Isabella R P Coelho, Cláudia H Silva-Lovato, Carolina N F Arruda, Eliseu A Münchow, Gabriella R C Silveira, Rodrigo F Carvalho, Mauricio M Badaró
{"title":"义齿清洁剂对具有独特光学特性的弹性衬垫的影响。","authors":"Isabella R P Coelho, Cláudia H Silva-Lovato, Carolina N F Arruda, Eliseu A Münchow, Gabriella R C Silveira, Rodrigo F Carvalho, Mauricio M Badaró","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate denture cleansing solutions regarding the surface roughness and color stability of two resilient liners with distinct optical characteristics used for the maximum recommended period of use.</p><p><strong>Methods: </strong>The specimens of each resilient liner, transparent and white, were randomly distributed into groups (n= 15) of a daily 20-minute immersion simulation of 0.25%, 0.5% and 1% sodium hypochlorite (SH) and 4% acetic acid solutions. Surface roughness (Ra) and color stability (ΔE CIELab formula and NBS systems) were measured after 7, 14, 21, 30, 60, 90, 180, and 270 days. The factors of variations analyzed were material, solutions, and time of immersion. Statistical analysis used three-way ANOVA and Tukey tests (Ra), and repeated measure ANOVA (ΔE and NBS systems), P< 0.05.</p><p><strong>Results: </strong>For Ra analysis, the variations occurred regardless of time and solution, as the white liner showed the greatest changes (P< 0.001). Regarding interactions between solution and time, in the period of 21 days until 270 days, Ra was equivalent for all solutions (P= 0.001). ΔE analysis showed a difference between solutions (P= 0.000) and interaction between time and solution (P= 0.000). For the transparent liner, the greatest changes were found for 1% SH after 60 days, however, at 270 days there was a color change equivalence with 0.5% SH, while 4% acetic acid solution showed intermediate values. For the white liner, 1% SH showed the highest color changes for all evaluated times, and the other evaluated solutions were similar after 270 days. For both resilient liners, 0.25% SH showed the smallest changes for the evaluated properties.</p><p><strong>Clinical significance: </strong>The changes found were dependent on the concentration of the solution used, as well as the length of exposure to the solution. In addition, the white resilient liner showed to be less susceptible to color changes. For both resilient liners, 0.25% sodium hypochlorite showed the least changes for the evaluated properties.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":"36 2","pages":"62-68"},"PeriodicalIF":0.9000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Denture cleanser effect on resilient liners with distinct optical characteristics.\",\"authors\":\"Isabella R P Coelho, Cláudia H Silva-Lovato, Carolina N F Arruda, Eliseu A Münchow, Gabriella R C Silveira, Rodrigo F Carvalho, Mauricio M Badaró\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate denture cleansing solutions regarding the surface roughness and color stability of two resilient liners with distinct optical characteristics used for the maximum recommended period of use.</p><p><strong>Methods: </strong>The specimens of each resilient liner, transparent and white, were randomly distributed into groups (n= 15) of a daily 20-minute immersion simulation of 0.25%, 0.5% and 1% sodium hypochlorite (SH) and 4% acetic acid solutions. Surface roughness (Ra) and color stability (ΔE CIELab formula and NBS systems) were measured after 7, 14, 21, 30, 60, 90, 180, and 270 days. The factors of variations analyzed were material, solutions, and time of immersion. Statistical analysis used three-way ANOVA and Tukey tests (Ra), and repeated measure ANOVA (ΔE and NBS systems), P< 0.05.