Zelal Zuhal Kaya, Muhittin Serdar, Fehime Aksungar, Meltem Kilercik, Mustafa Serteser, Ahmet Tarik Baykal
{"title":"基质辅助激光解吸/电离飞行时间质谱法快速检测血清游离轻链。","authors":"Zelal Zuhal Kaya, Muhittin Serdar, Fehime Aksungar, Meltem Kilercik, Mustafa Serteser, Ahmet Tarik Baykal","doi":"10.1177/14690667231153616","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> Serum free light chain (FLC) measurements are increasingly prominent for patients with plasma cell disorders (PCDs) in screening, prognostic stratification, and monitoring therapy responses. <b>Objectives:</b> We aimed to develop a sensitive, reliable, and accurate method for diagnosing PCDs that can notably decrease the time and cost of current methods. <b>Methods:</b> Here, we present a novel approach for FLC measurement using immunoenrichment on micro-affinity chromatography in combination with matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) detection. In this study, serum free kappa (κ) and free lambda (λ) light chain (LC) levels in the serum of 105 patients were compared between the nephelometric serum FLC quantification and MALDI-TOF MS detection. <b>Results:</b> Cohen's kappa coefficient between the MALDI-TOF MS-based method and the FLC assay revealed an almost perfect agreement in the case of normal (negative) results (κ = 0.92; 95% confidence interval (CI): 0.837 to 0.968) and a good agreement in the case of increased (positive) results (κ = 0.76; 95% CI: 0.608 to 0.870). In Spearman's correlation analysis, the best correlation was found between serum free κ/λ ratios (r = 0.628, 0.496 to 0.732; <i>p</i> <0.0001). Our method showed sensitivity (92.5%) and specificity (76.3%) for discrimination between the κ/λ FLC ratio compared to the serum FLC assay. <b>Conclusion:</b> The proposed method can significantly contribute to diagnosing and monitoring PCDs as it can significantly be time-saving, cost-effective in FLC measurement.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rapid detection of serum free light chains by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.\",\"authors\":\"Zelal Zuhal Kaya, Muhittin Serdar, Fehime Aksungar, Meltem Kilercik, Mustafa Serteser, Ahmet Tarik Baykal\",\"doi\":\"10.1177/14690667231153616\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Introduction:</b> Serum free light chain (FLC) measurements are increasingly prominent for patients with plasma cell disorders (PCDs) in screening, prognostic stratification, and monitoring therapy responses. <b>Objectives:</b> We aimed to develop a sensitive, reliable, and accurate method for diagnosing PCDs that can notably decrease the time and cost of current methods. <b>Methods:</b> Here, we present a novel approach for FLC measurement using immunoenrichment on micro-affinity chromatography in combination with matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) detection. In this study, serum free kappa (κ) and free lambda (λ) light chain (LC) levels in the serum of 105 patients were compared between the nephelometric serum FLC quantification and MALDI-TOF MS detection. <b>Results:</b> Cohen's kappa coefficient between the MALDI-TOF MS-based method and the FLC assay revealed an almost perfect agreement in the case of normal (negative) results (κ = 0.92; 95% confidence interval (CI): 0.837 to 0.968) and a good agreement in the case of increased (positive) results (κ = 0.76; 95% CI: 0.608 to 0.870). In Spearman's correlation analysis, the best correlation was found between serum free κ/λ ratios (r = 0.628, 0.496 to 0.732; <i>p</i> <0.0001). Our method showed sensitivity (92.5%) and specificity (76.3%) for discrimination between the κ/λ FLC ratio compared to the serum FLC assay. <b>Conclusion:</b> The proposed method can significantly contribute to diagnosing and monitoring PCDs as it can significantly be time-saving, cost-effective in FLC measurement.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1177/14690667231153616\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/14690667231153616","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Rapid detection of serum free light chains by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.
Introduction: Serum free light chain (FLC) measurements are increasingly prominent for patients with plasma cell disorders (PCDs) in screening, prognostic stratification, and monitoring therapy responses. Objectives: We aimed to develop a sensitive, reliable, and accurate method for diagnosing PCDs that can notably decrease the time and cost of current methods. Methods: Here, we present a novel approach for FLC measurement using immunoenrichment on micro-affinity chromatography in combination with matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) detection. In this study, serum free kappa (κ) and free lambda (λ) light chain (LC) levels in the serum of 105 patients were compared between the nephelometric serum FLC quantification and MALDI-TOF MS detection. Results: Cohen's kappa coefficient between the MALDI-TOF MS-based method and the FLC assay revealed an almost perfect agreement in the case of normal (negative) results (κ = 0.92; 95% confidence interval (CI): 0.837 to 0.968) and a good agreement in the case of increased (positive) results (κ = 0.76; 95% CI: 0.608 to 0.870). In Spearman's correlation analysis, the best correlation was found between serum free κ/λ ratios (r = 0.628, 0.496 to 0.732; p <0.0001). Our method showed sensitivity (92.5%) and specificity (76.3%) for discrimination between the κ/λ FLC ratio compared to the serum FLC assay. Conclusion: The proposed method can significantly contribute to diagnosing and monitoring PCDs as it can significantly be time-saving, cost-effective in FLC measurement.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.