采用临床验证的基于人工智能的技术与手工方法获得的创面面积测量值的比较以及测量方法对清创代码报销成本的影响。

IF 1.4 4区 医学 Q3 DERMATOLOGY Wounds : a compendium of clinical research and practice Pub Date : 2023-10-01
Misael C Alonso, Heba Tallah Mohammed, Robert D Fraser, Jose L Ramirez Garcia Luna, David Mannion
{"title":"采用临床验证的基于人工智能的技术与手工方法获得的创面面积测量值的比较以及测量方法对清创代码报销成本的影响。","authors":"Misael C Alonso, Heba Tallah Mohammed, Robert D Fraser, Jose L Ramirez Garcia Luna, David Mannion","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Evidence shows that ongoing accurate wound assessments using valid and reliable measurement methods is essential to effective wound monitoring and better wound care management. Relying on subjective interpretation in measuring wound dimensions and assuming a rectilinear shape of all wounds renders an inconsistent and inaccurate wound area measurement.</p><p><strong>Objective: </strong>The authors investigated the discrepancy in wound area measurements using a DWMS versus TPR methods and compared debridement codes submitted for reimbursement by assessment method.</p><p><strong>Methods: </strong>The width and length of 177 wounds in 56 patients were measured at an outpatient clinic in the United States using the TPR method (width × length formula) and a DWMS (traced wound dimensions). The maximal allowable payment for debridement was calculated for both methods using the reported CPT codes based on each 20-cm2 estimated surface area.</p><p><strong>Results: </strong>The average wound surface area was significantly higher with the TPR method than with the DWMS (20.20 and 12.81, respectively; P = .025). For patients with dark skin tones, ill-defined wound edges, irregular wound shapes, unhealthy tissues, and the presence of necrotic tissues, the use of the DWMS resulted in significantly lower mean differences in wound area measurements of 14.4 cm2 (P < .008), 8.2 cm2 (P = .040), 6.8 cm2 (P = .045), 13.1 cm2 (P = .036), and 7.6 cm2 (P = .043), respectively, compared with the TPR method. Use of the DWMS for wound surface area measurement resulted in a 10.6% lower reimbursement amount for debridement, with 82 fewer submitted codes, compared with the TPR method.</p><p><strong>Conclusions: </strong>Compared with the DWMS, TPR measurements overestimated wound area more than 36.6%. This overestimation was associated with dark skin tones and wounds with irregular edges, irregular shapes, and necrotic tissue.</p>","PeriodicalId":23752,"journal":{"name":"Wounds : a compendium of clinical research and practice","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of wound surface area measurements obtained using clinically validated artificial intelligence-based technology versus manual methods and the effect of measurement method on debridement code reimbursement cost.\",\"authors\":\"Misael C Alonso, Heba Tallah Mohammed, Robert D Fraser, Jose L Ramirez Garcia Luna, David Mannion\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Evidence shows that ongoing accurate wound assessments using valid and reliable measurement methods is essential to effective wound monitoring and better wound care management. Relying on subjective interpretation in measuring wound dimensions and assuming a rectilinear shape of all wounds renders an inconsistent and inaccurate wound area measurement.</p><p><strong>Objective: </strong>The authors investigated the discrepancy in wound area measurements using a DWMS versus TPR methods and compared debridement codes submitted for reimbursement by assessment method.</p><p><strong>Methods: </strong>The width and length of 177 wounds in 56 patients were measured at an outpatient clinic in the United States using the TPR method (width × length formula) and a DWMS (traced wound dimensions). The maximal allowable payment for debridement was calculated for both methods using the reported CPT codes based on each 20-cm2 estimated surface area.</p><p><strong>Results: </strong>The average wound surface area was significantly higher with the TPR method than with the DWMS (20.20 and 12.81, respectively; P = .025). For patients with dark skin tones, ill-defined wound edges, irregular wound shapes, unhealthy tissues, and the presence of necrotic tissues, the use of the DWMS resulted in significantly lower mean differences in wound area measurements of 14.4 cm2 (P < .008), 8.2 cm2 (P = .040), 6.8 cm2 (P = .045), 13.1 cm2 (P = .036), and 7.6 cm2 (P = .043), respectively, compared with the TPR method. Use of the DWMS for wound surface area measurement resulted in a 10.6% lower reimbursement amount for debridement, with 82 fewer submitted codes, compared with the TPR method.</p><p><strong>Conclusions: </strong>Compared with the DWMS, TPR measurements overestimated wound area more than 36.6%. This overestimation was associated with dark skin tones and wounds with irregular edges, irregular shapes, and necrotic tissue.</p>\",\"PeriodicalId\":23752,\"journal\":{\"name\":\"Wounds : a compendium of clinical research and practice\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wounds : a compendium of clinical research and practice\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DERMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wounds : a compendium of clinical research and practice","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DERMATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:证据表明,使用有效和可靠的测量方法进行持续准确的伤口评估对于有效的伤口监测和更好的伤口护理管理至关重要。在测量伤口尺寸时,依靠主观解释,假设所有伤口都是直线形状,会导致伤口面积测量不一致和不准确。目的:探讨采用DWMS和TPR方法测量创面面积的差异,并比较通过评估方法提交报销的清创代码。方法:采用TPR法(宽度×长度公式)和DWMS法(追踪创面尺寸)测量56例美国门诊177例创面的宽度和长度。根据每20平方厘米的估计表面面积,使用报告的CPT代码计算两种方法的最大允许清创费用。结果:TPR法的平均创面面积显著高于DWMS法(分别为20.20和12.81);P = .025)。对于肤色深、创面边缘不清晰、创面形状不规则、组织不健康、存在坏死组织的患者,与TPR法相比,使用DWMS的创面面积测量的平均差异显著降低,分别为14.4 cm2 (P < 0.008)、8.2 cm2 (P = 0.040)、6.8 cm2 (P = 0.045)、13.1 cm2 (P = 0.036)和7.6 cm2 (P = 0.043)。与TPR方法相比,使用DWMS进行创面面积测量导致清创报销金额降低10.6%,提交的代码减少82个。结论:与DWMS相比,TPR测量高估创面面积超过36.6%。这种高估与肤色深、伤口边缘不规则、形状不规则和组织坏死有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of wound surface area measurements obtained using clinically validated artificial intelligence-based technology versus manual methods and the effect of measurement method on debridement code reimbursement cost.