</p><p><strong>Results: </strong>For Ra analysis, the variations occurred regardless of time and solution, as the white liner showed the greatest changes (P< 0.001). Regarding interactions between solution and time, in the period of 21 days until 270 days, Ra was equivalent for all solutions (P= 0.001). ΔE analysis showed a difference between solutions (P= 0.000) and interaction between time and solution (P= 0.000). For the transparent liner, the greatest changes were found for 1% SH after 60 days, however, at 270 days there was a color change equivalence with 0.5% SH, while 4% acetic acid solution showed intermediate values. For the white liner, 1% SH showed the highest color changes for all evaluated times, and the other evaluated solutions were similar after 270 days. For both resilient liners, 0.25% SH showed the smallest changes for the evaluated properties.</p><p><strong>Clinical significance: </strong>The changes found were dependent on the concentration of the solution used, as well as the length of exposure to the solution. In addition, the white resilient liner showed to be less susceptible to color changes. For both resilient liners, 0.25% sodium hypochlorite showed the least changes for the evaluated properties.</p>\",\"PeriodicalId\":7538,\"journal\":{\"name\":\"American journal of dentistry\",\"volume\":\"36 2\",\"pages\":\"62-68\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of dentistry","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
摘要
目的:评估两种具有不同光学特性的弹性衬垫在建议的最长使用期限内的表面粗糙度和颜色稳定性:将透明和白色两种弹性衬垫的试样随机分配到各组(n= 15),每天用 0.25%、0.5% 和 1%次氯酸钠(SH)以及 4% 乙酸溶液进行 20 分钟的浸泡模拟。分别在 7、14、21、30、60、90、180 和 270 天后测量表面粗糙度(Ra)和颜色稳定性(ΔE CIELab 公式和 NBS 系统)。分析的变化因素包括材料、溶液和浸泡时间。统计分析采用三方方差分析和 Tukey 检验(Ra),以及重复测量方差分析(ΔE 和 NBS 系统),P< 0.05:在 Ra 分析中,无论时间和溶液如何变化,白色衬垫的变化都最大(P< 0.001)。关于溶液和时间之间的相互作用,在 21 天至 270 天期间,所有溶液的 Ra 值都相同(P= 0.001)。ΔE分析表明,不同溶液之间存在差异(P= 0.000),时间与溶液之间存在交互作用(P= 0.000)。对于透明衬垫,1% SH 在 60 天后的变化最大,但在 270 天后,0.5% SH 的颜色变化与透明衬垫相当,而 4% 乙酸溶液则显示出中间值。对于白色衬垫,在所有评估时间内,1% SH 的颜色变化最大,而其他评估溶液在 270 天后的颜色变化相近。对于两种弹性衬垫来说,0.25% 的 SH 在所有评估特性中显示出的变化最小:临床意义:所发现的变化取决于所用溶液的浓度以及接触溶液的时间长短。此外,白色弹性衬垫不易受颜色变化的影响。对于这两种弹性衬垫,0.25% 的次氯酸钠对所评估特性的影响最小。
Denture cleanser effect on resilient liners with distinct optical characteristics.
Purpose: To evaluate denture cleansing solutions regarding the surface roughness and color stability of two resilient liners with distinct optical characteristics used for the maximum recommended period of use.
Methods: The specimens of each resilient liner, transparent and white, were randomly distributed into groups (n= 15) of a daily 20-minute immersion simulation of 0.25%, 0.5% and 1% sodium hypochlorite (SH) and 4% acetic acid solutions. Surface roughness (Ra) and color stability (ΔE CIELab formula and NBS systems) were measured after 7, 14, 21, 30, 60, 90, 180, and 270 days. The factors of variations analyzed were material, solutions, and time of immersion. Statistical analysis used three-way ANOVA and Tukey tests (Ra), and repeated measure ANOVA (ΔE and NBS systems), P< 0.05.
Results: For Ra analysis, the variations occurred regardless of time and solution, as the white liner showed the greatest changes (P< 0.001). Regarding interactions between solution and time, in the period of 21 days until 270 days, Ra was equivalent for all solutions (P= 0.001). ΔE analysis showed a difference between solutions (P= 0.000) and interaction between time and solution (P= 0.000). For the transparent liner, the greatest changes were found for 1% SH after 60 days, however, at 270 days there was a color change equivalence with 0.5% SH, while 4% acetic acid solution showed intermediate values. For the white liner, 1% SH showed the highest color changes for all evaluated times, and the other evaluated solutions were similar after 270 days. For both resilient liners, 0.25% SH showed the smallest changes for the evaluated properties.
Clinical significance: The changes found were dependent on the concentration of the solution used, as well as the length of exposure to the solution. In addition, the white resilient liner showed to be less susceptible to color changes. For both resilient liners, 0.25% sodium hypochlorite showed the least changes for the evaluated properties.
期刊介绍:
The American Journal of Dentistry, published by Mosher & Linder, Inc., provides peer-reviewed scientific articles with clinical significance for the general dental practitioner.