使用改良版GE Q肺验证RAH VQ SPECT/CT大叶定量程序。

IF 0.9 4区 医学 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Hellenic journal of nuclear medicine Pub Date : 2023-01-01 DOI:10.1967/s002449912551
Chong Ghee Chew, Benjamin Crouch, Stirling Ha, Alice Burke, Jennie Louise
{"title":"使用改良版GE Q肺验证RAH VQ SPECT/CT大叶定量程序。","authors":"Chong Ghee Chew,&nbsp;Benjamin Crouch,&nbsp;Stirling Ha,&nbsp;Alice Burke,&nbsp;Jennie Louise","doi":"10.1967/s002449912551","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The value of ventilation-perfusion (VQ) single photon emission tomography/computed tomography (SPECT/CT) lobar quantification for pre-operative assessment of lobectomy and lung volume reduction is known. Our in-house developed software, RAH ventilation perfusion SPECT/CT quantification (RAHVQSQ) has been shown to be able to identify the target lobe for collapse in bronchoscopic lung volume reduction (BLVR) for advanced emphysema. We have proven inter and intra observer reproducibility but are yet to validate the accuracy of our program. This study aims to validate the accuracy of our quantitative program through comparison with a modified version of GE Q lung which is a commercial program certified for clinical use.</p><p><strong>Subjects and methods: </strong>Ventilation-perfusion SPECT/CT data of 19 subjects from our previous study using RAHVQSQ for BLVR assessment were re-analysed using Q lung by 2 technologists independently and in a blinded fashion to determine lobar differential ventilation, perfusion and volume percentages. The data were from GE Hawkeye 4 and external CT, thus a modified version of Q lung was used. To determine interobserver variation in the 3 parameters between the 3 assessors, intraclass correlation coefficient (ICC) and Bland-Altman limits of agreement (LoA) were generated.</p><p><strong>Results: </strong>Paired comparisons between the 3 assessors had high ICC (range for ventilation: 0.69-0.97; perfusion: 0.69-0.97; volume: 0.63-0.97) and means of LoA differences close to zero (range for ventilation: -0.04 - 0.10; perfusion: 0.00-0.02; volume: -0.12 - 0.09) were noted indicative of good concordance for all parameters.</p><p><strong>Conclusion: </strong>Using VQ SPECT/CT data of participants with advanced airway disease, our study has found a close concordance of estimated differential lobar ventilation, perfusion and volume percentages using RAHVQSQ when compared with a duplicated blinded assessment using Q lung. The good concordance supports the validity of our quantitative methodology.</p>","PeriodicalId":12871,"journal":{"name":"Hellenic journal of nuclear medicine","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of RAH VQ SPECT/CT lobar quantification program using a modified version of GE Q lung.\",\"authors\":\"Chong Ghee Chew,&nbsp;Benjamin Crouch,&nbsp;Stirling Ha,&nbsp;Alice Burke,&nbsp;Jennie Louise\",\"doi\":\"10.1967/s002449912551\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The value of ventilation-perfusion (VQ) single photon emission tomography/computed tomography (SPECT/CT) lobar quantification for pre-operative assessment of lobectomy and lung volume reduction is known. Our in-house developed software, RAH ventilation perfusion SPECT/CT quantification (RAHVQSQ) has been shown to be able to identify the target lobe for collapse in bronchoscopic lung volume reduction (BLVR) for advanced emphysema. We have proven inter and intra observer reproducibility but are yet to validate the accuracy of our program. This study aims to validate the accuracy of our quantitative program through comparison with a modified version of GE Q lung which is a commercial program certified for clinical use.</p><p><strong>Subjects and methods: </strong>Ventilation-perfusion SPECT/CT data of 19 subjects from our previous study using RAHVQSQ for BLVR assessment were re-analysed using Q lung by 2 technologists independently and in a blinded fashion to determine lobar differential ventilation, perfusion and volume percentages. The data were from GE Hawkeye 4 and external CT, thus a modified version of Q lung was used. To determine interobserver variation in the 3 parameters between the 3 assessors, intraclass correlation coefficient (ICC) and Bland-Altman limits of agreement (LoA) were generated.</p><p><strong>Results: </strong>Paired comparisons between the 3 assessors had high ICC (range for ventilation: 0.69-0.97; perfusion: 0.69-0.97; volume: 0.63-0.97) and means of LoA differences close to zero (range for ventilation: -0.04 - 0.10; perfusion: 0.00-0.02; volume: -0.12 - 0.09) were noted indicative of good concordance for all parameters.</p><p><strong>Conclusion: </strong>Using VQ SPECT/CT data of participants with advanced airway disease, our study has found a close concordance of estimated differential lobar ventilation, perfusion and volume percentages using RAHVQSQ when compared with a duplicated blinded assessment using Q lung. The good concordance supports the validity of our quantitative methodology.</p>\",\"PeriodicalId\":12871,\"journal\":{\"name\":\"Hellenic journal of nuclear medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Hellenic journal of nuclear medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1967/s002449912551\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hellenic journal of nuclear medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1967/s002449912551","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:了解通气灌注(VQ)单光子发射断层扫描/计算机断层扫描(SPECT/CT)肺叶定量在肺叶切除术和肺减容术前评估中的价值。我们内部开发的软件RAH通气灌注SPECT/CT量化(RAHVQSQ)已被证明能够识别晚期肺气肿支气管镜肺减容(BLVR)中塌陷的靶叶。我们已经证明了观察者之间和内部的可重复性,但尚未验证我们程序的准确性。本研究旨在通过与GE Q肺的改良版本进行比较来验证我们定量程序的准确性,GE Q肺是一个经临床应用认证的商业程序。受试者和方法:我们之前使用RAHVQSQ进行BLVR评估的19名受试者的通气-灌注SPECT/CT数据由2名技术人员独立地以盲法使用Q肺重新分析,以确定大叶差异通气,灌注和容积百分比。数据来自GE Hawkeye 4和外置CT,因此使用改良版的Q肺。为了确定3个评估者之间3个参数的观察者间变异,我们生成了类内相关系数(ICC)和Bland-Altman一致限(LoA)。结果:3名评估者的配对比较具有较高的ICC(通气范围:0.69-0.97;灌注:0.69 - -0.97;容积:0.63-0.97),LoA平均值差接近于零(通风范围:-0.04 - 0.10;灌注:0.00 - -0.02;体积:-0.12 - 0.09)表明所有参数的一致性良好。结论:使用晚期气道疾病参与者的VQ SPECT/CT数据,我们的研究发现,与使用Q肺的重复盲法评估相比,使用RAHVQSQ估计的差异肺叶通气、灌注和容积百分比具有密切的一致性。良好的一致性支持了我们定量方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Validation of RAH VQ SPECT/CT lobar quantification program using a modified version of GE Q lung.

