IV型钛超敏症:罕见还是极少发现?

IF 0.4 4区 医学 Q4 ORTHOPEDICS Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca Pub Date : 2023-01-01
J Voves, O Měrka, K Čabanová, J Janošek, G Bajor
{"title":"IV型钛超敏症:罕见还是极少发现?","authors":"J Voves,&nbsp;O Měrka,&nbsp;K Čabanová,&nbsp;J Janošek,&nbsp;G Bajor","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The presented review aims to summarize the current knowledge of hypersensitivity to titanium - a material widely used in medical applications thanks to its exceptional chemical stability, resistance to corrosion, low specific weight and high strength. The hypersensitivity to metals is usually caused by the Type IV immunopathological reaction. Case reports on allergic reactions to titanium are rare but the actual occurrence can be expected to be much higher, especially due to its problematic detection. Although cutaneous patch tests are widely accepted and used for the diagnosis of hypersensitivity of numerous metals (e.g. Ni), it is notoriously unreliable in case of allergies to titanium, which may be associated with the low percutaneous transport of titanium and its salts. The Lymphocyte Transformation Test has superior sensitivity but it remains mostly unknown among clinicians and there are not many laboratories capable of performing it. This review presents numerous case reports indicating, in combination with the above-mentioned facts, that hypersensitivity to titanium should be considered as a possible cause also in non-specific problems associated with titanium implant failure. Key words: titanium, allergy, patch test, lymphocyte transformation test.</p>","PeriodicalId":6980,"journal":{"name":"Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Type IV Titanium Hypersensitivity: Rare, or Rarely Detected?\",\"authors\":\"J Voves,&nbsp;O Měrka,&nbsp;K Čabanová,&nbsp;J Janošek,&nbsp;G Bajor\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The presented review aims to summarize the current knowledge of hypersensitivity to titanium - a material widely used in medical applications thanks to its exceptional chemical stability, resistance to corrosion, low specific weight and high strength. The hypersensitivity to metals is usually caused by the Type IV immunopathological reaction. Case reports on allergic reactions to titanium are rare but the actual occurrence can be expected to be much higher, especially due to its problematic detection. Although cutaneous patch tests are widely accepted and used for the diagnosis of hypersensitivity of numerous metals (e.g. Ni), it is notoriously unreliable in case of allergies to titanium, which may be associated with the low percutaneous transport of titanium and its salts. The Lymphocyte Transformation Test has superior sensitivity but it remains mostly unknown among clinicians and there are not many laboratories capable of performing it. This review presents numerous case reports indicating, in combination with the above-mentioned facts, that hypersensitivity to titanium should be considered as a possible cause also in non-specific problems associated with titanium implant failure. Key words: titanium, allergy, patch test, lymphocyte transformation test.</p>\",\"PeriodicalId\":6980,\"journal\":{\"name\":\"Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

本综述旨在总结目前对钛超敏反应的认识,钛是一种因其优异的化学稳定性、耐腐蚀性、低比重量和高强度而广泛应用于医疗应用的材料。对金属过敏通常是由IV型免疫病理反应引起的。对钛过敏反应的病例报告很少,但实际发生的情况可以预期要高得多,特别是由于其检测问题。虽然皮肤贴片试验被广泛接受并用于诊断对许多金属(如镍)的过敏,但在对钛过敏的情况下,它是出了名的不可靠,这可能与钛及其盐的低经皮转运有关。淋巴细胞转化试验具有优越的敏感性,但临床医生对其知之甚少,也没有多少实验室有能力进行检测。本文回顾了大量的病例报告,结合上述事实,对钛的过敏也应被认为是与钛种植体失败相关的非特异性问题的可能原因。关键词:钛,过敏,斑贴试验,淋巴细胞转化试验
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Type IV Titanium Hypersensitivity: Rare, or Rarely Detected?

The presented review aims to summarize the current knowledge of hypersensitivity to titanium - a material widely used in medical applications thanks to its exceptional chemical stability, resistance to corrosion, low specific weight and high strength. The hypersensitivity to metals is usually caused by the Type IV immunopathological reaction. Case reports on allergic reactions to titanium are rare but the actual occurrence can be expected to be much higher, especially due to its problematic detection. Although cutaneous patch tests are widely accepted and used for the diagnosis of hypersensitivity of numerous metals (e.g. Ni), it is notoriously unreliable in case of allergies to titanium, which may be associated with the low percutaneous transport of titanium and its salts. The Lymphocyte Transformation Test has superior sensitivity but it remains mostly unknown among clinicians and there are not many laboratories capable of performing it. This review presents numerous case reports indicating, in combination with the above-mentioned facts, that hypersensitivity to titanium should be considered as a possible cause also in non-specific problems associated with titanium implant failure. Key words: titanium, allergy, patch test, lymphocyte transformation test.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.70
自引率
25.00%
发文量
53
期刊介绍: Editorial Board accepts for publication articles, reports from congresses, fellowships, book reviews, reports concerning activities of orthopaedic and other relating specialised societies, reports on anniversaries of outstanding personalities in orthopaedics and announcements of congresses and symposia being prepared. Articles include original papers, case reports and current concepts reviews and recently also instructional lectures.
期刊最新文献
Three-Dimensional Computed Tomography Image Reformation for Comparison of Foraminal Cross-Sectional Dimension in Patients Who Have Undergone Laminoplasty and Laminectomy with Fusion [Acta Chir Orthop Traumatol Cech., 2024;91:103-108] [Arthroscopic Subtalar Distraction Arthrodesis in Post-Traumatic Indications]. [Sagittal Profi le of the Spine in Patients after Lumbar Stabilisation Surgeries]. [Total Hip Arthroplasty Using the AMIS Method: Surgical Technique, Suitability of This Method for Obese Patients, Evaluation of the Study Population]. Management of Length Unstable Femur Fractures in Children by Flexible Intramedullary Nails: A Systematic Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1