离子色谱-串联质谱法分析生物体液中神经毒剂降解产物。

IF 2.8 4区 医学 Q2 TOXICOLOGY Forensic Toxicology Pub Date : 2023-01-01 DOI:10.1007/s11419-022-00633-x
Mai Otsuka, Hajime Miyaguchi
{"title":"离子色谱-串联质谱法分析生物体液中神经毒剂降解产物。","authors":"Mai Otsuka,&nbsp;Hajime Miyaguchi","doi":"10.1007/s11419-022-00633-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The detection of hydrolysis products of nerve agents (alkyl methylphosphonic acids; RMPAs) in biological samples from victims is important to confirm exposure to nerve agents. However, analysis of RMPAs is difficult due to their high hydrophilicity. The aim of this study was to develop ion chromatography-tandem mass spectrometry (IC-MS/MS) methods using commercially available equipment and columns to analyze RMPAs in human urine and serum with high sensitivity and without using complicate techniques.</p><p><strong>Methods: </strong>A Dionex IonPac AS11-HC anion-exchange column was used to analyze six RMPAs (MPA, EMPA, IMPA, <sup>i</sup>BuMPA, CHMPA, and PMPA). For pretreatments of biological fluids, we developed two pretreatment methods (Method 1: dilution and ultrafiltration; Method 2: removal of chloride ions with Ag cartridges).</p><p><strong>Results: </strong>Six RMPAs including highly hydrophilic methylphosphonic acid and ethyl methylphosphonic acid could be analyzed with sufficient retention times and peak shape. The detection limits of RMPAs were improved using Dionex OnGuard II Ba/Ag/H cartridges and MetaSEP IC-Ag cartridges (urine: 0.5-5 ng/mL; serum: 1-5 ng/mL). These methods were also applied to the test samples for the Organisation for the Prohibition of Chemical Weapons Biomedical Proficiency Tests.</p><p><strong>Conclusions: </strong>RMPAs could be sufficiently analyzed by IC-MS/MS. In addition, the limits of detection were superior to those obtained in our previous study involving LC-MS/MS or derivatization-LC-MS/MS method. For analysis of biological samples, an appropriate pretreatment method can be chosen according to the amount of sample available for analysis and expected RMPA concentrations.</p>","PeriodicalId":12329,"journal":{"name":"Forensic Toxicology","volume":"41 1","pages":"71-80"},"PeriodicalIF":2.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Analysis of degradation products of nerve agents in biological fluids by ion chromatography-tandem mass spectrometry.\",\"authors\":\"Mai Otsuka,&nbsp;Hajime Miyaguchi\",\"doi\":\"10.1007/s11419-022-00633-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The detection of hydrolysis products of nerve agents (alkyl methylphosphonic acids; RMPAs) in biological samples from victims is important to confirm exposure to nerve agents. However, analysis of RMPAs is difficult due to their high hydrophilicity. The aim of this study was to develop ion chromatography-tandem mass spectrometry (IC-MS/MS) methods using commercially available equipment and columns to analyze RMPAs in human urine and serum with high sensitivity and without using complicate techniques.</p><p><strong>Methods: </strong>A Dionex IonPac AS11-HC anion-exchange column was used to analyze six RMPAs (MPA, EMPA, IMPA, <sup>i</sup>BuMPA, CHMPA, and PMPA). For pretreatments of biological fluids, we developed two pretreatment methods (Method 1: dilution and ultrafiltration; Method 2: removal of chloride ions with Ag cartridges).</p><p><strong>Results: </strong>Six RMPAs including highly hydrophilic methylphosphonic acid and ethyl methylphosphonic acid could be analyzed with sufficient retention times and peak shape. The detection limits of RMPAs were improved using Dionex OnGuard II Ba/Ag/H cartridges and MetaSEP IC-Ag cartridges (urine: 0.5-5 ng/mL; serum: 1-5 ng/mL). These methods were also applied to the test samples for the Organisation for the Prohibition of Chemical Weapons Biomedical Proficiency Tests.</p><p><strong>Conclusions: </strong>RMPAs could be sufficiently analyzed by IC-MS/MS. In addition, the limits of detection were superior to those obtained in our previous study involving LC-MS/MS or derivatization-LC-MS/MS method. For analysis of biological samples, an appropriate pretreatment method can be chosen according to the amount of sample available for analysis and expected RMPA concentrations.</p>\",\"PeriodicalId\":12329,\"journal\":{\"name\":\"Forensic Toxicology\",\"volume\":\"41 1\",\"pages\":\"71-80\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Forensic Toxicology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11419-022-00633-x\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"TOXICOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Forensic Toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11419-022-00633-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"TOXICOLOGY","Score":null,"Total":0}
引用次数: 2

