新型液体型快速脲酶检测试剂盒(Helicotest®)的开发:与其他商用试剂盒的比较。

IF 0.6 Q4 GASTROENTEROLOGY & HEPATOLOGY The Korean journal of gastroenterology = Taehan Sohwagi Hakhoe chi Pub Date : 2023-05-25 DOI:10.4166/kjg.2022.139
Hannah Lee, Hyo Sang Hwang, Jun-Won Chung, Kyeong Ah Kim, Seon Tae Kim
{"title":"新型液体型快速脲酶检测试剂盒(Helicotest®)的开发:与其他商用试剂盒的比较。","authors":"Hannah Lee,&nbsp;Hyo Sang Hwang,&nbsp;Jun-Won Chung,&nbsp;Kyeong Ah Kim,&nbsp;Seon Tae Kim","doi":"10.4166/kjg.2022.139","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aims: </strong>A quick and accurate diagnosis of <i>Helicobacter pylori</i> (<i>H. pylori</i>) infections is vital for effectively managing many upper gastrointestinal tract diseases. Many diagnostic methods have been developed for rapid and accurate diagnosis, including invasive and non-invasive methods, but each tool has some limitations. Among the invasive diagnostic methods, the rapid urease test (RUT) is a relatively time-saving and accurate method, but a variation in the reaction time range causes inconvenience and inefficiency in the clinical field. This study developed a liquid-type medium, Helicotest<sup>®</sup>, to enable faster detection. This study examined the reaction time of a new liquid-type RUT kit with other commercial kits.</p><p><strong>Methods: </strong>Two <i>H. pylori</i> strains were cultured (<i>H. pylori</i> ATCC 700392 and 43504), and the urease activity of <i>H. pylori</i> was measured using a urease activity assay kit (MAK120, Sigma Aldrich). Four RUT kits were used to compare the time of <i>H. pylori</i> detection, including Helicotest<sup>®</sup> (Won Medical, Bucheon, Korea), Hp kit (Chong Kun Dang, Seoul, Korea), CLO kit (Halyard, Alpharetta, GA, USA), and ASAN Helicobacter Test<sup>®</sup> (ASAN, Seoul, Korea).</p><p><strong>Results: </strong>The detection of <i>H. pylori</i> was possible in bacterial amounts less than 10 μL. The color change was detected from five minutes with bacterial densities of 5 μL and 10 μL for both strains, whereas 30 minutes and one hour were required for 0.5 μL and a 1 μL bacterial density of ATCC 43504 and 700392 strains, respectively.</p><p><strong>Conclusions: </strong>Compared to other RUT kits, Helicotest<sup>®</sup> showed the fastest reaction. Therefore, faster diagnosis in clinical practice is expected.</p>","PeriodicalId":22736,"journal":{"name":"The Korean journal of gastroenterology = Taehan Sohwagi Hakhoe chi","volume":"81 5","pages":"209-215"},"PeriodicalIF":0.6000,"publicationDate":"2023-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development of a New Liquid Type Rapid Urease Test Kit (Helicotest<sup>®</sup>): Comparison with Other Commercial Kits.\",\"authors\":\"Hannah Lee,&nbsp;Hyo Sang Hwang,&nbsp;Jun-Won Chung,&nbsp;Kyeong Ah Kim,&nbsp;Seon Tae Kim\",\"doi\":\"10.4166/kjg.2022.139\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background/aims: </strong>A quick and accurate diagnosis of <i>Helicobacter pylori</i> (<i>H. pylori</i>) infections is vital for effectively managing many upper gastrointestinal tract diseases. Many diagnostic methods have been developed for rapid and accurate diagnosis, including invasive and non-invasive methods, but each tool has some limitations. Among the invasive diagnostic methods, the rapid urease test (RUT) is a relatively time-saving and accurate method, but a variation in the reaction time range causes inconvenience and inefficiency in the clinical field. This study developed a liquid-type medium, Helicotest<sup>®</sup>, to enable faster detection. This study examined the reaction time of a new liquid-type RUT kit with other commercial kits.</p><p><strong>Methods: </strong>Two <i>H. pylori</i> strains were cultured (<i>H. pylori</i> ATCC 700392 and 43504), and the urease activity of <i>H. pylori</i> was measured using a urease activity assay kit (MAK120, Sigma Aldrich). Four RUT kits were used to compare the time of <i>H. pylori</i> detection, including Helicotest<sup>®</sup> (Won Medical, Bucheon, Korea), Hp kit (Chong Kun Dang, Seoul, Korea), CLO kit (Halyard, Alpharetta, GA, USA), and ASAN Helicobacter Test<sup>®</sup> (ASAN, Seoul, Korea).</p><p><strong>Results: </strong>The detection of <i>H. pylori</i> was possible in bacterial amounts less than 10 μL. The color change was detected from five minutes with bacterial densities of 5 μL and 10 μL for both strains, whereas 30 minutes and one hour were required for 0.5 μL and a 1 μL bacterial density of ATCC 43504 and 700392 strains, respectively.</p><p><strong>Conclusions: </strong>Compared to other RUT kits, Helicotest<sup>®</sup> showed the fastest reaction. Therefore, faster diagnosis in clinical practice is expected.</p>\",\"PeriodicalId\":22736,\"journal\":{\"name\":\"The Korean journal of gastroenterology = Taehan Sohwagi Hakhoe chi\",\"volume\":\"81 5\",\"pages\":\"209-215\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-05-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Korean journal of gastroenterology = Taehan Sohwagi Hakhoe chi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4166/kjg.2022.139\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Korean journal of gastroenterology = Taehan Sohwagi Hakhoe chi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4166/kjg.2022.139","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 1

