先进空气净化技术对长期护理机构环境和临床结果的影响。

IF 4.3 2区 医学 Q1 GERIATRICS & GERONTOLOGY Journals of Gerontology Series A-Biological Sciences and Medical Sciences Pub Date : 2023-12-01 DOI:10.1093/gerona/glad113
Alicia R Urrutia, Susan D Schlener, Sherrine Eid, Kelly A Bock, Kathryn C Worrilow
{"title":"先进空气净化技术对长期护理机构环境和临床结果的影响。","authors":"Alicia R Urrutia, Susan D Schlener, Sherrine Eid, Kelly A Bock, Kathryn C Worrilow","doi":"10.1093/gerona/glad113","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Long-term care facilities (LTCFs) are constantly working to reduce sources of infectious pathogens to improve resident care. LTCF residents are particularly susceptible to health care-associated infections (HAIs), many of which originate from the air. An advanced air purification technology (AAPT) was designed to comprehensively remediate volatile organic compounds (VOCs) and all airborne pathogens including all airborne bacteria, fungi, and viruses. The AAPT contains a unique combination of proprietary filter media, high-dose ultraviolet germicidal irradiation, and high-efficiency particulate air (HEPA) filtration.</p><p><strong>Methods: </strong>The AAPT was installed in an LTCF's heating, ventilation, and air-conditioning ductwork and 2 floors were studied: the study floor with comprehensive AAPT remediation and HEPA filtration and the control floor with only HEPA filtration. VOC loading and airborne and surface pathogen loading were measured in 5 locations on both floors. Clinical metrics such as HAI rates were also studied.</p><p><strong>Results: </strong>There was a statistically significant 98.83% reduction in airborne pathogens, which are responsible for illness and infection, an 89.88% reduction in VOCs, and a 39.6% reduction in HAIs. Surface pathogen loading was reduced in all locations except 1 resident room where the detected pathogens were linked to direct touch.</p><p><strong>Conclusions: </strong>The removal of airborne and surface pathogens by the AAPT led to a dramatic reduction in HAIs. The comprehensive removal of airborne contaminants has a direct positive impact on resident wellness and quality of life. It is critical that LTCFs incorporate aggressive airborne purification methods with their current infection control protocols.</p>","PeriodicalId":49953,"journal":{"name":"Journals of Gerontology Series A-Biological Sciences and Medical Sciences","volume":" ","pages":"2325-2332"},"PeriodicalIF":4.3000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10692422/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Effects of an Advanced Air Purification Technology on Environmental and Clinical Outcomes in a Long-Term Care Facility.\",\"authors\":\"Alicia R Urrutia, Susan D Schlener, Sherrine Eid, Kelly A Bock, Kathryn C Worrilow\",\"doi\":\"10.1093/gerona/glad113\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Long-term care facilities (LTCFs) are constantly working to reduce sources of infectious pathogens to improve resident care. LTCF residents are particularly susceptible to health care-associated infections (HAIs), many of which originate from the air. An advanced air purification technology (AAPT) was designed to comprehensively remediate volatile organic compounds (VOCs) and all airborne pathogens including all airborne bacteria, fungi, and viruses. The AAPT contains a unique combination of proprietary filter media, high-dose ultraviolet germicidal irradiation, and high-efficiency particulate air (HEPA) filtration.</p><p><strong>Methods: </strong>The AAPT was installed in an LTCF's heating, ventilation, and air-conditioning ductwork and 2 floors were studied: the study floor with comprehensive AAPT remediation and HEPA filtration and the control floor with only HEPA filtration. VOC loading and airborne and surface pathogen loading were measured in 5 locations on both floors. Clinical metrics such as HAI rates were also studied.</p><p><strong>Results: </strong>There was a statistically significant 98.83% reduction in airborne pathogens, which are responsible for illness and infection, an 89.88% reduction in VOCs, and a 39.6% reduction in HAIs. Surface pathogen loading was reduced in all locations except 1 resident room where the detected pathogens were linked to direct touch.</p><p><strong>Conclusions: </strong>The removal of airborne and surface pathogens by the AAPT led to a dramatic reduction in HAIs. The comprehensive removal of airborne contaminants has a direct positive impact on resident wellness and quality of life. It is critical that LTCFs incorporate aggressive airborne purification methods with their current infection control protocols.</p>\",\"PeriodicalId\":49953,\"journal\":{\"name\":\"Journals of Gerontology Series A-Biological Sciences and Medical Sciences\",\"volume\":\" \",\"pages\":\"2325-2332\"},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10692422/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journals of Gerontology Series A-Biological Sciences and Medical Sciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/gerona/glad113\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"GERIATRICS & GERONTOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journals of Gerontology Series A-Biological Sciences and Medical Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/gerona/glad113","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GERIATRICS & GERONTOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:长期护理机构(ltcf)一直在努力减少传染性病原体的来源,以改善住院病人的护理。长期cf居民特别容易受到卫生保健相关感染(HAIs),其中许多来自空气。一种先进的空气净化技术(AAPT)旨在全面修复挥发性有机化合物(VOCs)和所有空气中的病原体,包括所有空气中的细菌、真菌和病毒。AAPT包含专有过滤介质、高剂量紫外线杀菌照射和高效微粒空气(HEPA)过滤的独特组合。方法:将AAPT安装在LTCF的采暖、通风和空调管道中,并对2个楼层进行了研究:研究楼层为AAPT综合修复并进行HEPA过滤的楼层,对照组为仅进行HEPA过滤的楼层。在两层楼的5个地点测量VOC负荷、空气和表面病原体负荷。临床指标,如HAI率也进行了研究。结果:空气中导致疾病和感染的致病菌减少98.83%,VOCs减少89.88%,HAIs减少39.6%,具有统计学意义。除1个居民房间外,所有地点的表面病原体负荷均有所减少,其中检测到的病原体与直接接触有关。结论:AAPT去除空气和表面病原体导致HAIs的显著减少。空气污染物的全面去除对居民的健康和生活质量有直接的积极影响。ltcf将积极的空气净化方法与当前的感染控制方案结合起来是至关重要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Effects of an Advanced Air Purification Technology on Environmental and Clinical Outcomes in a Long-Term Care Facility.