Objective: The value of ventilation-perfusion (VQ) single photon emission tomography/computed tomography (SPECT/CT) lobar quantification for pre-operative assessment of lobectomy and lung volume reduction is known. Our in-house developed software, RAH ventilation perfusion SPECT/CT quantification (RAHVQSQ) has been shown to be able to identify the target lobe for collapse in bronchoscopic lung volume reduction (BLVR) for advanced emphysema. We have proven inter and intra observer reproducibility but are yet to validate the accuracy of our program. This study aims to validate the accuracy of our quantitative program through comparison with a modified version of GE Q lung which is a commercial program certified for clinical use.

Subjects and methods: Ventilation-perfusion SPECT/CT data of 19 subjects from our previous study using RAHVQSQ for BLVR assessment were re-analysed using Q lung by 2 technologists independently and in a blinded fashion to determine lobar differential ventilation, perfusion and volume percentages. The data were from GE Hawkeye 4 and external CT, thus a modified version of Q lung was used. To determine interobserver variation in the 3 parameters between the 3 assessors, intraclass correlation coefficient (ICC) and Bland-Altman limits of agreement (LoA) were generated.

Results: Paired comparisons between the 3 assessors had high ICC (range for ventilation: 0.69-0.97; perfusion: 0.69-0.97; volume: 0.63-0.97) and means of LoA differences close to zero (range for ventilation: -0.04 - 0.10; perfusion: 0.00-0.02; volume: -0.12 - 0.09) were noted indicative of good concordance for all parameters.

Conclusion: Using VQ SPECT/CT data of participants with advanced airway disease, our study has found a close concordance of estimated differential lobar ventilation, perfusion and volume percentages using RAHVQSQ when compared with a duplicated blinded assessment using Q lung. The good concordance supports the validity of our quantitative methodology.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.40
自引率
6.70%
发文量
34
审稿时长
>12 weeks
期刊介绍: The Hellenic Journal of Nuclear Medicine published by the Hellenic Society of Nuclear Medicine in Thessaloniki, aims to contribute to research, to education and cover the scientific and professional interests of physicians, in the field of nuclear medicine and in medicine in general. The journal may publish papers of nuclear medicine and also papers that refer to related subjects as dosimetry, computer science, targeting of gene expression, radioimmunoassay, radiation protection, biology, cell trafficking, related historical brief reviews and other related subjects. Original papers are preferred. The journal may after special agreement publish supplements covering important subjects, dully reviewed and subscripted separately.
期刊最新文献
18F-FDG PET/CT image of NK/T cell lymphoma in the sacroiliac joint. 18F-FDG PET/CT imaging and curative effect evaluation of multiple muscular tuberculosis. A comparative review of the application value of FAPI PET/CT and 18F-FDG PET/CT in lung cancer. A head-to-head comparison of 18F-FDG PET/CT and 18F-FDG PET/MR in patients with nasopharyngeal carcinoma under different disease settings. Differentiated thyroid cancer with osteo-granulomatousinflammation: A case report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1