氯化铝止血剂对通用胶粘剂牙本质剪切结合强度的影响。

Sujin Kim, Yoorina Choi, Sujung Park
{"title":"氯化铝止血剂对通用胶粘剂牙本质剪切结合强度的影响。","authors":"Sujin Kim,&nbsp;Yoorina Choi,&nbsp;Sujung Park","doi":"10.5395/rde.2023.48.e14","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study investigated the effect of an aluminum chloride hemostatic agent on the shear bond strength (SBS) of a universal adhesive to dentin.</p><p><strong>Materials and methods: </strong>Eighty extracted human molars were trimmed at the occlusal dentin surfaces and divided mesiodistally. According to hemostatic agent application, specimens were randomly allocated into control (C) and hemostatic agent (Traxodent; H) groups. Each group was divided into 4 subgroups according to the adhesive system (<i>n</i> = 20): Scotchbond Multi-Purpose (SBER), Clearfil SE Bond (CLSE), All-Bond Universal etch-and-rinse mode (ALER), and All-Bond Universal self-etch mode (ALSE). SBS was measured for half of the specimens at 24 hours, and the other half were thermocycled in water baths (group T). Fracture surfaces were examined to determine the failure mode. The SBS was measured, and data were analyzed using 1-way analysis of variance, the Student's <i>t</i>-test, and the Tukey honestly significant difference test (<i>p</i> = 0.05).</p><p><strong>Results: </strong>No significant differences in SBS were found between groups C and H for any adhesive system at 24 hours. After thermocycling, a statistically significant difference was observed between CT+ALSE and HT+ALSE (<i>p</i> < 0.05). When All-Bond Universal was applied to hemostatic agent-contaminated dentin, the SBS of H+ALSE was significantly lower than that of H+ALER (<i>p</i> < 0.05). The SBER subgroups showed no significant differences in SBS regardless of treatment and thermocycling.</p><p><strong>Conclusions: </strong>When exposed dentin was contaminated by an aluminum chloride hemostatic agent before dentin adhesive treatment, application of All-Bond Universal in etch-and-rinse mode was superior to self-etch mode.</p>","PeriodicalId":21102,"journal":{"name":"Restorative Dentistry & Endodontics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/6d/dd/rde-48-e14.PMC10240091.pdf","citationCount":"0","resultStr":"{\"title\":\"Effect of an aluminum chloride hemostatic agent on the dentin shear bond strength of a universal adhesive.\",\"authors\":\"Sujin Kim,&nbsp;Yoorina Choi,&nbsp;Sujung Park\",\"doi\":\"10.5395/rde.2023.48.e14\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>This study investigated the effect of an aluminum chloride hemostatic agent on the shear bond strength (SBS) of a universal adhesive to dentin.</p><p><strong>Materials and methods: </strong>Eighty extracted human molars were trimmed at the occlusal dentin surfaces and divided mesiodistally. According to hemostatic agent application, specimens were randomly allocated into control (C) and hemostatic agent (Traxodent; H) groups. Each group was divided into 4 subgroups according to the adhesive system (<i>n</i> = 20): Scotchbond Multi-Purpose (SBER), Clearfil SE Bond (CLSE), All-Bond Universal etch-and-rinse mode (ALER), and All-Bond Universal self-etch mode (ALSE). SBS was measured for half of the specimens at 24 hours, and the other half were thermocycled in water baths (group T). Fracture surfaces were examined to determine the failure mode. The SBS was measured, and data were analyzed using 1-way analysis of variance, the Student's <i>t</i>-test, and the Tukey honestly significant difference test (<i>p</i> = 0.05).</p><p><strong>Results: </strong>No significant differences in SBS were found between groups C and H for any adhesive system at 24 hours. After thermocycling, a statistically significant difference was observed between CT+ALSE and HT+ALSE (<i>p</i> < 0.05). When All-Bond Universal was applied to hemostatic agent-contaminated dentin, the SBS of H+ALSE was significantly lower than that of H+ALER (<i>p</i> < 0.05). The SBER subgroups showed no significant differences in SBS regardless of treatment and thermocycling.</p><p><strong>Conclusions: </strong>When exposed dentin was contaminated by an aluminum chloride hemostatic agent before dentin adhesive treatment, application of All-Bond Universal in etch-and-rinse mode was superior to self-etch mode.</p>\",\"PeriodicalId\":21102,\"journal\":{\"name\":\"Restorative Dentistry & Endodontics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/6d/dd/rde-48-e14.PMC10240091.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Restorative Dentistry & Endodontics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5395/rde.2023.48.e14\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Restorative Dentistry & Endodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5395/rde.2023.48.e14","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究氯化铝止血剂对牙本质万能粘接剂剪切结合强度(SBS)的影响。材料与方法:80颗拔除的人磨牙在咬合牙本质表面进行修整,并中向分离。根据止血药物的使用情况,将标本随机分为对照组(C)和止血药物组(曲索妥;H)组。每组按粘接系统分为4个亚组(n = 20): Scotchbond Multi-Purpose (SBER), Clearfil SE Bond (CLSE), All-Bond通用蚀刻-漂洗模式(ALER), All-Bond通用自蚀刻模式(ALSE)。其中一半试样在24小时时进行SBS测量,另一半试样在水浴中进行热循环(T组)。对断口表面进行检查以确定破坏模式。测量SBS,数据分析采用单因素方差分析、Student’st检验和Tukey诚实显著性差异检验(p = 0.05)。结果:任何黏附系统在24小时内,C组和H组的SBS均无显著差异。热循环后,CT+ALSE与HT+ALSE比较,差异有统计学意义(p < 0.05)。当All-Bond Universal应用于受止血剂污染的牙本质时,H+ALSE的SBS显著低于H+ALER (p < 0.05)。无论治疗和热循环如何,SBER亚组在SBS方面没有显着差异。结论:在牙本质粘接剂治疗前,当暴露的牙本质被氯化铝止血剂污染时,在蚀刻-冲洗模式下应用All-Bond Universal优于自蚀刻模式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of an aluminum chloride hemostatic agent on the dentin shear bond strength of a universal adhesive.

