你的捕虫器还在用6伏电池吗?

Pub Date : 2023-03-01 DOI:10.2987/22-7061
Robert Ewing, Ben Brokesh, Phillip Shults, Lee W Cohnstaedt
{"title":"你的捕虫器还在用6伏电池吗?","authors":"Robert Ewing,&nbsp;Ben Brokesh,&nbsp;Phillip Shults,&nbsp;Lee W Cohnstaedt","doi":"10.2987/22-7061","DOIUrl":null,"url":null,"abstract":"<p><p>The most prevalent insect sampling and surveillance problem is powering insect traps in the field. Most modern light traps use 6-V power supplies such as the Centers for Disease Control and Prevention (CDC) suction trap. Buck converter modules efficiently reduce 12-V direct current power to 6-V, which permits the use of higher voltage batteries with lower voltage traps, resulting in longer operational duration and reduced labor requirements associated with replacing and recharging batteries in the field. We evaluated several battery configurations of 6- and 12-V lead-acid batteries in various sizes (10-20 ampere-hours) and addressed, in the circuit design, common problems that occur when using the buck converter (such as crossing polarity and excessive battery depletion). The efficacy of each configuration was assessed by measuring the voltage and suction while powering a 6-V CDC light trap. The buck converter permitted the use of cheaper and more commonly available 12-V batteries to run the CDC light traps and resulted in longer effective operation time as measured by air speed.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Are You Still Using 6-Volt Batteries for Your Insect Traps?\",\"authors\":\"Robert Ewing,&nbsp;Ben Brokesh,&nbsp;Phillip Shults,&nbsp;Lee W Cohnstaedt\",\"doi\":\"10.2987/22-7061\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The most prevalent insect sampling and surveillance problem is powering insect traps in the field. Most modern light traps use 6-V power supplies such as the Centers for Disease Control and Prevention (CDC) suction trap. Buck converter modules efficiently reduce 12-V direct current power to 6-V, which permits the use of higher voltage batteries with lower voltage traps, resulting in longer operational duration and reduced labor requirements associated with replacing and recharging batteries in the field. We evaluated several battery configurations of 6- and 12-V lead-acid batteries in various sizes (10-20 ampere-hours) and addressed, in the circuit design, common problems that occur when using the buck converter (such as crossing polarity and excessive battery depletion). The efficacy of each configuration was assessed by measuring the voltage and suction while powering a 6-V CDC light trap. The buck converter permitted the use of cheaper and more commonly available 12-V batteries to run the CDC light traps and resulted in longer effective operation time as measured by air speed.</p>\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.2987/22-7061\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.2987/22-7061","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

最普遍的昆虫采样和监测问题是为田间昆虫陷阱供电。大多数现代捕光器使用6v电源,如疾病控制和预防中心(CDC)的吸力捕光器。Buck转换器模块有效地将12 v直流功率降低到6 v,从而允许使用具有较低电压陷阱的更高电压电池,从而延长工作时间,并减少与现场更换和充电电池相关的劳动力需求。我们评估了不同尺寸(10-20安培小时)的6 v和12 v铅酸电池的几种电池配置,并在电路设计中解决了使用降压转换器时出现的常见问题(例如极性交叉和电池过度耗尽)。在为6v CDC光阱供电时,通过测量电压和吸力来评估每种配置的有效性。buck转换器允许使用更便宜和更常见的12v电池来运行CDC光阱,并通过空气速度测量产生更长的有效操作时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
Are You Still Using 6-Volt Batteries for Your Insect Traps?

The most prevalent insect sampling and surveillance problem is powering insect traps in the field. Most modern light traps use 6-V power supplies such as the Centers for Disease Control and Prevention (CDC) suction trap. Buck converter modules efficiently reduce 12-V direct current power to 6-V, which permits the use of higher voltage batteries with lower voltage traps, resulting in longer operational duration and reduced labor requirements associated with replacing and recharging batteries in the field. We evaluated several battery configurations of 6- and 12-V lead-acid batteries in various sizes (10-20 ampere-hours) and addressed, in the circuit design, common problems that occur when using the buck converter (such as crossing polarity and excessive battery depletion). The efficacy of each configuration was assessed by measuring the voltage and suction while powering a 6-V CDC light trap. The buck converter permitted the use of cheaper and more commonly available 12-V batteries to run the CDC light traps and resulted in longer effective operation time as measured by air speed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1