遥测比格犬、哥廷根迷你猪和食蟹猴非人类灵长类动物自发性心律失常的发生率:HESI联盟回顾性分析

IF 1.3 4区 医学 Q4 PHARMACOLOGY & PHARMACY Journal of pharmacological and toxicological methods Pub Date : 2023-05-01 DOI:10.1016/j.vascn.2023.107266
Emmanuel Boulay , Loïs S. Miraucourt , Michael K. Pugsley , Matthew M. Abernathy , Ray Chui , Jill Dalton , Marjorie Demers , Noel Dybdal , Elissa Gazaille , Andrea Greiter-Wilke , Peter Hoffmann , Hai Huang , Carrie LaDuke , Kevin Norton , Jennifer B. Pierson , Isabelle Reeves , Brian Roche , Eric I. Rossman , Albert E. Schultze , Hai-Ming Tang , Simon Authier
{"title":"遥测比格犬、哥廷根迷你猪和食蟹猴非人类灵长类动物自发性心律失常的发生率:HESI联盟回顾性分析","authors":"Emmanuel Boulay ,&nbsp;Loïs S. Miraucourt ,&nbsp;Michael K. Pugsley ,&nbsp;Matthew M. Abernathy ,&nbsp;Ray Chui ,&nbsp;Jill Dalton ,&nbsp;Marjorie Demers ,&nbsp;Noel Dybdal ,&nbsp;Elissa Gazaille ,&nbsp;Andrea Greiter-Wilke ,&nbsp;Peter Hoffmann ,&nbsp;Hai Huang ,&nbsp;Carrie LaDuke ,&nbsp;Kevin Norton ,&nbsp;Jennifer B. Pierson ,&nbsp;Isabelle Reeves ,&nbsp;Brian Roche ,&nbsp;Eric I. Rossman ,&nbsp;Albert E. Schultze ,&nbsp;Hai-Ming Tang ,&nbsp;Simon Authier","doi":"10.1016/j.vascn.2023.107266","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Characterization of the incidence of spontaneous arrhythmias to identify possible drug-related effects is often an important part of the analysis in safety pharmacology studies using telemetry.</p></div><div><h3>Methods</h3><p>A retrospective analysis in non-clinical species with and without telemetry transmitters was conducted. Electrocardiograms (24 h) from male and female beagle dogs (<em>n</em> = 131), Göttingen minipigs (<em>n</em> = 108) and cynomolgus non-human primates (NHP; <em>n</em> = 78) were analyzed.</p></div><div><h3>Results</h3><p>Ventricular tachycardia (VT) was observed in 3% of the dogs but was absent in minipigs and NHPs. Ventricular fibrillation (VF) was not observed in the 3 species. Ventricular premature beats (VPBs) were more frequent during daytime and atrioventricular blocks (AVBs) were more frequent at night in all species. A limited number of animals exhibited a high arrhythmia frequency and there was no correlation between animals with higher frequency of an arrhythmia type and the frequency of other arrythmias in the same animals. Clinical chemistry or hematology parameters were not different with or without telemetry devices. NHP with a transmural left ventricular pressure (LVP) catheter exhibited a greater incidence of VPBs and PJCs compared to telemetry animals without LVP.</p></div><div><h3>Discussion</h3><p>All species were similar with regards to the frequency of ventricular ectopic beats (26–46%) while the dog seemed to have more frequent junctional complexes and AVB compared to NHP and minipigs. Arrhythmia screening may be considered during pre-study evaluations, to exclude animals with abnormally high arrhythmia incidence.</p></div>","PeriodicalId":16767,"journal":{"name":"Journal of pharmacological and toxicological methods","volume":"121 ","pages":"Article 107266"},"PeriodicalIF":1.3000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The incidence of spontaneous arrhythmias in telemetered beagle dogs, Göttingen Minipigs and Cynomolgus non-human primates: A HESI consortium retrospective analysis\",\"authors\":\"Emmanuel Boulay ,&nbsp;Loïs S. Miraucourt ,&nbsp;Michael K. Pugsley ,&nbsp;Matthew M. Abernathy ,&nbsp;Ray Chui ,&nbsp;Jill Dalton ,&nbsp;Marjorie Demers ,&nbsp;Noel Dybdal ,&nbsp;Elissa Gazaille ,&nbsp;Andrea Greiter-Wilke ,&nbsp;Peter Hoffmann ,&nbsp;Hai Huang ,&nbsp;Carrie LaDuke ,&nbsp;Kevin Norton ,&nbsp;Jennifer B. Pierson ,&nbsp;Isabelle Reeves ,&nbsp;Brian Roche ,&nbsp;Eric I. Rossman ,&nbsp;Albert E. Schultze ,&nbsp;Hai-Ming Tang ,&nbsp;Simon Authier\",\"doi\":\"10.1016/j.vascn.2023.107266\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>Characterization of the incidence of spontaneous arrhythmias to identify possible drug-related effects is often an important part of the analysis in safety pharmacology studies using telemetry.</p></div><div><h3>Methods</h3><p>A retrospective analysis in non-clinical species with and without telemetry transmitters was conducted. Electrocardiograms (24 h) from male and female beagle dogs (<em>n</em> = 131), Göttingen minipigs (<em>n</em> = 108) and cynomolgus non-human primates (NHP; <em>n</em> = 78) were analyzed.</p></div><div><h3>Results</h3><p>Ventricular tachycardia (VT) was observed in 3% of the dogs but was absent in minipigs and NHPs. Ventricular fibrillation (VF) was not observed in the 3 species. Ventricular premature beats (VPBs) were more frequent during daytime and atrioventricular blocks (AVBs) were more frequent at night in all species. A limited number of animals exhibited a high arrhythmia frequency and there was no correlation between animals with higher frequency of an arrhythmia type and the frequency of other arrythmias in the same animals. Clinical chemistry or hematology parameters were not different with or without telemetry devices. NHP with a transmural left ventricular pressure (LVP) catheter exhibited a greater incidence of VPBs and PJCs compared to telemetry animals without LVP.</p></div><div><h3>Discussion</h3><p>All species were similar with regards to the frequency of ventricular ectopic beats (26–46%) while the dog seemed to have more frequent junctional complexes and AVB compared to NHP and minipigs. Arrhythmia screening may be considered during pre-study evaluations, to exclude animals with abnormally high arrhythmia incidence.</p></div>\",\"PeriodicalId\":16767,\"journal\":{\"name\":\"Journal of pharmacological and toxicological methods\",\"volume\":\"121 \",\"pages\":\"Article 107266\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of pharmacological and toxicological methods\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1056871923000175\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of pharmacological and toxicological methods","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1056871923000175","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 1

