胫骨高位截骨中腓骨截骨对膝关节的生物力学影响:一项尸体研究。

IF 1 4区 医学 Q4 ENGINEERING, BIOMEDICAL Bio-medical materials and engineering Pub Date : 2023-01-01 DOI:10.3233/BME-221395
Osamu Tanifuji, Tomoharu Mochizuki, Yoshio Koga, Yuji Tanabe, Hiroyuki Kawashima
{"title":"胫骨高位截骨中腓骨截骨对膝关节的生物力学影响:一项尸体研究。","authors":"Osamu Tanifuji,&nbsp;Tomoharu Mochizuki,&nbsp;Yoshio Koga,&nbsp;Yuji Tanabe,&nbsp;Hiroyuki Kawashima","doi":"10.3233/BME-221395","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Closed-wedge high tibial osteotomy (CWHTO) with a fibular osteotomy (FO) causes medial joint space widening in the knee. However, the effect of FO on the joint space width remains unclear.</p><p><strong>Objective: </strong>This study aimed to examine the effect of FO on the knee in HTO.</p><p><strong>Methods: </strong>A compression load test was performed on two amputated human limbs under four conditions: (1) normal (without any osteotomy), (2) open-wedge HTO (OWHTO), (3) OWHTO with FO, and (4) CWHTO. The contact area of the femoral and tibial cartilages and the medial and lateral joint space widths in each condition were evaluated using a motion capture system with computed tomography (CT) and magnetic resonance imaging (MRI) data.</p><p><strong>Results: </strong>The contact area increased on the lateral side after OWHTO, which increased more on the lateral side with a concomitant decrease on the medial side in both subjects when FO was added to OWHTO. An increase in the medial joint space width and a decrease on the lateral side were seen in both OWHTO with FO and CWHTO.</p><p><strong>Conclusions: </strong>The contact area and joint space widths are affected by the FO, and the effect is more pronounced than the way of HTO (OWHTO or CWHTO).</p>","PeriodicalId":9109,"journal":{"name":"Bio-medical materials and engineering","volume":"34 2","pages":"123-131"},"PeriodicalIF":1.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Biomechanical effect of fibular osteotomy on the knee joint in high tibial osteotomy: A cadaveric study.\",\"authors\":\"Osamu Tanifuji,&nbsp;Tomoharu Mochizuki,&nbsp;Yoshio Koga,&nbsp;Yuji Tanabe,&nbsp;Hiroyuki Kawashima\",\"doi\":\"10.3233/BME-221395\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Closed-wedge high tibial osteotomy (CWHTO) with a fibular osteotomy (FO) causes medial joint space widening in the knee. However, the effect of FO on the joint space width remains unclear.</p><p><strong>Objective: </strong>This study aimed to examine the effect of FO on the knee in HTO.</p><p><strong>Methods: </strong>A compression load test was performed on two amputated human limbs under four conditions: (1) normal (without any osteotomy), (2) open-wedge HTO (OWHTO), (3) OWHTO with FO, and (4) CWHTO. The contact area of the femoral and tibial cartilages and the medial and lateral joint space widths in each condition were evaluated using a motion capture system with computed tomography (CT) and magnetic resonance imaging (MRI) data.</p><p><strong>Results: </strong>The contact area increased on the lateral side after OWHTO, which increased more on the lateral side with a concomitant decrease on the medial side in both subjects when FO was added to OWHTO. An increase in the medial joint space width and a decrease on the lateral side were seen in both OWHTO with FO and CWHTO.</p><p><strong>Conclusions: </strong>The contact area and joint space widths are affected by the FO, and the effect is more pronounced than the way of HTO (OWHTO or CWHTO).</p>\",\"PeriodicalId\":9109,\"journal\":{\"name\":\"Bio-medical materials and engineering\",\"volume\":\"34 2\",\"pages\":\"123-131\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bio-medical materials and engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3233/BME-221395\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bio-medical materials and engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3233/BME-221395","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 1

