热脉冲(声子)的新技术。与现有的声子成像方法不同,该系统不受高达至少7 t的磁场存在的影响。该方法利用空间扩展的硫化镉薄膜作为声子热计。薄膜的小区域(<200 μ m)通过微型计算机控制的扫描激光光斑选择性敏化,并在使用大(约=50 mA)电流脉冲采集数据后“复位”。利用数据采集和分析软件,得到了传输声子强度随传播方向的线扫描图。给出了硅(110)平面声子强度的样本数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A spatially resolving detector for heat-pulse experiments
A new technique for spatially resolved detection of heat pulses (phonons) at liquid-helium temperatures is described. Unlike existing phonon imaging methods, this system is not affected by the presence of magnetic fields up to at least 7 T. The method utilises a spatially extended cadmium sulphide thin film as a phonon bolometer. Small (<200 mu m) regions of the film are selectively sensitised by a microcomputer-controlled, scanned laser spot and 'reset' after data acquisition using a large ( approximately=50 mA) current pulse. Using data acquisition and analysis software, line scans of the transmitted phonon intensity as a function of propagation direction are obtained. Sample data of the phonon intensity in the (110) plane of silicon are presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Apparatus for the measurement of electro-optical rotation changes in polymer solutions DESIGN NOTE: Simple oven design for highly reactive metal beam applications Ratio transformer bridge for the measurement of dielectric constant of lossy liquids Temperature resistant and vacuum tight LiF connections Accounting for the effects of gas species on piston gauge calculated area: absolute mode
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1