摘要

引言在使用遥测的安全药理学研究中,表征自发性心律失常的发生率以确定可能的药物相关影响通常是分析的重要组成部分。方法对使用和不使用遥测发射器的非临床物种进行回顾性分析。分析了雄性和雌性比格犬(n=131)、哥廷根小型猪(n=108)和食蟹猴非人类灵长类动物(NHP;n=78)的心电图(24小时)。结果3%的犬出现室性心动过速(VT),但在小型猪和NHP中没有。在3个物种中未观察到心室颤动(VF)。在所有物种中,室性早搏(VPB)在白天更频繁,房室传导阻滞(AVB)在夜间更频繁。数量有限的动物表现出高心律失常频率,心律失常类型频率较高的动物与同一动物中其他心律失常的频率之间没有相关性。无论有无遥测装置,临床化学或血液学参数均无差异。与没有LVP的遥测动物相比,具有透壁左心室压(LVP)导管的NHP表现出更大的VPB和PJC发生率。讨论所有物种的心室异位搏动频率相似(26-46%),而与NHP和小型猪相比,狗似乎有更频繁的交界复合体和AVB。研究前评估期间可考虑进行心律失常筛查,以排除心律失常发生率异常高的动物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The incidence of spontaneous arrhythmias in telemetered beagle dogs, Göttingen Minipigs and Cynomolgus non-human primates: A HESI consortium retrospective analysis

Introduction

Characterization of the incidence of spontaneous arrhythmias to identify possible drug-related effects is often an important part of the analysis in safety pharmacology studies using telemetry.

Methods

A retrospective analysis in non-clinical species with and without telemetry transmitters was conducted. Electrocardiograms (24 h) from male and female beagle dogs (n = 131), Göttingen minipigs (n = 108) and cynomolgus non-human primates (NHP; n = 78) were analyzed.

Results

Ventricular tachycardia (VT) was observed in 3% of the dogs but was absent in minipigs and NHPs. Ventricular fibrillation (VF) was not observed in the 3 species. Ventricular premature beats (VPBs) were more frequent during daytime and atrioventricular blocks (AVBs) were more frequent at night in all species. A limited number of animals exhibited a high arrhythmia frequency and there was no correlation between animals with higher frequency of an arrhythmia type and the frequency of other arrythmias in the same animals. Clinical chemistry or hematology parameters were not different with or without telemetry devices. NHP with a transmural left ventricular pressure (LVP) catheter exhibited a greater incidence of VPBs and PJCs compared to telemetry animals without LVP.

Discussion

All species were similar with regards to the frequency of ventricular ectopic beats (26–46%) while the dog seemed to have more frequent junctional complexes and AVB compared to NHP and minipigs. Arrhythmia screening may be considered during pre-study evaluations, to exclude animals with abnormally high arrhythmia incidence.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of pharmacological and toxicological methods
Journal of pharmacological and toxicological methods PHARMACOLOGY & PHARMACY-TOXICOLOGY
CiteScore
3.60
自引率
10.50%
发文量
56
审稿时长
26 days
期刊介绍: Journal of Pharmacological and Toxicological Methods publishes original articles on current methods of investigation used in pharmacology and toxicology. Pharmacology and toxicology are defined in the broadest sense, referring to actions of drugs and chemicals on all living systems. With its international editorial board and noted contributors, Journal of Pharmacological and Toxicological Methods is the leading journal devoted exclusively to experimental procedures used by pharmacologists and toxicologists.
期刊最新文献
Molecular imaging of excitability difference between alkaloids/salts (nicotine, nicotinic benzoate, caffeine and arecoline hydrobromide) In-situ polyherbal gel as biomedicine in the management of Alzheimer's disease: Understanding ameliorative potential in Trimethyltin induced neurodegeneration Evaluation of 4 quantification methods for monitoring 16 antidepressant drugs and their metabolites in human plasma by LC-MS/MS Comparative toxicity assessment of selected nanoparticles using different experimental model organisms Evaluating the proarrhythmic risk of delayed-action compounds in serum free cell culture conditions; serum-starvation accelerates/amplifies the effect of probucol on the KCNQ1 + KCNE1 channel
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1