Objectives: This study investigated the effect of an aluminum chloride hemostatic agent on the shear bond strength (SBS) of a universal adhesive to dentin.

Materials and methods: Eighty extracted human molars were trimmed at the occlusal dentin surfaces and divided mesiodistally. According to hemostatic agent application, specimens were randomly allocated into control (C) and hemostatic agent (Traxodent; H) groups. Each group was divided into 4 subgroups according to the adhesive system (n = 20): Scotchbond Multi-Purpose (SBER), Clearfil SE Bond (CLSE), All-Bond Universal etch-and-rinse mode (ALER), and All-Bond Universal self-etch mode (ALSE). SBS was measured for half of the specimens at 24 hours, and the other half were thermocycled in water baths (group T). Fracture surfaces were examined to determine the failure mode. The SBS was measured, and data were analyzed using 1-way analysis of variance, the Student's t-test, and the Tukey honestly significant difference test (p = 0.05).

Results: No significant differences in SBS were found between groups C and H for any adhesive system at 24 hours. After thermocycling, a statistically significant difference was observed between CT+ALSE and HT+ALSE (p < 0.05). When All-Bond Universal was applied to hemostatic agent-contaminated dentin, the SBS of H+ALSE was significantly lower than that of H+ALER (p < 0.05). The SBER subgroups showed no significant differences in SBS regardless of treatment and thermocycling.

Conclusions: When exposed dentin was contaminated by an aluminum chloride hemostatic agent before dentin adhesive treatment, application of All-Bond Universal in etch-and-rinse mode was superior to self-etch mode.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.20
自引率
0.00%
发文量
35
审稿时长
12 weeks
期刊最新文献
A 48-month clinical performance of hybrid ceramic fragment restorations manufactured in CAD/CAM in non-carious cervical lesions: case report. Assessment of mechanical allodynia in healthy teeth adjacent and contralateral to endodontically diseased teeth: a clinical study. A global overview of enamel microabrasion for white spot lesions: a bibliometric review. Effect of surface sealant on the color stability and whiteness index of single-shade resin composites after staining and bleaching. Endodontic characteristics of mandibular premolar with dens evaginatus: a retrospective study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1