[经椎弓根脊柱内固定中骨-螺钉界面的生物力学研究]。

Acta ortopedica mexicana Pub Date : 2022-05-01
A Alpízar-Aguirre, R A González-Carbonell, A Ortiz-Prado, V H Jacobo-Armendáriz
{"title":"[经椎弓根脊柱内固定中骨-螺钉界面的生物力学研究]。","authors":"A Alpízar-Aguirre,&nbsp;R A González-Carbonell,&nbsp;A Ortiz-Prado,&nbsp;V H Jacobo-Armendáriz","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Implant loosening, catastrophic failure of the bone-screw interface, material migration, and loss of stability of the fixation component assembly constitute a serious complication in adult spinal surgery. The contribution of biomechanics is based on experimental measurement and simulation of transpedicular spinal fixations. The cortical insertion trajectory showed an increase in the resistance of the screw-bone interface with respect to the pedicle insertion trajectory, both for axial traction forces to the screw and for stress distribution in the vertebra. The double-threaded screws and standard pedicle screws had similar strength. Partially threaded screws with four-thread showed better resistance to fatigue in terms of a higher failure load and number of cycles to fail. Cement or hydroxyapatite augmented screws with also showed a better fatigue resistance in osteoporotic vertebrae. Rigid segment simulations confirmed the presence of higher stresses on the intervertebral discs causing damage to adjacent segments. The posterior body of the vertebra may be subjected to high stresses, in the bone-screw interface, being this bone region more susceptible to failure.</p>","PeriodicalId":7081,"journal":{"name":"Acta ortopedica mexicana","volume":"36 3","pages":"172-178"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Biomechanics of the bone-screw interface in transpedicular spinal instrumentation].\",\"authors\":\"A Alpízar-Aguirre,&nbsp;R A González-Carbonell,&nbsp;A Ortiz-Prado,&nbsp;V H Jacobo-Armendáriz\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Implant loosening, catastrophic failure of the bone-screw interface, material migration, and loss of stability of the fixation component assembly constitute a serious complication in adult spinal surgery. The contribution of biomechanics is based on experimental measurement and simulation of transpedicular spinal fixations. The cortical insertion trajectory showed an increase in the resistance of the screw-bone interface with respect to the pedicle insertion trajectory, both for axial traction forces to the screw and for stress distribution in the vertebra. The double-threaded screws and standard pedicle screws had similar strength. Partially threaded screws with four-thread showed better resistance to fatigue in terms of a higher failure load and number of cycles to fail. Cement or hydroxyapatite augmented screws with also showed a better fatigue resistance in osteoporotic vertebrae. Rigid segment simulations confirmed the presence of higher stresses on the intervertebral discs causing damage to adjacent segments. The posterior body of the vertebra may be subjected to high stresses, in the bone-screw interface, being this bone region more susceptible to failure.</p>\",\"PeriodicalId\":7081,\"journal\":{\"name\":\"Acta ortopedica mexicana\",\"volume\":\"36 3\",\"pages\":\"172-178\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta ortopedica mexicana\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta ortopedica mexicana","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在成人脊柱手术中,植入物松动、骨-螺钉界面的灾难性失效、材料迁移和固定组件组件稳定性的丧失是严重的并发症。生物力学的贡献是基于经椎弓根脊柱固定的实验测量和模拟。皮质插入轨迹显示螺钉-骨界面相对于椎弓根插入轨迹的阻力增加,无论是对螺钉的轴向牵引力还是椎体的应力分布。双螺纹螺钉与标准椎弓根螺钉强度相近。四螺纹的部分螺纹螺钉在更高的失效载荷和失效循环次数方面表现出更好的抗疲劳性。水泥或羟基磷灰石增强螺钉在骨质疏松椎体中也表现出更好的抗疲劳性。刚性节段模拟证实椎间盘上存在较高的应力,导致相邻节段损伤。椎体后侧可能在骨-螺钉界面处承受高应力,因此该骨区更容易发生断裂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Biomechanics of the bone-screw interface in transpedicular spinal instrumentation].

Implant loosening, catastrophic failure of the bone-screw interface, material migration, and loss of stability of the fixation component assembly constitute a serious complication in adult spinal surgery. The contribution of biomechanics is based on experimental measurement and simulation of transpedicular spinal fixations. The cortical insertion trajectory showed an increase in the resistance of the screw-bone interface with respect to the pedicle insertion trajectory, both for axial traction forces to the screw and for stress distribution in the vertebra. The double-threaded screws and standard pedicle screws had similar strength. Partially threaded screws with four-thread showed better resistance to fatigue in terms of a higher failure load and number of cycles to fail. Cement or hydroxyapatite augmented screws with also showed a better fatigue resistance in osteoporotic vertebrae. Rigid segment simulations confirmed the presence of higher stresses on the intervertebral discs causing damage to adjacent segments. The posterior body of the vertebra may be subjected to high stresses, in the bone-screw interface, being this bone region more susceptible to failure.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Functional results after shoulder hemiarthroplasty for proximal humerus fracture: experience in our center]. [Impact of the nail diameter on consolidation of tibial diaphyseal fractures. Retrospective analysis of 96 patients]. Evaluation and management of osteochondral lesions of the talus in skeletally immature patients. What is the degree of variability in formal training for pediatric orthopedic surgeons performing scoliosis surgery? [Surgical wound dehiscence and exposed hardware. Infection foretold?]
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1