Background: Evidence shows that ongoing accurate wound assessments using valid and reliable measurement methods is essential to effective wound monitoring and better wound care management. Relying on subjective interpretation in measuring wound dimensions and assuming a rectilinear shape of all wounds renders an inconsistent and inaccurate wound area measurement.

Objective: The authors investigated the discrepancy in wound area measurements using a DWMS versus TPR methods and compared debridement codes submitted for reimbursement by assessment method.

Methods: The width and length of 177 wounds in 56 patients were measured at an outpatient clinic in the United States using the TPR method (width × length formula) and a DWMS (traced wound dimensions). The maximal allowable payment for debridement was calculated for both methods using the reported CPT codes based on each 20-cm2 estimated surface area.

Results: The average wound surface area was significantly higher with the TPR method than with the DWMS (20.20 and 12.81, respectively; P = .025). For patients with dark skin tones, ill-defined wound edges, irregular wound shapes, unhealthy tissues, and the presence of necrotic tissues, the use of the DWMS resulted in significantly lower mean differences in wound area measurements of 14.4 cm2 (P < .008), 8.2 cm2 (P = .040), 6.8 cm2 (P = .045), 13.1 cm2 (P = .036), and 7.6 cm2 (P = .043), respectively, compared with the TPR method. Use of the DWMS for wound surface area measurement resulted in a 10.6% lower reimbursement amount for debridement, with 82 fewer submitted codes, compared with the TPR method.

Conclusions: Compared with the DWMS, TPR measurements overestimated wound area more than 36.6%. This overestimation was associated with dark skin tones and wounds with irregular edges, irregular shapes, and necrotic tissue.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.50
自引率
11.80%
发文量
77
审稿时长
6-12 weeks
期刊介绍: Wounds is the most widely read, peer-reviewed journal focusing on wound care and wound research. The information disseminated to our readers includes valuable research and commentaries on tissue repair and regeneration, biology and biochemistry of wound healing, and clinical management of various wound etiologies. Our multidisciplinary readership consists of dermatologists, general surgeons, plastic surgeons, vascular surgeons, internal medicine/family practitioners, podiatrists, gerontologists, researchers in industry or academia (PhDs), orthopedic surgeons, infectious disease physicians, nurse practitioners, and physician assistants. These practitioners must be well equipped to deal with a myriad of chronic wound conditions affecting their patients including vascular disease, diabetes, obesity, dermatological disorders, and more. Whether dealing with a traumatic wound, a surgical or non-skin wound, a burn injury, or a diabetic foot ulcer, wound care professionals turn to Wounds for the latest in research and practice in this ever-growing field of medicine.
期刊最新文献
Diving deep into healing: the promising role of fish skin in wound recovery. Effectiveness of negative pressure wound therapy in treating diabetic foot ulcers: a systematic review and meta-analysis of randomized controlled trials. Evaluating the number of cellular and/or tissue-based product applications required to treat diabetic foot ulcers and venous leg ulcers in non-hospital outpatient department settings. Skin cancer or locally advanced mammary carcinoma: a discussion of cutaneous pathology on the male chest. Use of silver collagen oxidized regenerated cellulose dressings in conjunction with negative pressure wound therapy: expert panel consensus recommendations.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1