Background: Long-term care facilities (LTCFs) are constantly working to reduce sources of infectious pathogens to improve resident care. LTCF residents are particularly susceptible to health care-associated infections (HAIs), many of which originate from the air. An advanced air purification technology (AAPT) was designed to comprehensively remediate volatile organic compounds (VOCs) and all airborne pathogens including all airborne bacteria, fungi, and viruses. The AAPT contains a unique combination of proprietary filter media, high-dose ultraviolet germicidal irradiation, and high-efficiency particulate air (HEPA) filtration.

Methods: The AAPT was installed in an LTCF's heating, ventilation, and air-conditioning ductwork and 2 floors were studied: the study floor with comprehensive AAPT remediation and HEPA filtration and the control floor with only HEPA filtration. VOC loading and airborne and surface pathogen loading were measured in 5 locations on both floors. Clinical metrics such as HAI rates were also studied.

Results: There was a statistically significant 98.83% reduction in airborne pathogens, which are responsible for illness and infection, an 89.88% reduction in VOCs, and a 39.6% reduction in HAIs. Surface pathogen loading was reduced in all locations except 1 resident room where the detected pathogens were linked to direct touch.

Conclusions: The removal of airborne and surface pathogens by the AAPT led to a dramatic reduction in HAIs. The comprehensive removal of airborne contaminants has a direct positive impact on resident wellness and quality of life. It is critical that LTCFs incorporate aggressive airborne purification methods with their current infection control protocols.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
10.00
自引率
5.90%
发文量
233
审稿时长
3-8 weeks
期刊介绍: Publishes articles representing the full range of medical sciences pertaining to aging. Appropriate areas include, but are not limited to, basic medical science, clinical epidemiology, clinical research, and health services research for professions such as medicine, dentistry, allied health sciences, and nursing. It publishes articles on research pertinent to human biology and disease.
期刊最新文献
Hypoxanthine Induces Signs of Bladder Aging With Voiding Dysfunction and Lower Urinary Tract Remodeling. Skeletal Muscle Health, Physical Performance, and Lower Urinary Tract Symptoms in Older Adults: The Study of Muscle, Mobility, and Aging. Establishment of Baseline Urinary Antimicrobial Peptide Levels by Age: A Prospective Observational Study. First Observations of a Potential Association Between Accumulation of Per- and Polyfluoroalkyl Substances in the Central Nervous System and Markers of Alzheimer's Disease. No Associations Between Glucosamine Supplementation and Dementia or Parkinson's Disease: Findings From a Large Prospective Cohort Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1