牙髓治疗漂白上颌门牙有和无桩修复的加速抗疲劳性和颜色稳定性。

IF 0.9 Q3 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Esthetic Dentistry Pub Date : 2023-02-03
Adriana Lemos Mori Ubaldini, Maja Chmielewska, Mauro Luciano Baesso, Hadjir Haghparast, Pascal Magne
{"title":"牙髓治疗漂白上颌门牙有和无桩修复的加速抗疲劳性和颜色稳定性。","authors":"Adriana Lemos Mori Ubaldini,&nbsp;Maja Chmielewska,&nbsp;Mauro Luciano Baesso,&nbsp;Hadjir Haghparast,&nbsp;Pascal Magne","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The present study aimed to assess fatigue resistance and color modifications of endodontically treated incisors (ETIs) submitted to internal bleaching and restored using three different techniques.</p><p><strong>Materials and methods: </strong>Forty-five maxillary central incisors received endodontic treatment and were internally bleached. After the completion of bleaching, the ETIs were divided into three groups (n = 15) according to the different restoration procedures: 1) glass-ionomer cement base covered with composite resin (GI); 2) short fiber-reinforced composite resin base with composite resin (SF); 3) composite resin restoration over a fiberglass post (FP). Specimens were subjected to accelerated fatigue testing: frequency of 5 Hz, beginning with a load of 100 N for 5000 cycles and a 25-N load increase applied every 1700 cycles until a load of 1200 N was reached. Samples were loaded until fracture. The Kaplan-Meier survival analysis with the log-rank post hoc test were performed (α = 0.05). Tooth color was measured 4 weeks after the bleaching treatment and again after the final restoration procedure using a spectrophotometer and the Commission Internationale de l'Eclairage (CIE) L*a*b* system. L* values of the specimens were analyzed using the Shapiro-Wilk and paired sample t tests (α = 0.05).</p><p><strong>Results: </strong>All groups showed similar survival mean cycles until failure (P = 0.332) and presented a major number of nonrestorable failures. The GI group presented the lowest number of nonrepairable fractures (GI = 68%, SF = 79%, FP = 86%) and showed the most stable L* value (P = 0.987).</p><p><strong>Conclusions: </strong>The fatigue survival of internally bleached ETIs was not affected by the restorative technique utilized. Retaining the glass-ionomer base and covering the surface with composite resin should provide optimal color stability.</p>","PeriodicalId":46271,"journal":{"name":"International Journal of Esthetic Dentistry","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accelerated fatigue resistance and color stability of endodontically treated bleached maxillary incisors restored with and without a post.\",\"authors\":\"Adriana Lemos Mori Ubaldini,&nbsp;Maja Chmielewska,&nbsp;Mauro Luciano Baesso,&nbsp;Hadjir Haghparast,&nbsp;Pascal Magne\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The present study aimed to assess fatigue resistance and color modifications of endodontically treated incisors (ETIs) submitted to internal bleaching and restored using three different techniques.</p><p><strong>Materials and methods: </strong>Forty-five maxillary central incisors received endodontic treatment and were internally bleached. After the completion of bleaching, the ETIs were divided into three groups (n = 15) according to the different restoration procedures: 1) glass-ionomer cement base covered with composite resin (GI); 2) short fiber-reinforced composite resin base with composite resin (SF); 3) composite resin restoration over a fiberglass post (FP). Specimens were subjected to accelerated fatigue testing: frequency of 5 Hz, beginning with a load of 100 N for 5000 cycles and a 25-N load increase applied every 1700 cycles until a load of 1200 N was reached. Samples were loaded until fracture. The Kaplan-Meier survival analysis with the log-rank post hoc test were performed (α = 0.05). Tooth color was measured 4 weeks after the bleaching treatment and again after the final restoration procedure using a spectrophotometer and the Commission Internationale de l'Eclairage (CIE) L*a*b* system. L* values of the specimens were analyzed using the Shapiro-Wilk and paired sample t tests (α = 0.05).</p><p><strong>Results: </strong>All groups showed similar survival mean cycles until failure (P = 0.332) and presented a major number of nonrestorable failures. The GI group presented the lowest number of nonrepairable fractures (GI = 68%, SF = 79%, FP = 86%) and showed the most stable L* value (P = 0.987).</p><p><strong>Conclusions: </strong>The fatigue survival of internally bleached ETIs was not affected by the restorative technique utilized. Retaining the glass-ionomer base and covering the surface with composite resin should provide optimal color stability.</p>\",\"PeriodicalId\":46271,\"journal\":{\"name\":\"International Journal of Esthetic Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-02-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Esthetic Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Esthetic Dentistry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在评估牙髓治疗门牙(ETIs)进行内漂白和使用三种不同的技术修复后的抗疲劳性和颜色变化。材料与方法:45个上颌中切牙进行根管治疗并进行内漂白。漂白完成后,根据修复方式的不同,将ETIs分为3组(n = 15): 1)玻璃离子水泥基覆盖复合树脂(GI);2)短纤维增强复合树脂基材采用复合树脂(SF);3)复合树脂修复在玻璃纤维桩(FP)。试样进行加速疲劳试验:频率为5 Hz,从100 N的载荷开始,进行5000次循环,每1700次循环增加25 N的载荷,直到达到1200 N的载荷。试样加载至断裂。Kaplan-Meier生存分析和log-rank事后检验(α = 0.05)。在漂白处理4周后和最终修复程序后,使用分光光度计和CIE l *a*b*系统再次测量牙齿颜色。采用Shapiro-Wilk检验和配对样本t检验对标本的L*值进行分析(α = 0.05)。结果:各组失败前的平均生存周期相似(P = 0.332),且出现大量不可恢复的失败。GI组不可修复骨折发生率最低(GI = 68%, SF = 79%, FP = 86%), L*值最稳定(P = 0.987)。结论:采用的修复技术不影响内漂白ETIs的疲劳存活。保留玻璃离子基和表面覆盖复合树脂应提供最佳的颜色稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accelerated fatigue resistance and color stability of endodontically treated bleached maxillary incisors restored with and without a post.

