{"title":"三维打印技术在股骨颈骨折术后骨不连治疗中的应用1例。","authors":"Baozhe Liu, Hailun Gu, Yafeng Liu","doi":"10.5152/j.aott.2023.21405","DOIUrl":null,"url":null,"abstract":"<p><p>Nonunion of the femoral neck represents the main complication following fractures at this location. Few studies have documented the application of 3-dimensional printing technology for the surgical treatment of postoperative nonunion of femoral neck fractures. The present manuscript describes a case of a particular 3-dimensional printing technology method for designing a custom-made guide plate for revision surgery. A 46-year-old man suffered a nonunion of the femoral neck following an internal fracture fixation. Using 3-dimensional printing technology, we preoperatively printed a femur model and a custom-made guide plate. Using the model, we performed a simulated operation before the surgery, and the guide plate was used for accurate osteotomy during the operation. With this method, we achieved the desired results: the fracture healed, the operation time was shortened, and there was no femoral head necrosis. Our case suggests that 3-dimensional printing technology provides an effective aid in the treatment of patients with nonunion following a femoral neck fracture and recommends 3-dimensional printing technology for such cases.</p>","PeriodicalId":7097,"journal":{"name":"Acta orthopaedica et traumatologica turcica","volume":"57 2","pages":"78-84"},"PeriodicalIF":1.1000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of 3-dimensional printing technology in the treatment of postoperative nonunion of femoral neck fracture: A case report.\",\"authors\":\"Baozhe Liu, Hailun Gu, Yafeng Liu\",\"doi\":\"10.5152/j.aott.2023.21405\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Nonunion of the femoral neck represents the main complication following fractures at this location. Few studies have documented the application of 3-dimensional printing technology for the surgical treatment of postoperative nonunion of femoral neck fractures. The present manuscript describes a case of a particular 3-dimensional printing technology method for designing a custom-made guide plate for revision surgery. A 46-year-old man suffered a nonunion of the femoral neck following an internal fracture fixation. Using 3-dimensional printing technology, we preoperatively printed a femur model and a custom-made guide plate. Using the model, we performed a simulated operation before the surgery, and the guide plate was used for accurate osteotomy during the operation. With this method, we achieved the desired results: the fracture healed, the operation time was shortened, and there was no femoral head necrosis. Our case suggests that 3-dimensional printing technology provides an effective aid in the treatment of patients with nonunion following a femoral neck fracture and recommends 3-dimensional printing technology for such cases.</p>\",\"PeriodicalId\":7097,\"journal\":{\"name\":\"Acta orthopaedica et traumatologica turcica\",\"volume\":\"57 2\",\"pages\":\"78-84\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta orthopaedica et traumatologica turcica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5152/j.aott.2023.21405\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica et traumatologica turcica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5152/j.aott.2023.21405","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Application of 3-dimensional printing technology in the treatment of postoperative nonunion of femoral neck fracture: A case report.
Nonunion of the femoral neck represents the main complication following fractures at this location. Few studies have documented the application of 3-dimensional printing technology for the surgical treatment of postoperative nonunion of femoral neck fractures. The present manuscript describes a case of a particular 3-dimensional printing technology method for designing a custom-made guide plate for revision surgery. A 46-year-old man suffered a nonunion of the femoral neck following an internal fracture fixation. Using 3-dimensional printing technology, we preoperatively printed a femur model and a custom-made guide plate. Using the model, we performed a simulated operation before the surgery, and the guide plate was used for accurate osteotomy during the operation. With this method, we achieved the desired results: the fracture healed, the operation time was shortened, and there was no femoral head necrosis. Our case suggests that 3-dimensional printing technology provides an effective aid in the treatment of patients with nonunion following a femoral neck fracture and recommends 3-dimensional printing technology for such cases.
期刊介绍:
Acta Orthopaedica et Traumatologica Turcica (AOTT) is an international, scientific, open access periodical published in accordance with independent, unbiased, and double-blinded peer-review principles. The journal is the official publication of the Turkish Association of Orthopaedics and Traumatology, and Turkish Society of Orthopaedics and Traumatology. It is published bimonthly in January, March, May, July, September, and November. The publication language of the journal is English.
The aim of the journal is to publish original studies of the highest scientific and clinical value in orthopedics, traumatology, and related disciplines. The scope of the journal includes but not limited to diagnostic, treatment, and prevention methods related to orthopedics and traumatology. Acta Orthopaedica et Traumatologica Turcica publishes clinical and basic research articles, case reports, personal clinical and technical notes, systematic reviews and meta-analyses and letters to the Editor. Proceedings of scientific meetings are also considered for publication.
The target audience of the journal includes healthcare professionals, physicians, and researchers who are interested or working in orthopedics and traumatology field, and related disciplines.