以上消化道内镜检查为金标准的肝硬化患者食管静脉曲张分级的计算机断层虚拟食管造影:一项诊断验证研究

IF 0.9 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Polish Journal of Radiology Pub Date : 2023-01-01 DOI:10.5114/pjr.2023.126459
Ravinandan Kumar, Khanak K Nandolia, Pankaj Sharma, Ajeet Singh Bhadoria, Udit Chauhan, Itish Patnaik, Sudhir Saxena
{"title":"以上消化道内镜检查为金标准的肝硬化患者食管静脉曲张分级的计算机断层虚拟食管造影:一项诊断验证研究","authors":"Ravinandan Kumar,&nbsp;Khanak K Nandolia,&nbsp;Pankaj Sharma,&nbsp;Ajeet Singh Bhadoria,&nbsp;Udit Chauhan,&nbsp;Itish Patnaik,&nbsp;Sudhir Saxena","doi":"10.5114/pjr.2023.126459","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Virtual endoscopy is a postprocessing method using three-dimensional computed tomography (CT), which produces views of the inner surfaces of the human body like those produced by fibreoptic endoscopy. To evaluate and categorise patients who require medical or endoscopic band ligation to prevent oesophageal variceal bleed, a less invasive, less expensive, better tolerated, and more sensitive modality is required, as well as to reduce the use of invasive procedures in the follow-up of patients who do not require endoscopic variceal band ligation.</p><p><strong>Material and methods: </strong>A cross-sectional study was conducted in the Department of Radiodiagnosis in association with the Department of Gastroenterology. The study was conducted over a period of 18 months from July 2020 to January 2022. The sample size was calculated as 62 patients. Patients were recruited on the basis of inclusion and exclusion criteria after giving informed consent. CT virtual endoscopy was performed through a dedicated protocol. Classification of variceal grading was done independently by a radiologist and endoscopist who were blinded to each other's findings.</p><p><strong>Results: </strong>The diagnostic performance of oesophageal varices detection by CT virtual oesophagography was good, with sensitivity: 86%, specificity: 90%, PPV: 98%, NPV: 56%, and diagnostic accuracy: 87%. There was substantial agreement between the 2 methods, and this agreement was statistically significant (Cohen's k = 0.616, <i>p</i> ≤ 0.001).</p><p><strong>Conclusions: </strong>Based on our findings, we conclude that the current study has the potential to change the way chronic liver disease is managed, as well as generate similar medical research endeavours. A multicentric study with a large number of patients is needed to improve the experience with this modality.</p>","PeriodicalId":47128,"journal":{"name":"Polish Journal of Radiology","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/6a/08/PJR-88-50510.PMC10207316.pdf","citationCount":"0","resultStr":"{\"title\":\"Computed tomography virtual oesophagography for the grading of oesophageal varices in cirrhotic liver disease patients with upper gastrointestinal endoscopic examination as the gold standard: a diagnostic validation study.\",\"authors\":\"Ravinandan Kumar,&nbsp;Khanak K Nandolia,&nbsp;Pankaj Sharma,&nbsp;Ajeet Singh Bhadoria,&nbsp;Udit Chauhan,&nbsp;Itish Patnaik,&nbsp;Sudhir Saxena\",\"doi\":\"10.5114/pjr.2023.126459\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Virtual endoscopy is a postprocessing method using three-dimensional computed tomography (CT), which produces views of the inner surfaces of the human body like those produced by fibreoptic endoscopy. To evaluate and categorise patients who require medical or endoscopic band ligation to prevent oesophageal variceal bleed, a less invasive, less expensive, better tolerated, and more sensitive modality is required, as well as to reduce the use of invasive procedures in the follow-up of patients who do not require endoscopic variceal band ligation.</p><p><strong>Material and methods: </strong>A cross-sectional study was conducted in the Department of Radiodiagnosis in association with the Department of Gastroenterology. The study was conducted over a period of 18 months from July 2020 to January 2022. The sample size was calculated as 62 patients. Patients were recruited on the basis of inclusion and exclusion criteria after giving informed consent. CT virtual endoscopy was performed through a dedicated protocol. Classification of variceal grading was done independently by a radiologist and endoscopist who were blinded to each other's findings.</p><p><strong>Results: </strong>The diagnostic performance of oesophageal varices detection by CT virtual oesophagography was good, with sensitivity: 86%, specificity: 90%, PPV: 98%, NPV: 56%, and diagnostic accuracy: 87%. There was substantial agreement between the 2 methods, and this agreement was statistically significant (Cohen's k = 0.616, <i>p</i> ≤ 0.001).</p><p><strong>Conclusions: </strong>Based on our findings, we conclude that the current study has the potential to change the way chronic liver disease is managed, as well as generate similar medical research endeavours. A multicentric study with a large number of patients is needed to improve the experience with this modality.</p>\",\"PeriodicalId\":47128,\"journal\":{\"name\":\"Polish Journal of Radiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/6a/08/PJR-88-50510.PMC10207316.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polish Journal of Radiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5114/pjr.2023.126459\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/pjr.2023.126459","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:虚拟内窥镜是一种使用三维计算机断层扫描(CT)的后处理方法,它产生人体内表面的视图,就像纤维内窥镜产生的视图一样。为了评估和分类需要药物或内窥镜绑扎术以预防食管静脉曲张出血的患者,需要一种侵入性更小、成本更低、耐受性更好、更敏感的方式,并减少在不需要内窥镜静脉曲张绑扎术的患者的随访中使用侵入性手术。材料和方法:在放射诊断科和消化内科联合进行了一项横断面研究。该研究从2020年7月到2022年1月进行了18个月。计算样本量为62例。在给予知情同意后,根据纳入和排除标准招募患者。通过专用方案进行CT虚拟内窥镜检查。静脉曲张分级的分类是由放射科医生和内窥镜医生独立完成的,他们对彼此的发现一无所知。结果:CT虚拟食管造影检测食管静脉曲张的诊断性能良好,敏感性为86%,特异性为90%,PPV为98%,NPV为56%,诊断准确率为87%。两种方法的结果基本一致,且具有统计学意义(Cohen’s k = 0.616, p≤0.001)。结论:基于我们的发现,我们得出结论,当前的研究有可能改变慢性肝病的治疗方式,并产生类似的医学研究成果。需要对大量患者进行多中心研究来改善这种模式的体验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Computed tomography virtual oesophagography for the grading of oesophageal varices in cirrhotic liver disease patients with upper gastrointestinal endoscopic examination as the gold standard: a diagnostic validation study.

