主动脉支架移植物原位开窗方法和工具的系统评价

IF 17.2 1区 工程技术 Q1 ENGINEERING, BIOMEDICAL IEEE Reviews in Biomedical Engineering Pub Date : 2021-06-01 DOI:10.1109/RBME.2021.3085484
Roberta Piazza;M. Carbone;R. N. Berchiolli;V. Ferrari;M. Ferrari;S. Condino
{"title":"主动脉支架移植物原位开窗方法和工具的系统评价","authors":"Roberta Piazza;M. Carbone;R. N. Berchiolli;V. Ferrari;M. Ferrari;S. Condino","doi":"10.1109/RBME.2021.3085484","DOIUrl":null,"url":null,"abstract":"In situ fenestration of stent-graft represents a potential option for the treatment of aortic diseases in patients unsuitable for standard endovascular repair. The best fenestration strategy to restore perfusion of collateral vessels after their coverage by an endograft depends mainly on the anatomical area. Several tools are employed as fenestration devices, including needles, radiofrequency probes, and laser systems, used in conjunction with other instrumentation to provide enough support and stability during the procedure. In this systematic review, the approaches to reach the correct fenestration site both in human, animal, and in in vitro environments are described and discussed, highlighting advantages and limitations. Both commercial and dedicated solutions for the intraoperative modification of the fabric material are reported as well. The clinical interest in this procedure has so far encouraged researchers to develop and refine both methods and tools to solve the current limitations of this technique, intending to extend the indications for endovascular treatment to a broader range of patients.","PeriodicalId":39235,"journal":{"name":"IEEE Reviews in Biomedical Engineering","volume":"16 ","pages":"348-356"},"PeriodicalIF":17.2000,"publicationDate":"2021-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/RBME.2021.3085484","citationCount":"1","resultStr":"{\"title\":\"A Systematic Review on Methods and Tools for the In Situ Fenestration of Aortic Stent-Graft\",\"authors\":\"Roberta Piazza;M. Carbone;R. N. Berchiolli;V. Ferrari;M. Ferrari;S. Condino\",\"doi\":\"10.1109/RBME.2021.3085484\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In situ fenestration of stent-graft represents a potential option for the treatment of aortic diseases in patients unsuitable for standard endovascular repair. The best fenestration strategy to restore perfusion of collateral vessels after their coverage by an endograft depends mainly on the anatomical area. Several tools are employed as fenestration devices, including needles, radiofrequency probes, and laser systems, used in conjunction with other instrumentation to provide enough support and stability during the procedure. In this systematic review, the approaches to reach the correct fenestration site both in human, animal, and in in vitro environments are described and discussed, highlighting advantages and limitations. Both commercial and dedicated solutions for the intraoperative modification of the fabric material are reported as well. The clinical interest in this procedure has so far encouraged researchers to develop and refine both methods and tools to solve the current limitations of this technique, intending to extend the indications for endovascular treatment to a broader range of patients.\",\"PeriodicalId\":39235,\"journal\":{\"name\":\"IEEE Reviews in Biomedical Engineering\",\"volume\":\"16 \",\"pages\":\"348-356\"},\"PeriodicalIF\":17.2000,\"publicationDate\":\"2021-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/RBME.2021.3085484\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Reviews in Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/9444878/\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Reviews in Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/9444878/","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 1

摘要

原位开窗支架移植物是治疗不适合标准血管内修复的主动脉疾病的一种潜在选择。内移植物覆盖侧支血管后,恢复侧支血管灌注的最佳开窗策略主要取决于解剖区域。有几种工具被用作开窗装置,包括针头、射频探头和激光系统,与其他仪器一起使用,以在手术过程中提供足够的支撑和稳定性。在这篇系统综述中,描述和讨论了在人类、动物和体外环境中达到正确开窗位置的方法,强调了优势和局限性。也报道了用于织物材料术中改性的商业和专用解决方案。到目前为止,对该手术的临床兴趣鼓励研究人员开发和完善方法和工具,以解决该技术目前的局限性,旨在将血管内治疗的适应症扩展到更广泛的患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Systematic Review on Methods and Tools for the In Situ Fenestration of Aortic Stent-Graft
In situ fenestration of stent-graft represents a potential option for the treatment of aortic diseases in patients unsuitable for standard endovascular repair. The best fenestration strategy to restore perfusion of collateral vessels after their coverage by an endograft depends mainly on the anatomical area. Several tools are employed as fenestration devices, including needles, radiofrequency probes, and laser systems, used in conjunction with other instrumentation to provide enough support and stability during the procedure. In this systematic review, the approaches to reach the correct fenestration site both in human, animal, and in in vitro environments are described and discussed, highlighting advantages and limitations. Both commercial and dedicated solutions for the intraoperative modification of the fabric material are reported as well. The clinical interest in this procedure has so far encouraged researchers to develop and refine both methods and tools to solve the current limitations of this technique, intending to extend the indications for endovascular treatment to a broader range of patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Reviews in Biomedical Engineering
IEEE Reviews in Biomedical Engineering Engineering-Biomedical Engineering
CiteScore
31.70
自引率
0.60%
发文量
93
期刊介绍: IEEE Reviews in Biomedical Engineering (RBME) serves as a platform to review the state-of-the-art and trends in the interdisciplinary field of biomedical engineering, which encompasses engineering, life sciences, and medicine. The journal aims to consolidate research and reviews for members of all IEEE societies interested in biomedical engineering. Recognizing the demand for comprehensive reviews among authors of various IEEE journals, RBME addresses this need by receiving, reviewing, and publishing scholarly works under one umbrella. It covers a broad spectrum, from historical to modern developments in biomedical engineering and the integration of technologies from various IEEE societies into the life sciences and medicine.
期刊最新文献
Foundation Model for Advancing Healthcare: Challenges, Opportunities and Future Directions. A Manual for Genome and Transcriptome Engineering. Artificial General Intelligence for Medical Imaging Analysis. A Survey of Few-Shot Learning for Biomedical Time Series. The Physiome Project and Digital Twins.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1