{"title":"仔猪耳静脉非手术颈外静脉置管。","authors":"S K Ringer, A Schmid, M Weiss, S Ohlerth, N Spielmann, N G Clausen","doi":"10.1177/00236772231167224","DOIUrl":null,"url":null,"abstract":"<p><p>The objective of this study was to investigate the feasibility of external jugular vein catheterization through an ear vein in piglets. Forty-six sevoflurane-midazolam anaesthetized piglets were included. External jugular vein catheterization was conducted through the ear vein using the Seldinger technique. Part 1 (<i>n</i> = 27): optimal puncture site was based on the deltoid tuberosity as a landmark to reach the external jugular vein. The final position of the catheter was verified in 25 piglets using computer tomography. Catheterization time was recorded and patency of the catheter assessed by repeated blood sampling for up to 4 h. Part 2 (<i>n</i> = 19): ear vein catheterization was without taking into account any landmarks. Functionality for blood sampling was evaluated as described in part 1. Catheter advancement was possible in 25/27 and 18/19 piglets in parts 1 and 2, respectively. Median (range) time required for successful catheterization was 1.95 (1-10) min (<i>n</i> = 38). The deltoid tuberosity was a good landmark to reach the external jugular vein. But blood sampling was also possible through catheters ending slightly cranial to the external jugular vein. Despite successful catheter advancement, blood sampling was not possible from one catheter in each part of the study (total: two piglets). One of these catheters presented luminal damage, while the other one presented as normal after being removed from the animal. Summarizing, central vein catheterization through the ear vein was feasible in 93.5% and repeated blood sampling was possible in 89.1% of the piglets (<i>n</i> = 46).</p>","PeriodicalId":18013,"journal":{"name":"Laboratory Animals","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Non-surgical external jugular vein catheterization using an ear vein access in piglets.\",\"authors\":\"S K Ringer, A Schmid, M Weiss, S Ohlerth, N Spielmann, N G Clausen\",\"doi\":\"10.1177/00236772231167224\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The objective of this study was to investigate the feasibility of external jugular vein catheterization through an ear vein in piglets. Forty-six sevoflurane-midazolam anaesthetized piglets were included. External jugular vein catheterization was conducted through the ear vein using the Seldinger technique. Part 1 (<i>n</i> = 27): optimal puncture site was based on the deltoid tuberosity as a landmark to reach the external jugular vein. The final position of the catheter was verified in 25 piglets using computer tomography. Catheterization time was recorded and patency of the catheter assessed by repeated blood sampling for up to 4 h. Part 2 (<i>n</i> = 19): ear vein catheterization was without taking into account any landmarks. Functionality for blood sampling was evaluated as described in part 1. Catheter advancement was possible in 25/27 and 18/19 piglets in parts 1 and 2, respectively. Median (range) time required for successful catheterization was 1.95 (1-10) min (<i>n</i> = 38). The deltoid tuberosity was a good landmark to reach the external jugular vein. But blood sampling was also possible through catheters ending slightly cranial to the external jugular vein. Despite successful catheter advancement, blood sampling was not possible from one catheter in each part of the study (total: two piglets). One of these catheters presented luminal damage, while the other one presented as normal after being removed from the animal. Summarizing, central vein catheterization through the ear vein was feasible in 93.5% and repeated blood sampling was possible in 89.1% of the piglets (<i>n</i> = 46).</p>\",\"PeriodicalId\":18013,\"journal\":{\"name\":\"Laboratory Animals\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laboratory Animals\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/00236772231167224\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/4/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Animals","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00236772231167224","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/4/19 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是探讨经耳静脉置入仔猪颈外静脉的可行性。纳入46头七氟咪达唑仑麻醉仔猪。采用Seldinger技术经耳静脉置管颈外静脉。第一部分(n = 27):最佳穿刺位置以三角结节为标志到达颈外静脉。通过计算机断层扫描在25头仔猪中验证了导管的最终位置。记录置管时间,通过反复采血评估导管通畅程度,持续4小时。第2部分(n = 19):耳静脉置管不考虑任何标志。如第1部分所述,对血液采样的功能进行了评估。在第1部分和第2部分中,分别有25/27和18/19头仔猪可以将导管推进。成功置管所需时间中位数(范围)为1.95 (1-10)min (n = 38)。三角结节是到达颈外静脉的良好标志。但也可以通过导管进行血液取样,导管的末端略高于颅部,直至颈外静脉。尽管导管进展顺利,但不可能在研究的每一部分(总共2头仔猪)都从一根导管中采集血液。其中一根导管出现管腔损伤,而另一根在从动物身上取出后表现正常。综上所述,93.5%的仔猪可以通过耳静脉中心静脉置管,89.1%的仔猪(n = 46)可以重复采血。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Non-surgical external jugular vein catheterization using an ear vein access in piglets.

The objective of this study was to investigate the feasibility of external jugular vein catheterization through an ear vein in piglets. Forty-six sevoflurane-midazolam anaesthetized piglets were included. External jugular vein catheterization was conducted through the ear vein using the Seldinger technique. Part 1 (n = 27): optimal puncture site was based on the deltoid tuberosity as a landmark to reach the external jugular vein. The final position of the catheter was verified in 25 piglets using computer tomography. Catheterization time was recorded and patency of the catheter assessed by repeated blood sampling for up to 4 h. Part 2 (n = 19): ear vein catheterization was without taking into account any landmarks. Functionality for blood sampling was evaluated as described in part 1. Catheter advancement was possible in 25/27 and 18/19 piglets in parts 1 and 2, respectively. Median (range) time required for successful catheterization was 1.95 (1-10) min (n = 38). The deltoid tuberosity was a good landmark to reach the external jugular vein. But blood sampling was also possible through catheters ending slightly cranial to the external jugular vein. Despite successful catheter advancement, blood sampling was not possible from one catheter in each part of the study (total: two piglets). One of these catheters presented luminal damage, while the other one presented as normal after being removed from the animal. Summarizing, central vein catheterization through the ear vein was feasible in 93.5% and repeated blood sampling was possible in 89.1% of the piglets (n = 46).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Laboratory Animals
Laboratory Animals 生物-动物学
CiteScore
4.90
自引率
8.30%
发文量
64
审稿时长
6-12 weeks
期刊介绍: The international journal of laboratory animal science and welfare, Laboratory Animals publishes peer-reviewed original papers and reviews on all aspects of the use of animals in biomedical research. The journal promotes improvements in the welfare or well-being of the animals used, it particularly focuses on research that reduces the number of animals used or which replaces animal models with in vitro alternatives.
期刊最新文献
Half the price, twice the gain: How to simultaneously decrease animal numbers and increase precision with good experimental design. Heterogeneity of animal experiments and how to deal with it. How cage effects can hurt statistical analyses of completely randomized designs. Simulation methodologies to determine statistical power in laboratory animal research studies. Understanding p-values and significance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1