Purpose: Virtual endoscopy is a postprocessing method using three-dimensional computed tomography (CT), which produces views of the inner surfaces of the human body like those produced by fibreoptic endoscopy. To evaluate and categorise patients who require medical or endoscopic band ligation to prevent oesophageal variceal bleed, a less invasive, less expensive, better tolerated, and more sensitive modality is required, as well as to reduce the use of invasive procedures in the follow-up of patients who do not require endoscopic variceal band ligation.

Material and methods: A cross-sectional study was conducted in the Department of Radiodiagnosis in association with the Department of Gastroenterology. The study was conducted over a period of 18 months from July 2020 to January 2022. The sample size was calculated as 62 patients. Patients were recruited on the basis of inclusion and exclusion criteria after giving informed consent. CT virtual endoscopy was performed through a dedicated protocol. Classification of variceal grading was done independently by a radiologist and endoscopist who were blinded to each other's findings.

Results: The diagnostic performance of oesophageal varices detection by CT virtual oesophagography was good, with sensitivity: 86%, specificity: 90%, PPV: 98%, NPV: 56%, and diagnostic accuracy: 87%. There was substantial agreement between the 2 methods, and this agreement was statistically significant (Cohen's k = 0.616, p ≤ 0.001).

Conclusions: Based on our findings, we conclude that the current study has the potential to change the way chronic liver disease is managed, as well as generate similar medical research endeavours. A multicentric study with a large number of patients is needed to improve the experience with this modality.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Polish Journal of Radiology
Polish Journal of Radiology RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
2.10
自引率
0.00%
发文量
0
期刊最新文献
Lung ultrasound in a nutshell. Lines, signs, some applications, and misconceptions from a radiologist's point of view. Ablation of pulmonary neoplasms: review of literature and future perspectives. Bone marrow lesions of the femoral head: can radiomics distinguish whether it is reversible? Summary of radiation dose management and optimization: comparison of radiation protection measures between Poland and other countries. Diagnosis and treatment of peritoneal carcinomatosis - a comprehensive overview.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1