摘要

背景/目的:快速准确诊断幽门螺杆菌感染对于有效治疗许多上胃肠道疾病至关重要。为了快速准确的诊断,已经开发了许多诊断方法,包括侵入性和非侵入性方法,但每种工具都有一定的局限性。在侵入性诊断方法中,快速脲酶试验(rapid urease test, RUT)是一种较为省时、准确的方法,但反应时间范围的变化给临床带来了不便和低效率。本研究开发了一种液体型介质Helicotest®,以实现更快的检测。本研究考察了新型液体型RUT试剂盒与其他商用试剂盒的反应时间。方法:培养两株幽门螺杆菌(h.p ylori ATCC 700392和43504),采用Sigma Aldrich公司的MAK120脲酶活性测定试剂盒检测幽门螺杆菌脲酶活性。使用4种RUT试剂盒比较幽门螺杆菌检测时间,包括Helicotest®(韩国富川Won Medical)、Hp kit(韩国首尔Chong Kun Dang)、CLO kit (Halyard, Alpharetta, GA, USA)和ASAN Helicobacter Test®(ASAN,韩国首尔)。结果:在细菌量小于10 μL时可检出幽门螺杆菌。细菌密度分别为5 μL和10 μL时,两株菌株的颜色变化时间为5 min,而细菌密度分别为0.5 μL和1 μL时,ATCC 43504和700392菌株的颜色变化时间分别为30 min和1 h。结论:与其他RUT试剂盒相比,Helicotest®反应速度最快。因此,期望在临床实践中更快地诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of a New Liquid Type Rapid Urease Test Kit (Helicotest®): Comparison with Other Commercial Kits.

Background/aims: A quick and accurate diagnosis of Helicobacter pylori (H. pylori) infections is vital for effectively managing many upper gastrointestinal tract diseases. Many diagnostic methods have been developed for rapid and accurate diagnosis, including invasive and non-invasive methods, but each tool has some limitations. Among the invasive diagnostic methods, the rapid urease test (RUT) is a relatively time-saving and accurate method, but a variation in the reaction time range causes inconvenience and inefficiency in the clinical field. This study developed a liquid-type medium, Helicotest®, to enable faster detection. This study examined the reaction time of a new liquid-type RUT kit with other commercial kits.

Methods: Two H. pylori strains were cultured (H. pylori ATCC 700392 and 43504), and the urease activity of H. pylori was measured using a urease activity assay kit (MAK120, Sigma Aldrich). Four RUT kits were used to compare the time of H. pylori detection, including Helicotest® (Won Medical, Bucheon, Korea), Hp kit (Chong Kun Dang, Seoul, Korea), CLO kit (Halyard, Alpharetta, GA, USA), and ASAN Helicobacter Test® (ASAN, Seoul, Korea).

Results: The detection of H. pylori was possible in bacterial amounts less than 10 μL. The color change was detected from five minutes with bacterial densities of 5 μL and 10 μL for both strains, whereas 30 minutes and one hour were required for 0.5 μL and a 1 μL bacterial density of ATCC 43504 and 700392 strains, respectively.

Conclusions: Compared to other RUT kits, Helicotest® showed the fastest reaction. Therefore, faster diagnosis in clinical practice is expected.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.20
自引率
0.00%
发文量
83
审稿时长
24 weeks
期刊最新文献
Comparison of the Efficacy of 12-day Concomitant Quadruple Therapy versus 14-day High dose Dual Therapy as a First-line H. pylori Eradication Regimen. Association between Atherosclerosis and High-Risk Colorectal Adenomas based on Cardio-Ankle Vascular Index and Ankle-Brachial Index. A Case of Esophageal MALT Lymphoma Mimicking a Subepithelial Tumor. Metastatic Melanoma of the Common Bile Duct Presented with Dyspepsia. Successful Transcatheter Arterial Embolization of Abdominal Wall Hematoma from the Left Deep Circumflex Iliac Artery after Abdominal Paracentesis in a Patient with Liver Cirrhosis: Case Report and Literature Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1