摘要

目的:检测神经毒剂(烷基甲基膦酸)水解产物;受害者生物样本中的RMPAs对于确认神经毒剂暴露非常重要。然而,由于RMPAs的高亲水性,分析起来很困难。本研究的目的是建立离子色谱-串联质谱(IC-MS/MS)方法,使用市售设备和色谱柱分析人体尿液和血清中的RMPAs,灵敏度高,无需复杂的技术。方法:采用Dionex IonPac AS11-HC阴离子交换柱对6种rmpa (MPA、EMPA、IMPA、iBuMPA、CHMPA、PMPA)进行分析。对于生物流体的预处理,我们开发了两种预处理方法(方法一:稀释和超滤;方法二:用银筒去除氯离子)。结果:高亲水性甲基膦酸和乙基甲基膦酸6种RMPAs均可分析,保留时间和峰形均足够。采用Dionex OnGuard II Ba/Ag/H试剂盒和MetaSEP IC-Ag试剂盒提高RMPAs的检出限(尿:0.5 ~ 5 ng/mL;血清:1-5 ng/mL)。这些方法也适用于禁止化学武器组织生物医学能力测试的测试样本。结论:IC-MS/MS能充分分析RMPAs。此外,该方法的检出限优于我们之前的LC-MS/MS或衍生化-LC-MS/MS方法。对于生物样品的分析,可根据可供分析的样品数量和预期RMPA浓度选择合适的预处理方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of degradation products of nerve agents in biological fluids by ion chromatography-tandem mass spectrometry.

Purpose: The detection of hydrolysis products of nerve agents (alkyl methylphosphonic acids; RMPAs) in biological samples from victims is important to confirm exposure to nerve agents. However, analysis of RMPAs is difficult due to their high hydrophilicity. The aim of this study was to develop ion chromatography-tandem mass spectrometry (IC-MS/MS) methods using commercially available equipment and columns to analyze RMPAs in human urine and serum with high sensitivity and without using complicate techniques.

Methods: A Dionex IonPac AS11-HC anion-exchange column was used to analyze six RMPAs (MPA, EMPA, IMPA, iBuMPA, CHMPA, and PMPA). For pretreatments of biological fluids, we developed two pretreatment methods (Method 1: dilution and ultrafiltration; Method 2: removal of chloride ions with Ag cartridges).

Results: Six RMPAs including highly hydrophilic methylphosphonic acid and ethyl methylphosphonic acid could be analyzed with sufficient retention times and peak shape. The detection limits of RMPAs were improved using Dionex OnGuard II Ba/Ag/H cartridges and MetaSEP IC-Ag cartridges (urine: 0.5-5 ng/mL; serum: 1-5 ng/mL). These methods were also applied to the test samples for the Organisation for the Prohibition of Chemical Weapons Biomedical Proficiency Tests.

Conclusions: RMPAs could be sufficiently analyzed by IC-MS/MS. In addition, the limits of detection were superior to those obtained in our previous study involving LC-MS/MS or derivatization-LC-MS/MS method. For analysis of biological samples, an appropriate pretreatment method can be chosen according to the amount of sample available for analysis and expected RMPA concentrations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Forensic Toxicology
Forensic Toxicology TOXICOLOGY-
CiteScore
5.80
自引率
9.10%
发文量
40
审稿时长
3 months
期刊介绍: The journal Forensic Toxicology provides an international forum for publication of studies on toxic substances, drugs of abuse, doping agents, chemical warfare agents, and their metabolisms and analyses, which are related to laws and ethics. It includes original articles, reviews, mini-reviews, short communications, and case reports. Although a major focus of the journal is on the development or improvement of analytical methods for the above-mentioned chemicals in human matrices, appropriate studies with animal experiments are also published. Forensic Toxicology is the official publication of the Japanese Association of Forensic Toxicology (JAFT) and is the continuation of the Japanese Journal of Forensic Toxicology (ISSN 0915-9606).
期刊最新文献
Metabolic profiling of the synthetic cannabinoid APP-CHMINACA (PX-3) as studied by in vitro and in vivo models. Death due to unrecognized intoxication of nifedipine in an adult. Elucidation of toxic effects of 1,2-diacetylbenzene: an in silico study Bioinformatics-driven untargeted metabolomic profiling for clinical screening of methamphetamine abuse Postmortem distribution of ropivacaine and its metabolite in human body fluids and solid tissues by GC–MS/MS using standard addition method
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1