Purpose: The present study aimed to assess fatigue resistance and color modifications of endodontically treated incisors (ETIs) submitted to internal bleaching and restored using three different techniques.

Materials and methods: Forty-five maxillary central incisors received endodontic treatment and were internally bleached. After the completion of bleaching, the ETIs were divided into three groups (n = 15) according to the different restoration procedures: 1) glass-ionomer cement base covered with composite resin (GI); 2) short fiber-reinforced composite resin base with composite resin (SF); 3) composite resin restoration over a fiberglass post (FP). Specimens were subjected to accelerated fatigue testing: frequency of 5 Hz, beginning with a load of 100 N for 5000 cycles and a 25-N load increase applied every 1700 cycles until a load of 1200 N was reached. Samples were loaded until fracture. The Kaplan-Meier survival analysis with the log-rank post hoc test were performed (α = 0.05). Tooth color was measured 4 weeks after the bleaching treatment and again after the final restoration procedure using a spectrophotometer and the Commission Internationale de l'Eclairage (CIE) L*a*b* system. L* values of the specimens were analyzed using the Shapiro-Wilk and paired sample t tests (α = 0.05).

Results: All groups showed similar survival mean cycles until failure (P = 0.332) and presented a major number of nonrestorable failures. The GI group presented the lowest number of nonrepairable fractures (GI = 68%, SF = 79%, FP = 86%) and showed the most stable L* value (P = 0.987).

Conclusions: The fatigue survival of internally bleached ETIs was not affected by the restorative technique utilized. Retaining the glass-ionomer base and covering the surface with composite resin should provide optimal color stability.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Esthetic Dentistry
International Journal of Esthetic Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.50
自引率
7.10%
发文量
10
期刊最新文献
Social Media. IJED Espresso. Treatment protocol of dental bleaching and resin infiltration for white spot lesions. Social Media. IJED Espresso.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1