摘要

背景:闭合楔形高位胫骨截骨术(CWHTO)联合腓骨截骨术(FO)导致膝关节内侧关节间隙变宽。然而,FO对关节间隙宽度的影响尚不清楚。目的:本研究旨在探讨大关节损伤对膝关节的影响。方法:在4种情况下对2条人体截肢肢进行压缩负荷试验:(1)正常(未截骨),(2)开楔HTO (OWHTO), (3) OWHTO伴FO, (4) CWHTO。采用运动捕捉系统,结合计算机断层扫描(CT)和磁共振成像(MRI)数据,评估每种情况下股骨和胫骨软骨的接触面积以及内侧和外侧关节间隙宽度。结果:在OWHTO中加入FO后,两组受试者的外侧接触面积增加,外侧接触面积增加较多,内侧接触面积减少。在有FO和CWHTO的OWHTO中,内侧关节间隙宽度增加,外侧关节间隙宽度减少。结论:FO对关节接触面积和关节间隙宽度的影响明显大于HTO (OWHTO或CWHTO)方式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Biomechanical effect of fibular osteotomy on the knee joint in high tibial osteotomy: A cadaveric study.

Background: Closed-wedge high tibial osteotomy (CWHTO) with a fibular osteotomy (FO) causes medial joint space widening in the knee. However, the effect of FO on the joint space width remains unclear.

Objective: This study aimed to examine the effect of FO on the knee in HTO.

Methods: A compression load test was performed on two amputated human limbs under four conditions: (1) normal (without any osteotomy), (2) open-wedge HTO (OWHTO), (3) OWHTO with FO, and (4) CWHTO. The contact area of the femoral and tibial cartilages and the medial and lateral joint space widths in each condition were evaluated using a motion capture system with computed tomography (CT) and magnetic resonance imaging (MRI) data.

Results: The contact area increased on the lateral side after OWHTO, which increased more on the lateral side with a concomitant decrease on the medial side in both subjects when FO was added to OWHTO. An increase in the medial joint space width and a decrease on the lateral side were seen in both OWHTO with FO and CWHTO.

Conclusions: The contact area and joint space widths are affected by the FO, and the effect is more pronounced than the way of HTO (OWHTO or CWHTO).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bio-medical materials and engineering
Bio-medical materials and engineering 工程技术-材料科学:生物材料
CiteScore
1.80
自引率
0.00%
发文量
73
审稿时长
6 months
期刊介绍: The aim of Bio-Medical Materials and Engineering is to promote the welfare of humans and to help them keep healthy. This international journal is an interdisciplinary journal that publishes original research papers, review articles and brief notes on materials and engineering for biological and medical systems. Articles in this peer-reviewed journal cover a wide range of topics, including, but not limited to: Engineering as applied to improving diagnosis, therapy, and prevention of disease and injury, and better substitutes for damaged or disabled human organs; Studies of biomaterial interactions with the human body, bio-compatibility, interfacial and interaction problems; Biomechanical behavior under biological and/or medical conditions; Mechanical and biological properties of membrane biomaterials; Cellular and tissue engineering, physiological, biophysical, biochemical bioengineering aspects; Implant failure fields and degradation of implants. Biomimetics engineering and materials including system analysis as supporter for aged people and as rehabilitation; Bioengineering and materials technology as applied to the decontamination against environmental problems; Biosensors, bioreactors, bioprocess instrumentation and control system; Application to food engineering; Standardization problems on biomaterials and related products; Assessment of reliability and safety of biomedical materials and man-machine systems; and Product liability of biomaterials and related products.
期刊最新文献
Extract from Falcaria vulgaris loaded with exosomes for the treatment of hypertension in pregnant mice: In vitro and In vivo investigations. Acupuncture navigation method integrated with augmented reality. Assessment of decellularization strategy and biocompatibility testing of full-thickness abdominal wall to produce a tissue-engineered graft. Effect of bioceramic inclusions on gel-cast aliphatic polymer membranes for bone tissue engineering applications: An in vitro study. Promotion of maturation in CDM3-induced embryonic stem cell-derived cardiomyocytes by palmitic acid.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1